Schneider-Electric
ZBRRH
Tariff code: 8537109899
Link to the manufacturers site: ZBRRH - Configurable receiver for Harmony Hub
Main
Range of produc: Harmony
Product or component type: Wireless receiver
Device short name: ZBRRH
Product specific application: Interface to Harmony hub
function of module: Bi-stable
Reset time: 2 ms time delay
Transmission frequency: 2405 MHz
Level or class: 5M00G7W
Antenna type: Omnidirectional
Complementary
Output type: Transistor PNP
Output contacts: 4 PNP
Time delay range: 0.5 s (tolerance: - 15...15 %)
Maximum switching current: 0.2 mA DC
Minimum switching current: 10 mA at 5 V DC
[Us] rated supply voltage: 24 V DC - 15...20 %
Maximum voltage drop: <2 V DC at 2 A
Communication port protocol: Zigbee green power at 2.4 GHz conforming to IEEE 802.15.4
Maximum sensing distance: 100 m in free field; 25 m transmitter in a plastic box type XAL D and receiver in a metal enclosure; 40 m transmitter in box type XAL D, receiver in metal enclosure and use relay-antenna
Response time: < 30 ms after transmitter clicks
Channels utilisation: 1 Harmony Hub per receiver
Utilisation category: DC-13 conforming to EN/IEC 60947-5-1
Maximum power consumption in VA: 20 VA DC
Maximum power consumption in W: 20 W DC
Breaking capacity: 4.8 W (per output)
Short-circuit protection: 0.4 A fuse type fast blow
Operating position: Any position without derating
Electrical connection: 1 conductor cable 0.14…2.5 mm² - AWG 26...AWG 14 - solid - without cable end conforming to IEC 60947-1; 2 conductors cable 0.14…1.5 mm² - AWG 26...AWG 16 - solid - without cable end conforming to IEC 60947-1; 1 conductor cable 0.14…4 mm² - AWG 26...AWG 12 - flexible - with cable end conforming to IEC 60947-1; 2 conductors cable 0.14…1.5 mm² - AWG 26...AWG 16 - flexible - with cable end conforming to IEC 60947-1
Tightening torque: 0.5…1 N.m conforming to EN/IEC 60947-1
Housing material: Self-extinguishing plastic
Status LED: 1 LED green for power ON; 1 LED green and yellow for reception signal; 4 LEDs green for relay ON
Mounting support: 35 mm symmetrical DIN rail conforming to EN/IEC 60715; Mounting plate
Rated short-duration power frequency withstand voltage: 1 kV 50 Hz conforming to EN/IEC 60947-5-1
[Uimp] rated impulse withstand voltage: 0.8 kV
Surge withstand: 0.5 kV differential mode conforming to IEC 61000-4-5; 1 kV common mode conforming to IEC 61000-4-5
Max power consumption in W: 1 mW
Number of channels: 1
modulation technique: O-QPSK
Bandwidth: 5 MHz
Antenna gain: 0 dBi
Width: 36 mm
height: 108 mm
Depth: 75 mm
Net weight: 0.13 kg
Environment
Standards: EN/IEC 60947-5-1
Radio agreement: RSS; SRRC; ANATEL; ARIB T66; FCC; ICASA
product certifications: CCC; CSA; GOST; C-Tick; UL
Marking: CE
Ambient air temperature for storage: -40…70 °C
Relative humidity: 90 % at -20…55 °C, without condensation conforming to ETSI EN 300 440-1
Vibration resistance: +/- 7.5 mm (f= 5…14 Hz) conforming to IEC 60068-2-6; 2 gn (f= 8…150 Hz) conforming to IEC 60068-2-6
Shock resistance: 10 gn (duration = 16 ms) for 6000 shocks conforming to IEC 60068-2-27
IP degree of protection: IP20 (casing) conforming to IEC 60529; IP20 (terminals)
Pollution degree: 2 conforming to IEC 60664-1
Overvoltage category: III conforming to IEC 60664-1
Insulation resistance: > 500 MOhm at 500 V DC conforming to NF C 20-030
[Ui] rated insulation voltage: 60 V conforming to IEC 60664-1
Electromagnetic compatibility: Immunity for industrial environments conforming to EN/IEC 61000-6-2; Conducted and radiated emissions class B conforming to CISPR 22; Electrostatic discharge immunity test - test level: 8 kV (in free air (in insulating parts)) conforming to IEC 61000-4-2; Electrostatic discharge immunity test - test level: 6 kV (on contact (on metal parts)) conforming to IEC 61000-4-2; Susceptibility to electromagnetic fields - test level: 10 V/m (80...2000 MHz) conforming to IEC 61000-4-3; Susceptibility to electromagnetic fields - test level: 3 V/m (80...2700 MHz, distance = 20 m) conforming to IEC 61000-4-3; Electrical fast transient/burst immunity test - test level: 2 kV (power supply wires) conforming to IEC 61000-4-4; Conducted RF disturbances - test level: 10 V conforming to IEC 61000-4-6; Radiated emission conforming to ETSI EN 300 440-1; Conducted emission conforming to EN 300-489-1; Conducted emission conforming to ETSI EN 300 489-3; Radiated emission conforming to ETSI EN 300 440-2; Electrical fast transient/burst immunity test - test level: 1 kV (PNP output wires) conforming to IEC 61000-4-4; 1.2/50 µs shock waves immunity test - test level: 0.5 kV (differential mode) conforming to IEC 61000-4-5; 1.2/50 µs shock waves immunity test - test level: 1 kV (common mode) conforming to IEC 61000-4-5; Immunity to microbreaks and voltage drops - test level: 7 ms conforming to IEC 61000-4-11
Packing Units
Unit Type of Package 1: PCE
Number of Units in Package 1: 1
Package 1 Height: 9.200 cm
Package 1 Width: 10.800 cm
Package 1 Length: 10.200 cm
Package 1 Weight: 118.000 g
Unit Type of Package 2: S03
Number of Units in Package 2: 64
Package 2 Height: 30.000 cm
Package 2 Width: 30.000 cm
Package 2 Length: 40.000 cm
Package 2 Weight: 8.400 kg
Offer Sustainability
Sustainable offer status: Green Premium product
REACh Regulation: Reference contains Substances of Very High Concern above the threshold
EU RoHS Directive: Pro-active compliance (Product out of EU RoHS legal scope)
Mercury free: Yes
China RoHS Regulation: X
RoHS exemption information: Yes
Environmental Disclosure: ENVPEP101106EN
Circularity Profile: ENVEOLI1103010EN
WEEE: The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
© 2018 Alplan Kft.