Skip to main content

Schneider-Electric
XESB2011

PENDANT STATION CONTACT 600VAC 10A XE
Net discounted price 14.37 EUR
Available when ordered (delivery time: 6 working day(s))
Barcode: 3389110607987
Tariff code: 8536508090

Link to the manufacturers site: XESB2011 - PENDANT STATION CONTACT 600VAC 10A XE

Main

Range of produc: Harmony XAC

Product or component type: Contact block

component name: XESB

Electrical circuit type: Control circuit

Contact block application: Single speed

Contact block type: Single

Type of operator: Spring return

Product compatibility: XACM; XACB; XAB91...

Mechanical interlocking: Without mechanical interlock

Mounting of block: Front mounting

contact operation: Snap action

Complementary

Connections - terminals: Screw clamp terminals, 1 x 2.5 mm² with or without cable end; Screw clamp terminals, 2 x 1.5 mm² with or without cable end

Mechanical durability: 1000000 cycles

Contact code designation: A300 AC-15, Ue = 240 V, Ie = 3 A conforming to IEC 60947-5-1 appendix A; Q300 DC-13, Ue = 250 V, Ie = 0.27 A conforming to IEC 60947-5-1 appendix A

[Ithe] conventional enclosed thermal current: 10 A

[Ui] rated insulation voltage: 500 V (pollution degree 3) conforming to IEC 60947-1

[Uimp] rated impulse withstand voltage: 6 kV conforming to IEC 60947-1

Maximum resistance across terminals: 25 MOhm

Operating force: 25 N; 15 N

Short-circuit protection: 10 A fuse protection by cartridge fuse type gG

Rated operational power in W: 140 W DC-13 for 1000000 cycles, operating rate <60 cyc/mn at 24 V, load factor = 0.5 (inductive load) conforming to IEC 60947-5-1 appendix C; 140 W DC-13 for 1000000 cycles, operating rate <60 cyc/mn at 48 V, load factor = 0.5 (inductive load) conforming to IEC 60947-5-1 appendix C; 95 W DC-13 for 1000000 cycles, operating rate <60 cyc/mn at 120 V, load factor = 0.5 (inductive load) conforming to IEC 60947-5-1 appendix C

Rated operational power in VA: 100 VA AC-15 for 1000000 cycles, operating rate <60 cyc/mn at 48 V 50/60 Hz, load factor = 0.5 (inductive load); 450 VA AC-15 for 1000000 cycles, operating rate <60 cyc/mn at 127 V 50/60 Hz, load factor = 0.5 (inductive load); 50 VA AC-15 for 1000000 cycles, operating rate <60 cyc/mn at 24 V 50/60 Hz, load factor = 0.5 (inductive load); 750 VA AC-15 for 1000000 cycles, operating rate <60 cyc/mn at 230 V 50/60 Hz, load factor = 0.5 (inductive load)

Terminals description ISO n°1: (3-4-1-2)OF

Terminal identifier: (13-14)NO; (11-12)NC

Environment

Standards: IEC 60947-5-1; CSA C22.2 No 14; IEC 60947-5-1

ambient air temperature for operation: -25…70 °C

Ambient air temperature for storage: -40…70 °C

Vibration resistance: 15 gn (f= 10…500 Hz) conforming to IEC 60068-2-6

Shock resistance: 100 gn conforming to IEC 60068-2-27

Electrical shock protection class: Class II conforming to IEC 61140

Packing Units

Unit Type of Package 1: PCE

Number of Units in Package 1: 1

Package 1 Height: 4.3 cm

Package 1 Width: 6.4 cm

Package 1 Length: 8.6 cm

Package 1 Weight: 30.0 g

Unit Type of Package 2: S02

Number of Units in Package 2: 100

Package 2 Height: 15.0 cm

Package 2 Width: 30.0 cm

Package 2 Length: 40.0 cm

Package 2 Weight: 3.206 kg

Offer Sustainability

REACh Regulation: Free of Substances of Very High Concern above the threshold

REACh free of SVHC: Yes

EU RoHS Directive: Pro-active compliance (Product out of EU RoHS legal scope)

Toxic heavy metal free: Yes

Mercury free: Yes

China RoHS Regulation: X

RoHS exemption information: Yes

WEEE: The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins

© 2018 Alplan Kft.