Schneider-Electric
TM100C16RN
Tariff code: 8537109199
Link to the manufacturers site: TM100C16RN - Controller M100 - 9I/7O relay - 220VAC
Main
Range of produc: Easy Modicon M100
Product or component type: Logic controller
[Us] rated supply voltage: 100...240 V AC
Discrete I/O number: 16
Discrete input number: I2...I5: 4 fast input; I6...I8: 3 regular input; I0...I1: 2 high speed input
Discrete output number: 7 relay
Discrete input voltage: 24 V
discrete input voltage type: DC
Discrete input current: 7 mA for regular input; 7 mA for fast input; 9 mA for high speed input
Discrete output voltage: 24 V DC; 220 V AC
Discrete output current: 2 A
Discrete output type: Relay normally open
Power consumption in VA: 30…40 VA at 100...240 V AC (with max I/O)
Complementary
Supply voltage limits: 85…264 V
Voltage state 1 guaranteed: >= 15 V for input
Voltage state 0 guaranteed: <= 5 V for input
Network frequency: 50/60 Hz
Inrush current: 50 A
Input impedance: 3.3 kOhm for regular input; 3.3 kOhm for fast input; 2.81 kOhm for high speed input
Response time: 10 ms turn-on, Q0...Q6 terminal(s) for relay output; 10 ms turn-off, Q0...Q6 terminal(s) for relay output; 35 µs turn-on, I2...I5 terminal(s) for fast input; 100 µs turn-off, I2...I5 terminal(s) for fast input; 5 µs turn-on, I0...I1 terminal(s) for high speed input; 5 µs turn-off, I0...I1 terminal(s) for high speed input; 35 µs turn-on, I6...I8 terminal(s) for regular input; 100 µs turn-off, I6...I8 terminal(s) for regular input
Configurable filtering time: 0 ms for input; 3 ms for input; 12 ms for input
Output voltage limits: 30 V DC; 250 V AC
Maximum current per output common: 4 A at COM 0; 4 A at COM 1
Electrical durability: 100000 cycles AC-12, 240 V, 480 VA, resistive; 100000 cycles DC-12, 24 V, 48 W, resistive
Switching frequency: 0.1 Hz with maximum load; 5 Hz without maximum load
Mechanical durability: 20000000 cycles for relay output
Minimum load: 10 mA at 5 V DC for relay output
Memory capacity: 1024 kB internal flash with 10000 instructions for backup of programs
Data storage equipment: 32 GB micro SD card (optional)
Execution time for 1 KInstruction: 0.3 ms for event and periodic task
Execution time per instruction: 0.2 µs Boolean
Exct time for event task: 60 µs response time
Regulation loop: Adjustable PID regulator up to 14 simultaneous loops
Control signal type: Quadrature (x1, x2, x4) at 60 kHz for fast input (HSC mode); Pulse/direction at 60 kHz for fast input (HSC mode); Single phase at 60 kHz for fast input (HSC mode); CW/CCW at 60 kHz for fast input (HSC mode)
Counting input number: 2 fast input (HSC mode) at 60 kHz 32 bits
Integrated connection type: USB port with mini B USB 2.0 connector; Non isolated serial link serial 1 with terminal block connector and RS485 interface ; Non isolated serial link serial 2 with terminal block connector and RS232/RS485 interface
Transmission rate: 1.2...115.2 kbit/s (115.2 kbit/s by default) for bus length of 15 m for RS485; 1.2...115.2 kbit/s (115.2 kbit/s by default) for bus length of 3 m for RS232; 12 Mbit/s for USB
Communication port protocol: USB port: USB - SoMachine-Network; Non isolated serial link: Modbus master/slave - RTU/ASCII or SoMachine-Network
Local signalling: 1 LED (green) for PWR; 1 LED (green) for RUN; 1 LED (red) for module error (ERR); 1 LED (green) for SD card access (SD); 1 LED (green) for SL1; 1 LED per channel (green) for I/O state
Electrical connection: removable screw terminal blockfor inputs; removable screw terminal blockfor outputs; removable screw terminal block, 4 terminal(s) for connecting the serial link1; Mini B USB 2.0 connectorfor a programming terminal; removable screw terminal block, 3 terminal(s) for connecting the 100-240 V AC power supply
Maximum cable distance between devices: Shielded cable: <10 m for fast input; Shielded cable: <10 m for high speed input; Unshielded cable: <150 m for output; Unshielded cable: <50 m for regular input
Insulation: Between input and internal logic at 560 V AC; Between fast input and internal logic at 560 V AC; Between input groups at 560 V AC; Non-insulated between inputs; Between output and internal logic at 1780 V AC; Between output groups at 1780 V AC; Between supply and internal logic at 1780 V AC
