Schneider-Electric
LC2D50AEHE
Tariff code: 8536490099
Link to the manufacturers site: LC2D50AEHE - TeSys D reversing contactor - 3P - <= 440 V - 50 A AC-3 - 48...130 V AC/DC coil
Main
Range of produc: TeSys Deca
Range: TeSys; TeSys Deca
Product name: Tesys Deca green; TeSys Deca
Product or component type: Reversing contactor
Device short name: LC2D
contactor application: Resistive load; Motor control
utilisation category: AC-1; AC-3
device presentation: Preassembled with reversing power busbar
Poles description: 3P
Pole contact composition: 3 NO
[Ue] rated operational voltage: Power circuit: 690 V AC 25...400 Hz
[Ie] rated operational current: 50 A (at <60 °C) at <= 440 V AC-3 for power circuit; 80 A (at <60 °C) at <= 440 V AC-1 for power circuit
Motor power kW: 15 kW at 220...230 V AC 50 Hz; 22 kW at 380...400 V AC 50 Hz; 25 kW at 415 V AC 50 Hz; 30 kW at 440 V AC 50 Hz; 30 kW at 500 V AC 50 Hz; 33 kW at 660...690 V AC 50 Hz
Motor power hp: 3 hp at 115 V AC 60 Hz for 1 phase motors; 7.5 hp at 230/240 V AC 60 Hz for 1 phase motors; 15 hp at 200/208 V AC 60 Hz for 3 phases motors; 15 hp at 230/240 V AC 60 Hz for 3 phases motors; 40 hp at 460/480 V AC 60 Hz for 3 phases motors; 40 hp at 575/600 V AC 60 Hz for 3 phases motors
Control circuit type: AC at 50/60 Hz AC/DC electronic; DC AC/DC electronic
[Uc] control circuit voltage: 48...130 V AC 50/60 Hz; 48...130 V DC
Auxiliary contact composition: 1 NO + 1 NC
[Uimp] rated impulse withstand voltage: 6 kV conforming to IEC 60947
Overvoltage category: III
[Ith] conventional free air thermal current: 10 A (at 60 °C) for signalling circuit; 80 A (at 60 °C) for power circuit
Irms rated making capacity: 140 A AC for signalling circuit conforming to IEC 60947-5-1; 250 A DC for signalling circuit conforming to IEC 60947-5-1; 900 A at 440 V for power circuit conforming to IEC 60947
Rated breaking capacity: 900 A at 440 V for power circuit conforming to IEC 60947
[Icw] rated short-time withstand current: 100 A - 1 s for signalling circuit; 120 A - 500 ms for signalling circuit; 140 A - 100 ms for signalling circuit; 400 A 40 °C - 10 s for power circuit; 810 A 40 °C - 1 s for power circuit; 84 A 40 °C - 10 min for power circuit; 208 A 40 °C - 1 min for power circuit
Associated fuse rating: 10 A gG for signalling circuit conforming to IEC 60947-5-1; 100 A gG at <= 690 V coordination type 1 for power circuit; 100 A gG at <= 690 V coordination type 2 for power circuit
Average impedance: 1.5 mOhm - Ith 80 A 50 Hz for power circuit
[Ui] rated insulation voltage: Power circuit: 690 V conforming to IEC 60947-4-1; Signalling circuit: 690 V conforming to IEC 60947-1
Electrical durability: 1.8 Mcycles 42 A AC-3 at Ue <= 440 V; 0.5 Mcycles 80 A AC-1 at Ue <= 440 V
Power dissipation per pole: 3.7 W AC-3; 9.6 W AC-1
Protective cover: With
Interlocking type: Mechanical
mounting support: Rail; Plate
Standards: EN/IEC 60947-4-1; EN/IEC 60947-5-1; UL 60947-4-1; CSA C22.2 No 60947-4-1; IEC 60335-1
Product certifications: CCC; CSA; EAC; UL; KC; DNV-GL; LROS (Lloyds register of shipping); UKCA
Connections - terminals: Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible without cable end; Control circuit: screw clamp terminals 2 cable(s) 1…4 mm²flexible without cable end; Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible with cable end; Control circuit: screw clamp terminals 2 cable(s) 1…2.5 mm²flexible with cable end; Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²solid; Control circuit: screw clamp terminals 2 cable(s) 1…4 mm²solid; Power circuit: EverLink BTR screw connectors 1 cable(s) 1…35 mm²flexible without cable end; Power circuit: EverLink BTR screw connectors 2 cable(s) 1…25 mm²flexible without cable end; Power circuit: EverLink BTR screw connectors 1 cable(s) 1…35 mm²flexible with cable end; Power circuit: EverLink BTR screw connectors 2 cable(s) 1…25 mm²flexible with cable end; Power circuit: EverLink BTR screw connectors 1 cable(s) 1…35 mm²solid; Power circuit: EverLink BTR screw connectors 2 cable(s) 1…25 mm²solid
