Schneider-Electric
LC1F3304
Tariff code:
This product is discontinued.
Please contact us for possible replacement product options.
Link to the manufacturers site: LC1F3304 - TeSys F contactor - 4P(4 NO) - AC-1 - <= 440 V 400 A - without coil
Main
range of product: TeSys F
range: TeSys
product name: TeSys F
product or component type: Contactor
device short name: LC1F
contactor application: Resistive load
utilisation category: AC-1
poles description: 4P
pole contact composition: 4 NO
[Ue] rated operational voltage: <= 1000 V AC 50/60 Hz; <= 460 V DC
[Ie] rated operational current: 400 A (at <40 °C) at <= 440 V AC AC-1
Complementary
[Uc] control circuit voltage: 24...1000 V AC 40...400 Hz with LX1/LX9 coil; 24...460 V DC with LX4 coil; 100...250 V AC 50/60 Hz with LXE coil; 100...380 V DC with LXE coil
[Uimp] rated impulse withstand voltage: 8 kV
overvoltage category: III
[Ith] conventional free air thermal current: 400 A (at 40 °C)
Irms rated making capacity: 3300 A AC conforming to IEC 60947-4-1
rated breaking capacity: 2640 A conforming to IEC 60947-4-1
[Icw] rated short-time withstand current: 2650 A 40 °C - 10 s; 1800 A 40 °C - 30 s; 1300 A 40 °C - 1 min; 900 A 40 °C - 3 min; 750 A 40 °C - 10 min
associated fuse rating: 400 A aM at <= 440 V; 500 A gG at <= 440 V
average impedance: 0.28 mOhm - Ith 400 A 50 Hz
[Ui] rated insulation voltage: 1000 V conforming to IEC 60947-4-1; 1500 V conforming to VDE 0110 group C
control circuit voltage limits: Operational: 0.85...1.1 Uc AC 40...400 Hz with LX1/LX9 coil; Drop-out: 0.35...0.55 Uc AC 40...400 Hz with LX1/LX9 coil; Operational: 0.85...1.1 Uc DC with LX4 coil; Drop-out: 0.15...0.2 Uc DC with LX4 coil; Operational: 85...275 V AC 50/60 Hz with LXE coil; Drop-out: 0...60 V AC 50/60 Hz with LXE coil; Operational: 85...418 V DC with LXE coil; Drop-out: 0...45 V DC with LXE coil
power dissipation per pole: 44 W AC-1
heat dissipation: 8 W; 2.2…5.5 W
operating time: 40...65 ms closing for with LX1/LX9 coil; 100...170 ms opening for with LX1/LX9 coil; 40...50 ms closing for with LX4 coil; 40...65 ms opening for with LX4 coil; 40...80 ms closing for with LXE coil; 6...54 ms opening for with LXE coil
mounting support: Plate
standards: IEC 60947-4-1; JIS C8201-4-1; EN 60947-1; IEC 60947-1; EN 60947-4-1
product certifications: ABS; CSA; UL; RMRoS; DNV; CB; BV; LROS (Lloyds register of shipping); RINA; UKCA
connections - terminals: Power circuit: lugs-ring terminals 1 cable(s) 240 mm²; Power circuit: bar 2 cable(s) - busbar cross section: 30 x 5 mm; Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible without cable end; Control circuit: screw clamp terminals 2 cable(s) 1…4 mm²flexible with cable end; Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible with cable end; Control circuit: screw clamp terminals 2 cable(s) 1…2.5 mm²solid without cable end; Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²; Control circuit: screw clamp terminals 2 cable(s) 1…4 mm²; Control circuit: screw clamp terminals 1.0 cable(s) 0.2…2.5 mm²flexible without cable end; Control circuit: screw clamp terminals 1.0 cable(s) 0.25…2.5 mm²flexible with cable end; Control circuit: screw clamp terminals 1.0 cable(s) 0.2…2.5 mm²solid without cable end
tightening torque: Power circuit: 35 N.m; Control circuit: 1.2 N.m; Control circuit: 0.6 N.m
mechanical durability: 10 Mcycles
inrush power in VA: 600…700 VA, 40...400 Hz cos phi 0.9 (at 20 °C)with LX1/LX9 coil; 655…803 VA (at 20 °C)with LX4 coil; 300…350 VA, 50/60 Hz cos phi 0.5 (at 20 °C)with LXE coil; 300…310 VA (at 20 °C)with LXE coil
hold-in power consumption in VA: 8…10 VA, 40...400 Hz cos phi 0.9 (at 20 °C)with LX1/LX9 coil; 3.68…4.53 VA (at 20 °C)with LX4 coil; 4.5…7.0 VA, 50/60 Hz cos phi 0.5 (at 20 °C)with LXE coil; 2.5…4.0 VA (at 20 °C)with LXE coil
maximum operating rate: 2400 cyc/h 55 °C
compatibility code: LC1F
Environment
IP degree of protection: IP20 front face with shrouds conforming to IEC 60529; IP20 front face with shrouds conforming to VDE 0106
protective treatment: TH
ambient air temperature for operation: -5…55 °C
ambient air temperature for storage: -60…80 °C
permissible ambient air temperature around the device: -40…70 °C
operating altitude: 3000 m without derating
mechanical robustness: Vibrations contactor open: 2 Gn, 5...300 Hz; Vibrations contactor closed: 5 Gn, 5...300 Hz; Shocks contactor open: 6 Gn for 1/2 sine wave (11 ms); Shocks contactor closed: 15 Gn for 1/2 sine wave (11 ms)
height: 206 mm
width: 261 mm
depth: 219 mm
net weight: 9.5 kg
Offer Sustainability
Sustainable offer status: Green Premium product
REACh Regulation: Free of Substances of Very High Concern above the threshold
EU RoHS Directive: Compliant
Mercury free: Yes
RoHS exemption information: Yes
China RoHS Regulation: Product out of China RoHS scope. Substance declaration for your information
Environmental Disclosure: ENVPEP1505009EN
Circularity Profile: ENVEOLI1505009EN
WEEE: The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
© 2018 Alplan Kft.