LU2BB0ES

power base - TeSys U - 32 A - 48...72 V DC - no connections control
Barcode: 3389110363159
Tariff code:

This product is discontinued.

Please contact us for possible replacement product options.

Link to the manufacturers site: LU2BB0ES - power base - TeSys U - 32 A - 48...72 V DC - no connections control

Main

range of product: TeSys U

range: TeSys

product name: TeSys U

device short name: LU2B

product or component type: Reversing power base

device application: Motor control; Motor protection

product compatibility: Control unit LUC.X6ES; Control unit LUC.1XES; Control unit LUC.05ES; Control unit LUC.12ES; Control unit LUC.18ES; Control unit LUC.32ES

poles description: 3P

suitability for isolation: Yes

[Ue] rated operational voltage: 690 V AC for power circuit

network frequency: 40...60 Hz

[Ith] conventional free air thermal current: 32 A

[Ie] rated operational current: 28.5 A at <= 440 V; 23 A at 500 V; 21 A at 690 V

utilisation category: AC-43; AC-44; AC-41

[Ics] rated service breaking capacity: 50 kA at 230 V; 50 kA at 440 V; 10 kA at 500 V; 4 kA at 690 V

auxiliary contact composition: 1 NO + 1 NC

auxiliary contacts type: type linked contacts (1 NO + 1 NC) conforming to IEC 60947-4-1; type mirror contact (1 NC) conforming to IEC 60947-1

[Uc] control circuit voltage: 48...72 V AC 50/60 Hz; 48...72 V DC

control circuit voltage limits: 29 V AC drop-out; 29 V DC drop-out; 38.5...72 V AC in operation; 38.5...93 V DC in operation

Complementary

typical current consumption: 2300 mA at 48...72 V DC I maximum while closing; 2300 mA at 48...72 V AC I maximum while closing

heat dissipation: 3 W for control circuit with LUCA, LUCB, LUCC, LUCD; 1.8 W for control circuit with LUCM

inrush restraint duration: 25 ms AC 50/60 Hz; 15 ms DC

safety reliability level: B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1; B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1

operating time: 150 ms with change of direction for power circuit; 35 ms opening for control circuit; 75 ms without change of direction for power circuit; 60 ms closing for control circuit

mechanical durability: 15 Mcycles

maximum operating rate: 3600 cyc/h

product certifications: CE; UL; CSA; CCC; EAC; ASEFA; ATEX; Marine

standards: EN 60947-6-2; IEC 60947-6-2; UL 60947-4-1, with phase barrier; CSA C22.2 No 60947-4-1, with phase barrier

[Ui] rated insulation voltage: 690 V conforming to IEC 60947-6-2 (pollution degree 3); 600 V conforming to UL 60947-4-1; 600 V conforming to CSA C22.2 No 60947-4-1

[Uimp] rated impulse withstand voltage: 6 kV conforming to IEC 60947-6-2

safe separation of circuit: 400 V SELV between the control and auxiliary circuits conforming to IEC 60947-1 appendix N; 400 V SELV between the control or auxiliary circuit and the main circuit conforming to IEC 60947-1 appendix N

fixing mode: Clipped (DIN rail); Screw-fixed (plate)

connections - terminals: Power circuit: screw clamp terminals 1 cable(s) 1…10 mm² rigid; Power circuit: screw clamp terminals 1 cable(s) 1…6 mm² flexible with cable end; Power circuit: screw clamp terminals 1 cable(s) 2.5…10 mm² flexible without cable end; Power circuit: screw clamp terminals 2 cable(s) 1…6 mm² flexible with cable end; Power circuit: screw clamp terminals 2 cable(s) 1…6 mm² rigid; Power circuit: screw clamp terminals 2 cable(s) 1.5…6 mm² flexible without cable end; Control circuit: without connection

tightening torque: Power circuit: 1.9…2.5 N.m flat screwdriver 6 mm; Power circuit: 1.9…2.5 N.m Philips No 2 screwdriver 6 mm

width: 45 mm

height: 224 mm

depth: 126 mm

net weight: 1.25 kg

compatibility code: LU2B

Environment

IP degree of protection: IP20 conforming to IEC 60947-1 (front panel and wired terminals); IP20 conforming to IEC 60947-1 (other faces); IP40 conforming to IEC 60947-1 (front panel outside connection zone)

protective treatment: TH conforming to IEC 60068

ambient air temperature for operation: -25…60 °C with LUCM; -25…70 °C with LUCA, LUCB, LUCC, LUCD

ambient air temperature for storage: -40…85 °C

fire resistance: 960 °C parts supporting live components conforming to IEC 60695-2-12; 650 °C conforming to IEC 60695-2-12

operating altitude: 2000 m

shock resistance: 10 gn power poles open conforming to IEC 60068-2-27; 15 gn power poles closed conforming to IEC 60068-2-27

vibration resistance: 2 gn (f= 5…300 Hz) power poles open conforming to IEC 60068-2-27; 4 gn (f= 5…300 Hz) power poles closed conforming to IEC 60068-2-27

resistance to electrostatic discharge: 8 kV level 3 in open air conforming to IEC 61000-4-2; 8 kV level 4 on contact conforming to IEC 61000-4-2

resistance to radiated fields: 10 V/m 3 conforming to IEC 61000-4-3

resistance to fast transients: 2 kV class 3 serial link conforming to IEC 61000-4-4; 4 kV class 4 all circuits except for serial link conforming to IEC 61000-4-4

non-dissipating shock wave: 1 kV serial mode conforming to IEC 60947-6-2; 2 kV common mode conforming to IEC 60947-6-2

immunity to radioelectric fields: 10 V conforming to IEC 61000-4-6

immunity to microbreaks: 3 ms for control circuit

immunity to voltage dips: 70 % / 500 ms conforming to IEC 61000-4-11

Offer Sustainability

EU RoHS Directive: Compliant

Mercury free: Yes

RoHS exemption information: Yes

China RoHS Regulation: Product out of China RoHS scope. Substance declaration for your information

WEEE: The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins

© 2018 Alplan Kft.