Schneider-Electric
LUCBX6FU
Tariff code: 8537109899
Link to the manufacturers site: LUCBX6FU - advanced control unit LUCB - class 10 - 0.15...0.6 A - 110...220 V DC/AC
Main
Range: TeSys
Range of produc: TeSys Ultra
Product name: TeSys Ultra
Device short name: LUCB
Product or component type: Advanced control unit
Device application: Motor control; Motor protection
Product specific application: Basic protection and advanced functions, communication
Function available: Manual reset; Protection against phase failure and phase imbalance; Protection against overload and short-circuit; Earth fault protection
Product compatibility: Power base LUB12; Power base LUB32; Power base LUB38; Power base LUB120; Power base LUB320; Power base LUB380; Reversing contactor breaker LU2B12FU; Reversing contactor breaker LU2B32FU; Reversing contactor breaker LU2B38FU
[Ue] rated operational voltage: 690 V AC
Network frequency: 40...60 Hz
Load type: 3-phase motor - cooling: self-cooled
utilisation category: AC-44; AC-43; AC-41
Motor power kW: 0.09 kW at 400...440 V AC 50/60 Hz
Thermal protection adjustment range: 0.15…0.6 A
Thermal overload class: Class 10 - frequency limit: 40…60 Hz - temperature compensation: -25…70 °C conforming to IEC 60947-6-2; Class 10 - frequency limit: 40…60 Hz - temperature compensation: -25…70 °C conforming to UL 508
Tripping threshold: 14.2 x Ir +/- 20 %
Phase failure sensitivity: Yes
[Uc] control circuit voltage: 110...240 V AC; 110...220 V DC
Complementary
Control circuit voltage limits: 88...264 V for AC circuit 110...240 V in operation; 88...242 V for DC circuit 110...220 V in operation; 55 V for AC circuit 110...240 V drop-out; 55 V for DC circuit 110...220 V drop-out
Typical current consumption: 280 mA at 110...240 V AC I maximum while closing with LUB12; 280 mA at 110...240 V AC I maximum while closing with LUB32; 280 mA at 110...240 V AC I maximum while closing with LUB38; 280 mA at 110...220 V DC I maximum while closing with LUB12; 280 mA at 110...220 V DC I maximum while closing with LUB32; 280 mA at 110...220 V DC I maximum while closing with LUB38; 35 mA at 110...240 V AC I rms sealed with LUB12; 25 mA at 110...240 V AC I rms sealed with LUB32; 25 mA at 110...240 V AC I rms sealed with LUB38; 35 mA at 110...220 V DC I rms sealed with LUB12; 25 mA at 110...220 V DC I rms sealed with LUB32; 25 mA at 110...220 V DC I rms sealed with LUB38
Heat dissipation: 2 W for control circuit with LUB12; 3 W for control circuit with LUB32; 3 W for control circuit with LUB38
Operating time: 35 ms opening with LUB12 for control circuit; 35 ms opening with LUB32 for control circuit; 35 ms opening with LUB38 for control circuit; 50 ms closing with LUB12 for control circuit; 50 ms closing with LUB32 for control circuit; 50 ms closing with LUB38 for control circuit
Reset: Manual reset
Standards: EN 60947-6-2; IEC 60947-6-2; UL 60947-4-1, with phase barrier; CSA C22.2 No 60947-4-1, with phase barrier
product certifications: CE; UL; CSA; CCC; EAC; ASEFA; ATEX; Marine
[Ui] rated insulation voltage: 690 V conforming to IEC 60947-6-2; 600 V conforming to UL 60947-4-1; 600 V conforming to CSA C22.2 No 60947-4-1
[Uimp] rated impulse withstand voltage: 6 kV conforming to IEC 60947-6-2
Safe separation of circuit: 400 V SELV between the control and auxiliary circuits conforming to IEC 60947-1; 400 V SELV between the control or auxiliary circuit and the main circuit conforming to IEC 60947-1
Fixing mode: Plug-in (front face)
Width: 45 mm
height: 66 mm
Depth: 60 mm
Compatibility code: LUCB
Environment
IP degree of protection: IP20 front panel and wired terminals conforming to IEC 60947-1; IP20 other faces conforming to IEC 60947-1; IP40 front panel outside connection zone conforming to IEC 60947-1
Protective treatment: TH conforming to IEC 60068
Ambient air temperature for operation: -25…70 °C
Ambient air temperature for storage: -40…85 °C
Operating altitude: 2000 m
Fire resistance: 960 °C parts supporting live components conforming to IEC 60695-2-12; 650 °C conforming to IEC 60695-2-12
Shock resistance: 10 gn power poles open conforming to IEC 60068-2-27; 15 gn power poles closed conforming to IEC 60068-2-27
Vibration resistance: 2 gn, 5…300 Hz, power poles open conforming to IEC 60068-2-6; 4 gn, 5…300 Hz, power poles closed conforming to IEC 60068-2-6
Resistance to electrostatic discharge: 8 kV level 3 in open air conforming to IEC 61000-4-2; 8 kV level 4 on contact conforming to IEC 61000-4-2
Non-dissipating shock wave: 1 kV serial mode conforming to IEC 60947-6-2; 2 kV common mode conforming to IEC 60947-6-2
Resistance to radiated fields: 10 V/m 3 conforming to IEC 61000-4-3
Resistance to fast transients: 2 kV class 3 serial link conforming to IEC 61000-4-4; 4 kV class 4 all circuits except for serial link conforming to IEC 61000-4-4
Immunity to radioelectric fields: 10 V conforming to IEC 61000-4-6
Immunity to microbreaks: 3 ms
Immunity to voltage dips: 70 % / 500 ms conforming to IEC 61000-4-11
Packing Units
Unit Type of Package 1: PCE
Number of Units in Package 1: 1
Package 1 Height: 5.2 cm
Package 1 Width: 8.5 cm
Package 1 Length: 10.3 cm
Package 1 Weight: 128.0 g
Unit Type of Package 2: S01
Number of Units in Package 2: 9
Package 2 Height: 15.0 cm
Package 2 Width: 15.0 cm
Package 2 Length: 40.0 cm
Package 2 Weight: 1.306 kg
Offer Sustainability
Sustainable offer status: Green Premium product
REACh Regulation: Reference contains Substances of Very High Concern above the threshold
EU RoHS Directive: Compliant with Exemptions
Mercury free: Yes
China RoHS Regulation: Product out of China RoHS scope. Substance declaration for your information
RoHS exemption information: Yes
Environmental Disclosure: ENVPEP080204EN
Circularity Profile: ENVEOLI100414
WEEE: The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
PVC free: Yes
Halogen content performance: Halogen free plastic parts product
© 2018 Alplan Kft.