Tightening torque: Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm; Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver Philips No 2; Power circuit: 8 N.m - on EverLink BTR screw connectors - cable 25…35 mm² hexagonal screw head 4 mm; Power circuit: 5 N.m - on EverLink BTR screw connectors - cable 1…25 mm² hexagonal screw head 4 mm
Operating time: 55...65 ms closing; 20...120 ms opening (date code >= 17221); 20...80 ms opening (date code >= 18011)
Safety reliability level: B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1; B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
Mechanical durability: 6 Mcycles
Maximum operating rate: 3600 cyc/h 60 °C
Complementary
Coil technology: Built-in bidirectional peak limiting
Control circuit voltage limits: <= 0.1 Uc (-40…70 °C):drop-out AC/DC; 0.85...1.1 Uc (-40…60 °C):operational AC/DC; 1...1.1 Uc (60…70 °C):operational AC/DC
Inrush power in VA: 23 VA 50/60 Hz (at 20 °C)
Inrush power in W: 19 W at 20 °C
Hold-in power consumption in VA: 1.4 VA (at 20 °C) 50/60 Hz
Hold-in power consumption in W: 0.9 W at 20 °C
Heat dissipation: 0.9 W at 50/60 Hz
Auxiliary contacts type: type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1; type mirror contact 1 NC conforming to IEC 60947-4-1
Signalling circuit frequency: 25...400 Hz
Minimum switching current: 5 mA for signalling circuit
Minimum switching voltage: 17 V for signalling circuit
Non-overlap time: 1.5 ms on de-energisation between NC and NO contact; 1.5 ms on energisation between NC and NO contact
Insulation resistance: > 10 MOhm for signalling circuit
Compatibility code: LC2D
Environment
IP degree of protection: IP20 front face conforming to IEC 60529
Climatic withstand: conforming to IACS E10; conforming to IEC 60947-1 Annex Q category D
Protective treatment: TH conforming to IEC 60068-2-30
Pollution degree: 3
Ambient air temperature for operation: -40…60 °C; 60…70 °C with derating
Ambient air temperature for storage: -60…80 °C
Operating altitude: 0...3000 m
Fire resistance: 850 °C conforming to IEC 60695-2-1
Flame retardance: V1 conforming to UL 94
Mechanical robustness: Vibrations contactor open: 2 Gn, 5...300 Hz; Vibrations contactor closed: 4 Gn, 5...300 Hz; Shocks contactor open: 10 Gn for 11 ms; Shocks contactor closed: 15 Gn for 11 ms
height: 122 mm
Width: 119 mm
Depth: 120 mm
Net weight: 2.164 kg
Colour: Grey (SE GREY 6); Green (SE GREEN 2)
Packing Units
Unit Type of Package 1: PCE
Number of Units in Package 1: 1
Package 1 Height: 14.0 cm
Package 1 Width: 16.2 cm
Package 1 Length: 19.8 cm
Package 1 Weight: 2.281 kg
Unit Type of Package 2: S03
Number of Units in Package 2: 4
Package 2 Height: 30.0 cm
Package 2 Width: 30.0 cm
Package 2 Length: 40.0 cm
Package 2 Weight: 10.003 kg
Offer Sustainability
Sustainable offer status: Green Premium product
REACh Regulation: Reference contains Substances of Very High Concern above the threshold
EU RoHS Directive: Compliant with Exemptions
Mercury free: Yes
China RoHS Regulation: Product out of China RoHS scope. Substance declaration for your information
RoHS exemption information: Yes
Environmental Disclosure: ENVPEP1607010EN
Circularity Profile: ENVEOLI1607010EN
WEEE: The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
Halogen content performance: Halogen free plastic parts & cables product
© 2018 Alplan Kft.