RCCB with re-closer - RED - 2 poles - 25 A - class A - 30 mA
In stock: 1 pc(s)
Barcode: 3303430186878
Tariff code:

This product is discontinued.

This product is no longer manufactured, but we have it in stock. Please contact us for price and delivery information!

Link to the manufacturers site: 18687 - RCCB with re-closer - RED - 2 poles - 25 A - class A - 30 mA

Main

range of product: RED

range: Acti 9

product or component type: Residual current circuit breaker (RCCB)

device short name: REDs

protection type: Recloser

poles description: 2P

neutral position: Left

signal contacts composition: 1NO or 1NC or intermittent 1 Hz

[In] rated current: 25 A

earthing system: TN-S; TT

network type: AC

earth-leakage sensitivity: 30 mA

Complementary

device location in system: Outgoer

network frequency: 50 Hz

[Ue] rated operational voltage: 230 V AC 50 Hz phase to neutral

reset: Fault reset earth leakage

test function: Manual at > 100 V

earth-leakage protection time delay: Instantaneous

earth-leakage protection class: Type A

minimum leakage resistance: 16 kOhm at operating; 8 kOhm at non-operating

[Im] rated making and breaking capacity: Idm 630 A 230 V

rated conditional short-circuit current: Inc: 6 kA - associated with DPN, 40 A; Inc: 10 kA - associated with DPNN, 40 A; Inc: 10 kA - associated with iC60N, 25 A; Inc: 10 kA - associated with iC60H, 25 A; Inc: 10 kA - associated with iC60L, 25 A; Inc: 10 kA - associated with NG125, 25 A; Inc: 10 kA - associated with gG fuse, 25 A

[Ui] rated insulation voltage: 500 V

[Uimp] rated impulse withstand voltage: 4 kV

surge current: 250 A

control type: Toggle

local signalling: 2 LEDs; Residual current device : ON/OFF indication; Recloser : ON/OFF indication

operating mode: Reclosing time: < 90 s; Max nb of consecutive restart: 3; Min interval between 2 closings: 180 s; Stopping restart cycle if insulation fault present; Insulation fault presence monitoring

signalling circuit voltage: AC: 5...230 V; DC: 5...230 V

signalling output current: 0.6 mA min; 100 mA max, cos phi =1

mounting mode: Fixed

mounting support: 35 mm symmetrical DIN rail

9 mm pitches: 8

height: 115 mm

width: 71 mm

depth: 79.5 mm

net weight: 0.36 kg

mechanical durability: 1000 cycles open-close

connections - terminals: Guard tunnel terminal 35 mm² rigid; Guard tunnel terminal 35 mm² flexible; Guard tunnel terminal 35 mm² flexible with ferrule

auxiliary connection terminal: Tunnel type terminal in 2.5 mm² flexible; Tunnel type terminal in 2.5 mm² rigid; Tunnel type terminal in 2.5 mm² flexible with ferrule

wire stripping length: Power circuit: 12 mm; Signaling: 9 mm

tightening torque: Power circuit: 2 N.m; Signaling: 0.4 N.m

market segment: Small commercial

compatibility code: REDs

Environment

standards: EN 61008; IEC 61008

IP degree of protection: IP20

pollution degree: 2

electromagnetic compatibility: 8/20 µs wave immunity, 250 A

tropicalisation: 2

relative humidity: 95 % at 55 °C

ambient air temperature for operation: -5…40 °C

ambient air temperature for storage: -20…60 °C

Offer Sustainability

REACh Regulation: Free of Substances of Very High Concern above the threshold

REACh free of SVHC: Yes

EU RoHS Directive: Compliant

Toxic heavy metal free: Yes

Mercury free: Yes

RoHS exemption information: Yes

China RoHS Regulation:  Pro-active China RoHS declaration (out of China RoHS legal scope)

WEEE: The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins