Skip to main content

Schneider-Electric
LC1BR33Q22

bar-mounted contactor - TeSys LC1-BR - 3 poles - AC-3 440V 1800 A - coil 380V AC
Barcode: 3389110103113
Tariff code:

This product is discontinued.

Please contact us for possible replacement product options.

Link to the manufacturers site: LC1BR33Q22 - bar-mounted contactor - TeSys LC1-BR - 3 poles - AC-3 440V 1800 A - coil 380V AC

Main

range of product: TeSys B

range: TeSys

product name: TeSys B

product or component type: Contactor

device short name: LC1BR

contactor application: Motor-heating-lighting

utilisation category: AC-1; AC-3

control circuit type: AC

coil type: Standard

poles description: 3P

pole contact composition: 3 NO

[Ie] rated operational current: 2750 A (at <40 °C) AC AC-1 for power circuit; 1800 A (at <55 °C) AC AC-3 for power circuit

motor power kW: 500 kW at 220...230 V AC 50/60 Hz (AC-3); 750 kW at 1000 V AC 50/60 Hz (AC-3); 900 kW at 380...400 V AC 50/60 Hz (AC-3); 900 kW at 415 V AC 50/60 Hz (AC-3); 900 kW at 440 V AC 50/60 Hz (AC-3); 900 kW at 500 V AC 50/60 Hz (AC-3); 900 kW at 660...690 V AC 50/60 Hz (AC-3); 250 kW at 400 V AC 50/60 Hz (AC-4)

auxiliary contact composition: 2 NO + 2 NC

[Uc] control circuit voltage: 380 V AC 50...400 Hz

Complementary

control circuit voltage limits: Drop-out: 0.4...0.5 Uc at 50...400 Hz; Operational: 0.85...1.1 Ucw at 50...400 Hz

[Ui] rated insulation voltage: 1000 V - for power circuit conforming to IEC 60158-1; 1000 V - for power circuit conforming to IEC 60947-4; 1500 V - for power circuit conforming to VDE 0110 group C

mounting mode: Fixed

mounting support: Bar support bracket; Notched mounting rails

connections - terminals: Power circuit: bolted connection

tightening torque: Power circuit: 35 N.m - on bars

[Ue] rated operational voltage: Power circuit: <= 1000 V AC 50/60 Hz

[Ith] conventional free air thermal current: 2750 A (at 40 °C) for power circuit

Irms rated making capacity: 18000 A at 1000 V AC for power circuit conforming to IEC 60158-1; 18000 A at 1000 V AC for power circuit conforming to IEC 60947-4

rated breaking capacity: 11000 A at 660...690 V for power circuit conforming to IEC 60158-1; 11000 A at 660...690 V for power circuit conforming to IEC 60947-4; 15000 A at 500 V for power circuit conforming to IEC 60158-1; 15000 A at 500 V for power circuit conforming to IEC 60947-4; 18000 A at 440 V for power circuit conforming to IEC 60158-1; 18000 A at 440 V for power circuit conforming to IEC 60947-4; 6000 A at 1000 V for power circuit conforming to IEC 60158-1; 6000 A at 1000 V for power circuit conforming to IEC 60947-4

associated fuse rating: 2000 A aM at <= 440 V for power circuit; 2400 A gI at <= 440 V for power circuit

average impedance: 0.09 mOhm - Ith 2750 A 50 Hz for power circuit

power dissipation per pole: 360 W AC-3 - Ith 2750 A; 680 W AC-1 - Ith 2750 A

inrush power in VA: 1300 VA

hold-in power consumption in VA: 31 VA 50/60 Hz

operating time: 100...150 ms closing; 50...100 ms opening

mechanical durability: 1200000 cycles

maximum operating rate: 120 cyc/h 55 °C

height: 495 mm

width: 915 mm

depth: 475 mm

net weight: 129 kg

compatibility code: LC1BR

Environment

standards: IEC 60947-4; BS 5424; VDE 0660; NF C 63-110; IEC 60158-1

product certifications: BV; CSA; RINA

protective treatment: TC; TH

ambient air temperature for operation: -5…55 °C

ambient air temperature for storage: -60…80 °C

operating altitude: 3000 m without derating

Offer Sustainability

REACh Regulation: Free of Substances of Very High Concern above the threshold

EU RoHS Directive: Compliant

Mercury free: Yes

RoHS exemption information: Yes

China RoHS Regulation: Product out of China RoHS scope. Substance declaration for your information

WEEE: The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins