Schneider-Electric
XY2CE5A296H7TK
Tariff code: 8536508090
This product is discontinued.
Please contact us for possible replacement product options.
Link to the manufacturers site: XY2CE5A296H7TK - ACT FUT DATE APPL TRIP WIRE SWITCH
Main
range of product: Telemecanique Emergency stop rope pull switches XY2C
product or component type: Simple stop rope pull switch
device short name: XY2CE
housing colour: Blue
overvoltage category: Class I conforming to EN/IEC 61140; Class I conforming to NF C 20-030
Complementary
local signalling: Without pilot light
number of cables: 1
trigger cable maximum length: 50 m
bellow material: Nitril
body material: Zamak
cover material: Stainless steel
reset: Without
contacts type and composition: 1 NC + 1 NO
contact operation: Snap action
trigger cable anchor point: LH side
connections - terminals: Screw clamp terminal, 1 x 0.5...2 x 1.5 mm²
tightening torque: 0.8…1.2 N.m
cable entry number: 3 plain hole for Pg 13.5 cable gland
marking: CE
mechanical durability: 60000 cycles
distance between cable supports: 5 m
[Ie] rated operational current: 3 A at 240 V, AC-15, A300 conforming to EN/IEC 60947-5-1 appendix A; 0.27 A at 250 V, DC-13, Q300 conforming to EN/IEC 60947-5-1 appendix A
[Ithe] conventional enclosed thermal current: 10 A
[Ui] rated insulation voltage: 500 V (pollution degree 3) conforming to EN/IEC 60947-1; 300 V conforming to UL 508; 300 V conforming to CSA C22.2 No 14
[Uimp] rated impulse withstand voltage: 6 kV conforming to EN/IEC 60947-1
positive opening: With conforming to EN/IEC 60947-5-1
maximum resistance across terminals: 25 MOhm conforming to EN/IEC 60255-7 category 3; 25 MOhm conforming to NF C 93-050 method A
short-circuit protection: 10 A cartridge fuse type gG conforming to EN/IEC 60269
compatibility code: XY2CE
Environment
standards: EN/IEC 60947-5-1
product certifications: CSA
protective treatment: TC
ambient air temperature for operation: -25…70 °C
ambient air temperature for storage: -40…70 °C
vibration resistance: 10 gn (f= 10…300 Hz) conforming to EN/IEC 60068-2-6
shock resistance: 50 gn 11 ms conforming to EN/IEC 60068-2-27
IP degree of protection: IP66 conforming to IEC 60529
Offer Sustainability
Sustainable offer status: Green Premium product
REACh Regulation: Reference contains Substances of Very High Concern above the threshold
EU RoHS Directive: Pro-active compliance (Product out of EU RoHS legal scope)
Mercury free: Yes
RoHS exemption information: Yes
Environmental Disclosure: ENVPEP111159EN
© 2018 Alplan Kft.