Schneider-Electric
XEND3811
Tariff code:
This product is discontinued.
Please contact us for possible replacement product options.
Link to the manufacturers site: XEND3811 - latching contact block - 1 NC + 1 NO - front mounting, 30 mm centres
Main
range of product: Harmony XAC
product or component type: Contact block
component name: XEND
electrical circuit type: Control circuit
contact block application: Single speed
contact block type: Double
type of operator: Latching
product compatibility: XACM; XACB
mechanical interlocking: Without mechanical interlock
contacts type and composition: 1 NC + 1 NO
mounting of block: Front mounting
contact operation: Slow-break
Complementary
connections - terminals: Screw clamp terminals, 1 x 2.5 mm² with or without cable end; Screw clamp terminals, 2 x 1.5 mm² with or without cable end
mechanical durability: 1000000 cycles
contact code designation: A300 AC-15, Ue = 240 V, Ie = 3 A conforming to IEC 60947-5-1 appendix A; Q300 DC-13, Ue = 250 V, Ie = 0.27 A conforming to IEC 60947-5-1 appendix A
[Ithe] conventional enclosed thermal current: 10 A
[Ui] rated insulation voltage: 500 V (pollution degree 3) conforming to IEC 60947-1
[Uimp] rated impulse withstand voltage: 6 kV conforming to IEC 60947-1
maximum resistance across terminals: 25 MOhm
short-circuit protection: 10 A fuse protection by cartridge fuse type gG
rated operational power in W: 42 W DC-13 for 1000000 cycles, operating rate <60 cyc/mn at 120 V, load factor = 0.5 (inductive load) conforming to IEC 60947-5-1 appendix C; 45 W DC-13 for 1000000 cycles, operating rate <60 cyc/mn at 48 V, load factor = 0.5 (inductive load) conforming to IEC 60947-5-1 appendix C; 60 W DC-13 for 1000000 cycles, operating rate <60 cyc/mn at 24 V, load factor = 0.5 (inductive load) conforming to IEC 60947-5-1 appendix C
rated operational power in VA: 140 VA AC-15 for 1000000 cycles, operating rate <60 cyc/mn at 24 V 50/60 Hz, load factor = 0.5 (inductive load); 385 VA AC-15 for 1000000 cycles, operating rate <60 cyc/mn at 48 V 50/60 Hz, load factor = 0.5 (inductive load); 455 VA AC-15 for 1000000 cycles, operating rate <60 cyc/mn at 230 V 50/60 Hz, load factor = 0.5 (inductive load); 525 VA AC-15 for 1000000 cycles, operating rate <60 cyc/mn at 127 V 50/60 Hz, load factor = 0.5 (inductive load)
terminals description ISO n°1: B; (11-12)NC; (23-24)NO
terminals description ISO n°2: (23-24)NO; (11-12)NC; B
terminal identifier: (13-14)NO; (11-12)NC
net weight: 0.17 kg
Environment
standards: CSA C22.2 No 14; EN 60947-5-1; IEC 60947-5-1
ambient air temperature for operation: -25…70 °C
ambient air temperature for storage: -40…70 °C
vibration resistance: 15 gn (f= 10…500 Hz) conforming to IEC 60068-2-6
shock resistance: 100 gn conforming to IEC 60068-2-27
Offer Sustainability
REACh Regulation: Free of Substances of Very High Concern above the threshold
REACh free of SVHC: Yes
EU RoHS Directive: Pro-active compliance (Product out of EU RoHS legal scope)
Toxic heavy metal free: Yes
Mercury free: Yes
RoHS exemption information: Yes
China RoHS Regulation: X
WEEE: The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins