Skip to main content

Schneider-Electric
METSEION95040

ION9000T meter, HSTC, DIN mount, 192 mm display
Net discounted price 8,145.52 EUR
In stock: 3 pc(s)
Barcode: 3606481352354
Tariff code: 9028309000

Link to the manufacturers site: METSEION95040 - ION9000T meter, HSTC, DIN mount, 192 mm display

Main

Range: PowerLogic

Product name: PowerLogic ION9000

Device short name: ION95040

Product or component type: Energy and power quality meter

Device application: Power monitoring; WAGES metering; Net metering; Medium voltage; High voltage

Metering type: Demand current I1, I2, I3, I4, I5; Peak demand currents; Demand power P, Q, S; Peak demand power PM, QM, SM; Calculated active and reactive energy (+/- W.h, +/- VAR.h)

provided equipment: Remote display; Remote display adapter; Mounting instructions; Mounting hardware

Complementary

Power quality analysis: EN 50160 compliance checking; conforming to IEEE 519 harmonic limit; conforming to IEC 61000-4-30: class A compliance reporting; conforming to IEEE 519 compliance reporting; waveform capture; total demand distortion; total harmonic distortion; up to the 63rd harmonic; up to the 127th harmonic with software; disturbance direction detection; dip, swell and transient; half cycle data acquisition; high-speed transient capture; coincidence disturbance waveform capture; transient detection (100 ns)

Type of measurement: Voltage sags and swells; Current sags and swells; Voltage; Current; Frequency; Active and reactive power total; Apparent power total; Active and reactive power per phase; Apparent power per phase; Power factor total; Power factor per phase; Active and reactive energy; Apparent energy; Harmonic distorsion (I THD & U THD)

[Us] rated supply voltage: 90...480 V AC 45...66 Hz +/- 10 %; 90...120 V AC 400 Hz +/- 10 %; 110...480 V DC +/- 15 %

Network frequency: 50 Hz; 60 Hz

Ride-through time: 100 ms 6 cycles at 60 Hz 120 V AC typical; 400 ms 24 cycles at 60 Hz 240 V AC typical; 1200 ms 72 cycles at 60 Hz 480 V AC typical

[In] rated current: 1 A; 5 A

Poles description: 3P + N + E

Power consumption in VA: 38 VA at 480 V AC

Display resolution: 800 x 480 pixels

Display type: Remote LCD display; Colour touchscreen

Sampling rate: 1024 samples/cycle

Measurement current: 0.01…20 A

Analogue input type: Voltage (impedance 5 MOhm); External CT (impedance 0.3 mOhm)5 x

Measurement voltage: 57…400 V AC 42...69 Hz between phase and neutral; 100…690 V AC 42...69 Hz between phases; 10 kV AC transient

Frequency measurement range: 20…450 Hz

Number of inputs: 8 digital 30 V AC/60 V DC

Measurement accuracy: Voltage +/- 0.1 %; Current +/- 0.1 %

Accuracy class: Class 0.1S active energy conforming to IEC 62053-22; Class 0.1 active energy conforming to IEC 61557-12; Class 0.1 active energy conforming to ANSI C12.20; Class 0.5S reactive energy conforming to IEC 62053-24; Class 0.1 current conforming to IEC 61557-12; Class 0.1 voltage conforming to IEC 61557-12; Class 0.1 active power conforming to IEC 61557-12; Class 0.5 power factor conforming to IEC 61557-12

Number of outputs: 4 digital; 2 form C relay output

Communication port protocol: Modbus RTU at 2400...115200 bps - 2-wire; ION at 2400...115200 bps - 2-wire; DNP3 at 2400...115200 bps - 2-wire; Modbus TCP at 10/100 Mbit/s; ION TCP at 10/100 Mbit/s; DNP3 TCP at 10/100 Mbit/s; IEC 61850; Ethernet Modbus TCP/IP daisy chain at 10/100 Mbit/s; DHCP; DNS; DLMS

