Skip to main content

Schneider-Electric
XALD324

dark grey station - white flush/red flush/black flush pushbuttons Ø22
Net discounted price 50.77 EUR
Available when ordered (delivery time: 8 working day(s))
Barcode: 3389110114546
Tariff code: 8536508090

Link to the manufacturers site: XALD324 - dark grey station - white flush/red flush/black flush pushbuttons Ø22

Main

Range of produc: Harmony XALD

Product or component type: Complete control station

Device short name: XALD

Product destination: For XB5 Ø 22 mm control and signalling units

Control station application: Three functions

Colour of base of enclosure: Light grey (RAL 7035)

Colour of cover: Dark grey (RAL 7016)

Material: Polycarbonate

Operator profile: 3 flush push-buttons

Operators description: White ''up arrow'' 1 NO - red ''O'' 1 NC - black ''down arrow'' 1 NO

Control station composition: 1 flush push-button, red 1 NC O marking; 1 flush push-button, black 1 NO, white down arrow marking; 1 flush push-button, white 1 NO, black up arrow marking

marking location: Marking on push-button

contact operation: Slow-break

Complementary

Cable entry: 2 knock-outs for cable entry, clamping capacity: 14 mm; 2 knock-outs for Pg 13 cable gland and ISO M20, clamping capacity: 12 mm

Net weight: 0.298 kg

Resistance to high pressure washer: 7000000 Pa at 55 °C, distance : 0.1 m

Colour of marking: White marking when green, red or black caps; Black marking when white caps

Positive opening: With conforming to IEC 60947-5-1 appendix K

Operating travel: 1.5 mm (NC changing electrical state); 2.6 mm (NO changing electrical state); 4.3 mm (total travel)

Operating force: 3.5 N NC changing electrical state; 3.8 N NO changing electrical state

Mechanical durability: 10000000 cycles

Connections - terminals: Screw clamp terminals, <= 2 x 1.5 mm² with cable end conforming to IEC 60947-1; Screw clamp terminals, >= 1 x 0.22 mm² without cable end conforming to IEC 60947-1

Tightening torque: 0.8…1.2 N.m conforming to IEC 60947-1

Shape of screw head: Cross compatible with Philips no 1 screwdriver; Cross compatible with pozidriv No 1 screwdriver; Slotted compatible with flat Ø 4 mm screwdriver; Slotted compatible with flat Ø 5.5 mm screwdriver

Contacts material: Silver alloy (Ag/Ni)

Short-circuit protection: 10 A cartridge fuse type gG conforming to IEC 60947-5-1

[Ith] conventional free air thermal current: 10 A conforming to IEC 60947-5-1

[Ui] rated insulation voltage: 600 V (pollution degree 3) conforming to IEC 60947-1

[Uimp] rated impulse withstand voltage: 6 kV conforming to IEC 60947-1

[Ie] rated operational current: 6 A at 120 V, AC-15, A600 conforming to IEC 60947-5-1; 3 A at 240 V, AC-15, A600 conforming to IEC 60947-5-1; 1.2 A at 600 V, AC-15, A600 conforming to IEC 60947-5-1; 0.55 A at 125 V, DC-13, Q600 conforming to IEC 60947-5-1; 0.27 A at 250 V, DC-13, Q600 conforming to IEC 60947-5-1; 0.1 A at 600 V, DC-13, Q600 conforming to IEC 60947-5-1

Electrical durability: 1000000 cycles, AC-15, 2 A at 230 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to IEC 60947-5-1 appendix C; 1000000 cycles, AC-15, 3 A at 120 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to IEC 60947-5-1 appendix C; 1000000 cycles, AC-15, 4 A at 24 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to IEC 60947-5-1 appendix C; 1000000 cycles, DC-13, 0.2 A at 110 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to IEC 60947-5-1 appendix C; 1000000 cycles, DC-13, 0.5 A at 24 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to IEC 60947-5-1 appendix C

Electrical reliability: Λ < 10exp(-6) at 5 V and 1 mA conforming to IEC 60947-5-4; Λ < 10exp(-8) at 17 V and 5 mA conforming to IEC 60947-5-4

Compatibility code: XALD

Environment

Protective treatment: TH

Ambient air temperature for storage: -40…70 °C

ambient air temperature for operation: -40…70 °C

Electrical shock protection class: Class II conforming to IEC 60536

IP degree of protection: IP66 conforming to IEC 60529; IP69; IP69K; IP67

NEMA degree of protection: NEMA 13; NEMA 4X

IK degree of protection: IK03 conforming to IEC 62262

Standards: CSA C22.2 No 14; IEC 60947-1; IEC 60947-5-4; JIS C8201-5-1; IEC 60947-5-5; UL 508; IEC 60947-5-1; JIS C8201-1

Vibration resistance: 5 gn (f= 12…500 Hz) conforming to IEC 60068-2-6

Shock resistance: 30 gn (duration = 18 ms) for half sine wave acceleration conforming to IEC 60068-2-27; 50 gn (duration = 11 ms) for half sine wave acceleration conforming to IEC 60068-2-27

Packing Units

Unit Type of Package 1: PCE

Number of Units in Package 1: 1

Package 1 Height: 7.1 cm

Package 1 Width: 10.5 cm

Package 1 Length: 14.1 cm

Package 1 Weight: 288.0 g

Unit Type of Package 2: S03

Number of Units in Package 2: 25

Package 2 Height: 30 cm

Package 2 Width: 30 cm

Package 2 Length: 40 cm

Package 2 Weight: 7.683 kg

Offer Sustainability

Sustainable offer status: Green Premium product

REACh Regulation: Free of Substances of Very High Concern above the threshold

REACh free of SVHC: Yes

EU RoHS Directive: Pro-active compliance (Product out of EU RoHS legal scope)

Toxic heavy metal free: Yes

Mercury free: Yes

China RoHS Regulation: X

RoHS exemption information: Yes

Environmental Disclosure: ENVPEP1806010EN

Circularity Profile: ENVEOLI1806010EN

WEEE: The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins

© 2018 Alplan Kft.