Sensor power supply: 24 V DC
Mounting support: Top hat type TH35-15 rail conforming to IEC 60715; Top hat type TH35-7.5 plate or panel with fixing kit conforming to IEC 60715
height: 90 mm
Depth: 70 mm
Width: 110 mm
Net weight: 0.31 kg
Environment
IP degree of protection: IP20 with protective cover in place
product certifications: CE
Standards: EN/IEC 61010-2-201; EN/IEC 61131-2
Electromagnetic compatibility: Electrostatic discharge immunity test - test level: 8 kV (air discharge) conforming to EN/IEC 61000-4-2; Electrostatic discharge immunity test - test level: 6 kV (contact discharge) conforming to EN/IEC 61000-4-2; Susceptibility to electromagnetic fields - test level: 10 V/m (80 MHz...3 GHz) conforming to EN/IEC 61000-4-3; Conducted emission - test level: 79 dBμV/m QP/66 dBμV/m AV (power lines (AC)) conforming to EN/IEC 55011; Conducted emission - test level: 73 dBμV/m QP/60 dBμV/m AV (power lines (AC)) conforming to EN/IEC 55011; Radiated emission - test level: 40 dBμV/m QP class A (10 m) conforming to EN/IEC 55011; Radiated emission - test level: 47 dBμV/m QP class A (10 m) conforming to EN/IEC 55011; Magnetic field at power frequency - test level: 30 A/m (I/O) conforming to EN/IEC 61000-4-8; Electrical fast transient/burst immunity test - test level: 2 kV (power lines) conforming to EN/IEC 61000-4-4; Electrical fast transient/burst immunity test - test level: 2 kV (relay output) conforming to EN/IEC 61000-4-4; Electrical fast transient/burst immunity test - test level: 1 kV (I/O) conforming to EN/IEC 61000-4-4; Electrical fast transient/burst immunity test - test level: 1 kV (serial link) conforming to EN/IEC 61000-4-4; 1.2/50 µs shock waves immunity test - test level: 1 kV (power lines (DC)) conforming to EN/IEC 61000-4-5; 1.2/50 µs shock waves immunity test - test level: 2 kV (power lines (AC)) conforming to EN/IEC 61000-4-5; 1.2/50 µs shock waves immunity test - test level: 2 kV (relay output) conforming to EN/IEC 61000-4-5; 1.2/50 µs shock waves immunity test - test level: 1 kV (I/O) conforming to EN/IEC 61000-4-5; 1.2/50 µs shock waves immunity test - test level: 1 kV (shielded cable) conforming to EN/IEC 61000-4-5; 1.2/50 µs shock waves immunity test - test level: 0.5 kV class A (power lines (DC)) conforming to EN/IEC 61000-4-5; 1.2/50 µs shock waves immunity test - test level: 1 kV class A (power lines (AC)) conforming to EN/IEC 61000-4-5; 1.2/50 µs shock waves immunity test - test level: 1 kV (relay output) conforming to EN/IEC 61000-4-5; Conducted RF disturbances - test level: 10 V (0.15...80 MHz) conforming to EN/IEC 61000-4-6
Shock resistance: 15 gn for 11 ms; 30 gn for 6 ms
Immunity to microbreaks: 10 ms
Vibration resistance: 3.5 mm at 5…8.4 Hz on symmetrical rail; 1 gn at 8.4…150 Hz on symmetrical rail; 3.5 mm at 5…8.4 Hz on panel mounting; 3 gn at 8.4…150 Hz on panel mounting
Relative humidity: 10…95 %, without condensation (in operation); 10…95 %, without condensation (in storage)
Ambient air temperature for operation: 0…55 °C (horizontal installation)
Ambient air temperature for storage: -25…70 °C
Pollution degree: <= 2
Operating altitude: 0...2000 m
Storage altitude: 0…3000 m
Packing Units
Unit Type of Package 1: PCE
Number of Units in Package 1: 1
Package 1 Height: 9.493 cm
Package 1 Width: 12.157 cm
Package 1 Length: 13.668 cm
Package 1 Weight: 450 g
Unit Type of Package 2: S03
Number of Units in Package 2: 18
Package 2 Height: 30 cm
Package 2 Width: 30 cm
Package 2 Length: 40 cm
Package 2 Weight: 8600 g
Unit Type of Package 3: P12
Number of Units in Package 3: 432
Package 3 Height: 95 cm
Package 3 Width: 80 cm
Package 3 Length: 120 cm
Package 3 Weight: 215400 g
Offer Sustainability
Sustainable offer status: Green Premium product
REACh Regulation: Reference contains Substances of Very High Concern above the threshold
EU RoHS Directive: Pro-active compliance (Product out of EU RoHS legal scope)
Mercury free: Yes
China RoHS Regulation: X
RoHS exemption information: Yes
Environmental Disclosure: ENVPEP1408013EN
Circularity Profile: ENVEOLI1408013EN
WEEE: The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins