Schneider-Electric
XESB2011
Tariff code: 8536508090
Link to the manufacturers site: XESB2011 - PENDANT STATION CONTACT 600VAC 10A XE
Main
Range of produc: Harmony XAC
Product or component type: Contact block
component name: XESB
Electrical circuit type: Control circuit
Contact block application: Single speed
Contact block type: Single
Type of operator: Spring return
Product compatibility: XACM; XACB; XAB91...
Mechanical interlocking: Without mechanical interlock
Mounting of block: Front mounting
contact operation: Snap action
Complementary
Connections - terminals: Screw clamp terminals, 1 x 2.5 mm² with or without cable end; Screw clamp terminals, 2 x 1.5 mm² with or without cable end
Mechanical durability: 1000000 cycles
Contact code designation: A300 AC-15, Ue = 240 V, Ie = 3 A conforming to IEC 60947-5-1 appendix A; Q300 DC-13, Ue = 250 V, Ie = 0.27 A conforming to IEC 60947-5-1 appendix A
[Ithe] conventional enclosed thermal current: 10 A
[Ui] rated insulation voltage: 500 V (pollution degree 3) conforming to IEC 60947-1
[Uimp] rated impulse withstand voltage: 6 kV conforming to IEC 60947-1
Maximum resistance across terminals: 25 MOhm
Operating force: 25 N; 15 N
Short-circuit protection: 10 A fuse protection by cartridge fuse type gG
Rated operational power in W: 140 W DC-13 for 1000000 cycles, operating rate <60 cyc/mn at 24 V, load factor = 0.5 (inductive load) conforming to IEC 60947-5-1 appendix C; 140 W DC-13 for 1000000 cycles, operating rate <60 cyc/mn at 48 V, load factor = 0.5 (inductive load) conforming to IEC 60947-5-1 appendix C; 95 W DC-13 for 1000000 cycles, operating rate <60 cyc/mn at 120 V, load factor = 0.5 (inductive load) conforming to IEC 60947-5-1 appendix C
Rated operational power in VA: 100 VA AC-15 for 1000000 cycles, operating rate <60 cyc/mn at 48 V 50/60 Hz, load factor = 0.5 (inductive load); 450 VA AC-15 for 1000000 cycles, operating rate <60 cyc/mn at 127 V 50/60 Hz, load factor = 0.5 (inductive load); 50 VA AC-15 for 1000000 cycles, operating rate <60 cyc/mn at 24 V 50/60 Hz, load factor = 0.5 (inductive load); 750 VA AC-15 for 1000000 cycles, operating rate <60 cyc/mn at 230 V 50/60 Hz, load factor = 0.5 (inductive load)
Terminals description ISO n°1: (3-4-1-2)OF
Terminal identifier: (13-14)NO; (11-12)NC
Environment
Standards: IEC 60947-5-1; CSA C22.2 No 14; IEC 60947-5-1
ambient air temperature for operation: -25…70 °C
Ambient air temperature for storage: -40…70 °C
Vibration resistance: 15 gn (f= 10…500 Hz) conforming to IEC 60068-2-6
Shock resistance: 100 gn conforming to IEC 60068-2-27
Electrical shock protection class: Class II conforming to IEC 61140
Packing Units
Unit Type of Package 1: PCE
Number of Units in Package 1: 1
Package 1 Height: 4.3 cm
Package 1 Width: 6.4 cm
Package 1 Length: 8.6 cm
Package 1 Weight: 30.0 g
Unit Type of Package 2: S02
Number of Units in Package 2: 100
Package 2 Height: 15.0 cm
Package 2 Width: 30.0 cm
Package 2 Length: 40.0 cm
Package 2 Weight: 3.206 kg
Offer Sustainability
REACh Regulation: Free of Substances of Very High Concern above the threshold
REACh free of SVHC: Yes
EU RoHS Directive: Pro-active compliance (Product out of EU RoHS legal scope)
Toxic heavy metal free: Yes
Mercury free: Yes
China RoHS Regulation: X
RoHS exemption information: Yes
WEEE: The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins