Schneider-Electric
XPSUAB11CP
Tariff code: 8536419089
Link to the manufacturers site: XPSUAB11CP - Preventa biztonsági relé modul, Cat.1, biztonsági be/ki: 1/1CO, PNP, 24VAC/DC, csavaros, nem bővíthető
Main
Range of product: Harmony Safety Automation
product or component type: Safety module
safety module name: XPSUAB
safety module application: For electrical monitoring of two-hand control stations; For application with safety switchover contact; For emergency stop, guard and light curtain monitoring; Monitoring antivalent contacts
function of module: Emergency stop monitoring 1-channel wiring; Guard monitoring 1-channel wiring; Monitoring 1 PNP sensor; Monitoring two-hand control station type IIIA; Magnetic switch monitoring; Light curtain monitoring; RFID switch; Monitoring of electro-sensitive protection equipment (ESPE); Proximity sensor monitoring
Safety level: Can reach PL c/category 1 conforming to ISO 13849-1; Can reach SILCL 1 conforming to IEC 62061; Can reach SIL 1 conforming to IEC 61508
Safety reliability data: MTTFd >= 30 years conforming to ISO 13849-1; Dcavg < 60 % conforming to ISO 13849-1; PFHd = 1177E-09 1/h conforming to ISO 13849-1; HFT = 0 conforming to IEC 62061; PFHd = 1177E-09 1/h conforming to IEC 62061; SFF > 60% conforming to IEC 62061; HFT=0 conforming to IEC 61508-1; PFHd = 1177E-09 1/h conforming to IEC 61508-1; SFF > 60% conforming to IEC 61508-1; Type = B conforming to IEC 61508-1
electrical circuit type: NC pair; PNP pair; Antivalent pair; OSSD pair
Connections - terminals: Removable screw terminal block, 0.2...2.5 mm² solid or flexible; Removable screw terminal block, 0.25...2.5 mm² flexible with ferrule single conductor; Removable screw terminal block, 0.2...1.5 mm² solid or flexible twin conductor; Removable screw terminal block, 2 x 0.25...1 mm² flexible with ferrule without cable end, with bezel; Removable screw terminal block, 2 x 0.5...1.5 mm² flexible with ferrule with cable end, with bezel
[Us] rated supply voltage: 24 V AC - 15...10 %; 24 V DC - 20...20 %
Complementary
Synchronisation time between inputs: 0.5 s; 2.2 s
Type of start: Automatic/manual/monitored
Power consumption in W: 1.5 W 24 V DC
Power consumption in VA: 3.5 VA 24 V AC 50/60 Hz
Input protection type: Internal, electronic
Auxiliary contact composition: 1 C/O
Number of inputs: 1 safety input 24 V DC 5 mA
maximum line resistance: 500 Ohm
Input compatibility: Normally closed circuit conforming to ISO 14119; XC limit switch conforming to ISO 14119; Mechanical contact conforming to ISO 14119; Normally closed circuit conforming to ISO 13850; Antivalent pair conforming to ISO 14119; OSSD pair conforming to IEC 61496-1-2; Two-hand control conforming to EN 574/ISO 13851-III A; 3-wire proximity sensors PNP
[Ie] rated operational current: 5 A AC-1 for normally open relay contact; 3 A AC-15 for normally open relay contact; 5 A DC-1 for normally open relay contact; 3 A DC-13 for normally open relay contact; 3 A AC-1 for normally closed relay contact; 1 A AC-15 for normally closed relay contact; 2 A DC-1 for normally closed relay contact; 1 A DC-13 for normally closed relay contact
Number of outputs: 2 on/off configurable pulsed output
Input/output type: Semiconductor pulsed diagnostic output 24 V DC, 20 mA Z1, not safety-related
[Ith] conventional free air thermal current: 3 A
Associated fuse rating: 6 A gG for relay output conforming to IEC 60947-1
Minimum output current: 10 mA for relay output
Minimum output voltage: 15 V for relay output
Maximum response time on input open: 20 ms
[Ui] rated insulation voltage: 250 V (pollution degree 2) conforming to EN/IEC 60947-1
[Uimp] rated impulse withstand voltage: 4 kV overvoltage category II conforming to EN/IEC 60947-1
Local signalling: LED (green) for power ON; LED (red) for error; LED (yellow) for start; LED (yellow) for safety status; LED (yellow) for safety input S12; LED (yellow) for safety input S13
Mounting support: 35 mm symmetrical DIN rail
depth: 120 mm
Ambient air temperature for operation: -25…55 °C
height: 100 mm
width: 22.5 mm
net weight: 0.200 kg
Environment
Standards: IEC 60947-5-1; IEC 61508-1 functional safety standard; IEC 61508-2 functional safety standard; IEC 61508-3 functional safety standard; IEC 61508-4 functional safety standard; IEC 61508-5 functional safety standard; IEC 61508-6 functional safety standard; IEC 61508-7 functional safety standard; ISO 13849-1 functional safety standard; IEC 62061 functional safety standard
Product certifications: TÜV; cULus
IP degree of protection: IP20 (terminals) conforming to EN/IEC 60529; IP40 (housing) conforming to EN/IEC 60529; IP54 (mounting area) conforming to EN/IEC 60529
Relative humidity: 5…95 % non-condensing
Packing Units
Unit Type of Package 1: PCE
Number of Units in Package 1: 1
Package 1 Height: 6.5 cm
Package 1 Width: 15.5 cm
Package 1 Length: 13.5 cm
Package 1 Weight: 250.0 g
Unit Type of Package 2: S03
Number of Units in Package 2: 16
Package 2 Height: 30 cm
Package 2 Width: 30 cm
Package 2 Length: 40 cm
Package 2 Weight: 4.73 kg
Offer Sustainability
Sustainable offer status: Green Premium product
REACh Regulation: Reference contains Substances of Very High Concern above the threshold
EU RoHS Directive: Pro-active compliance (Product out of EU RoHS legal scope)
Mercury free: Yes
China RoHS Regulation: X
RoHS exemption information: Yes
Environmental Disclosure: ENVPEP1811003EN
Circularity Profile: ENVEOLI1811003EN
WEEE: The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
PVC free: Yes
© 2018 Alplan Kft.