Skip to main content

Schneider-Electric
XACS412

spring return contact block - 1 NC - front mounting, 30 or 40 mm centres
Net discounted price 16.75 EUR
In stock: 1 pc(s)
Barcode: 3389110647495
Tariff code: 8536508090

Link to the manufacturers site: XACS412 - spring return contact block - 1 NC - front mounting, 30 or 40 mm centres

Main

Range of produc: Harmony XAC

Product or component type: Contact block

component name: XACS

Electrical circuit type: Control circuit

Contact block type: Single

Type of operator: Spring return

Product compatibility: XACA; ZA2B... head

Mechanical interlocking: Without mechanical interlock

Contacts type and composition: 1 NC

Mounting of block: Front mounting

contact operation: Slow-break

Complementary

Connections - terminals: Screw clamp terminals, 1 x 2.5 mm² with or without cable end; Screw clamp terminals, 2 x 1.5 mm² with or without cable end

Horizontal fixing centres: 40 mm

Vertical fixing centres: 30 mm

Mechanical durability: 1000000 cycles

Contact code designation: A300 AC-15, Ue = 240 V, Ie = 3 A conforming to IEC 60947-5-1 appendix A; Q300 DC-13, Ue = 250 V, Ie = 0.27 A conforming to IEC 60947-5-1 appendix A

[Ithe] conventional enclosed thermal current: 10 A

[Ui] rated insulation voltage: 500 V (pollution degree 3) conforming to IEC 60947-1

[Uimp] rated impulse withstand voltage: 6 kV conforming to IEC 60947-1

Maximum resistance across terminals: 25 MOhm

Short-circuit protection: 10 A fuse protection by cartridge fuse type gG

Rated operational power in W: 42 W DC-13 for 1000000 cycles, operating rate <60 cyc/mn at 120 V, load factor = 0.5 (inductive load) conforming to IEC 60947-5-1 appendix C; 45 W DC-13 for 1000000 cycles, operating rate <60 cyc/mn at 48 V, load factor = 0.5 (inductive load) conforming to IEC 60947-5-1 appendix C; 60 W DC-13 for 1000000 cycles, operating rate <60 cyc/mn at 24 V, load factor = 0.5 (inductive load) conforming to IEC 60947-5-1 appendix C

Rated operational power in VA: 140 VA AC-15 for 1000000 cycles, operating rate <60 cyc/mn at 24 V 50/60 Hz, load factor = 0.5 (inductive load); 385 VA AC-15 for 1000000 cycles, operating rate <60 cyc/mn at 48 V 50/60 Hz, load factor = 0.5 (inductive load); 455 VA AC-15 for 1000000 cycles, operating rate <60 cyc/mn at 230 V 50/60 Hz, load factor = 0.5 (inductive load); 525 VA AC-15 for 1000000 cycles, operating rate <60 cyc/mn at 127 V 50/60 Hz, load factor = 0.5 (inductive load)

Terminals description ISO n°1: (11-12)NC

Terminal identifier: (13-14)NO; (11-12)NC

Net weight: 0.07 kg

Environment

Standards: IEC 60947-5-1; CSA C22.2 No 14; IEC 60947-5-1

ambient air temperature for operation: -25…70 °C

Ambient air temperature for storage: -40…70 °C

Vibration resistance: 15 gn (f= 10…500 Hz) conforming to IEC 60068-2-6

Shock resistance: 100 gn conforming to IEC 60068-2-27

Packing Units

Unit Type of Package 1: PCE

Number of Units in Package 1: 1

Package 1 Height: 3.1 cm

Package 1 Width: 7.3 cm

Package 1 Length: 9.8 cm

Package 1 Weight: 58.0 g

Unit Type of Package 2: S01

Number of Units in Package 2: 30

Package 2 Height: 15.0 cm

Package 2 Width: 15.0 cm

Package 2 Length: 40.0 cm

Package 2 Weight: 1.795 kg

Offer Sustainability

REACh Regulation: Free of Substances of Very High Concern above the threshold

REACh free of SVHC: Yes

EU RoHS Directive: Pro-active compliance (Product out of EU RoHS legal scope)

Toxic heavy metal free: Yes

Mercury free: Yes

China RoHS Regulation: X

RoHS exemption information: Yes

WEEE: The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins

© 2018 Alplan Kft.