Communication port support: RS485 2 removable screw terminal block

Port Ethernet: 10/100BASE-TX 2 RJ45

communication gateway: Ethernet/serial

Time synchronisation protocol: GPS; IRIG-B; NTP; SNTP; PTP

data recording: Time stamping; Min/max of instantaneous values; User-definable data logs; Continuous logging or snapshot; Trending/forecasting; Event logs; Alarm logs; Configuration change; Power outage; User login/logout; Data logs; GPS synchronisation; Sequence of event recording

memory capacity: 2 GB

Cybersecurity: Syslog protocol support; Robust security logs; Port hardening; Enable/disable communication ports; Hardware metrology lock

Web services: Viewing of captured waveform; Web page; Pass/fail report for IEEE 519; Pass/fail report for EN 50160; ITIC (CBEMA) curve; SEMI curve; NEMA motor derating curve; Alarm notification by e-mail; TLS 1.2; Push historical data via mail

Ethernet service: DHCP client; Device Profile Web Services (DPWS); Rapid Scanning Tree Protocol (RSTP); FTP/HTTP/HTTPS

Communication service: Compliant reports; Power quality summary; Energy report; EcoStruxure Power Events Analysis; SMTP e-mail notification; SNMP

Tamperproof of settings: Protected by sealable cover

Mounting support: DIN rail meter device; Door cut-out remote display

Electrical insulation class: Class III conforming to EN/IEC 62052-11

Isolation voltage: III400…690 V conforming to EN 61010-1:ed. 3; III347…600 V conforming to UL 61010-1:ed. 3; III347…600 V conforming to CSA C22.2 No 61010-1:ed. 3

Width: 160 mm

Depth: 135.3 mm

height: 160 mm

Net weight: 1.5 kg

Market segment: Data center; Healthcare; Semiconductor; Pharmaceutical; Chemical; Energy; Mining

Environment

Electromagnetic compatibility: EMC immunity conforming to IEC 62052-11; EMC immunity conforming to IEC 61326-1; EMC immunity conforming to IEC 61000-6-5; Electrostatic discharge immunity test conforming to IEC 61000-4-2; Immunity to radiated fields conforming to IEC 61000-4-3; Immunity to fast transients conforming to IEC 61000-4-4; Surge immunity test conforming to IEC 61000-4-5; Immunity to conducted disturbances conforming to IEC 61000-4-6; Immunity to magnetic fields at network frequency conforming to IEC 61000-4-8; Immunity to conducted disturbances - test level: 2...150 kHz conforming to CLC/TR 50579; Voltage dips and interruptions immunity test conforming to IEC 61000-4-11; Immunity to impulse waves conforming to IEC 61000-4-12; Conducted and radiated emissions conforming to EN 55011; Conducted and radiated emissions class B conforming to EN 55032; Conducted and radiated emissions class B conforming to FCC part 15; Conducted and radiated emissions class B conforming to ICES-003; Surge withstand conforming to ANSI C37.90.1; Surge withstand conforming to IEEE C37.90.1

IP degree of protection: IP65 front: ; IP30 rear:

Degree of protection: UL type 12, front

Relative humidity: 5…95 %

Ambient air temperature for operation: -25…70 °C

Ambient air temperature for storage: -40…85 °C

installation category: III

Operating altitude: 0...3000 m

Standards: ANSI C12.20; ANSI C37.90.1; IEC 61000-4-15; IEC 61000-4-30; IEC 61010-1; IEC 61326-1; IEC 61557-12; IEC 61850; IEC 62052-11; IEC 62052-31; IEC 62053-22; IEC 62053-23; IEC 62053-24; IEC 62586; UL 61010-1

Quality labels: ISO 9001; ISO 14000

Packing Units

Unit Type of Package 1: PCE

Number of Units in Package 1: 1

Package 1 Height: 29.5 cm

Package 1 Width: 26.4 cm

Package 1 Length: 37.8 cm

Package 1 Weight: 3.6 kg

Offer Sustainability

Sustainable offer status: Green Premium product

REACh Regulation: Reference contains Substances of Very High Concern above the threshold

EU RoHS Directive: Compliant with Exemptions

Mercury free: Yes

China RoHS Regulation: X

RoHS exemption information: Yes

Environmental Disclosure: ENVPEP1801009EN

Circularity Profile: ENVEOLI1801009EN

WEEE: The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins