Schneider-Electric
LC1E40B7
Tariff code:
This product is discontinued.
Please contact us for possible replacement product options.
Link to the manufacturers site: LC1E40B7 - EasyPact TVS contactor 3P(3 NO) - AC-3 - <= 440 V 40A - 24 V AC coil
Main
range: EasyPact
product name: EasyPact TVS
product or component type: Contactor
device short name: LC1E
contactor application: Resistive load; Motor control
utilisation category: AC-1; AC-3
poles description: 3P
pole contact composition: 3 NO
[Ue] rated operational voltage: Power circuit: <= 690 V AC 50/60 Hz
[Ie] rated operational current: 40 A (at <55 °C) at <= 440 V AC AC-3 for power circuit; 60 A (at <60 °C) at <= 440 V AC AC-1 for power circuit
motor power kW: 18.5 kW at 380...400 V; 11 kW at 220...230 V AC 50/60 Hz; 22 kW at 415 V; 22 kW at 440 V; 22 kW at 500 V; 30 kW at 660...690 V
control circuit type: AC at 50/60 Hz
[Uc] control circuit voltage: 24 V AC 50/60 Hz
height: 127 mm
width: 75 mm
depth: 114 mm
net weight: 0.98 kg
colour: Grey (RAL 7011)
Complementary
auxiliary contact composition: 1 NO + 1 NC
[Uimp] rated impulse withstand voltage: 6 kV coil not connected to the power circuit conforming to IEC 60947
[Ui] rated insulation voltage: 690 V conforming to IEC 60947-4-1
overvoltage category: III
Irms rated making capacity: 400 A at 440 V AC for power circuit conforming to IEC 60947-4-1
rated breaking capacity: 320 A at 440 V for power circuit conforming to IEC 60947
[Icw] rated short-time withstand current: 320 A 40 °C - 10 s for power circuit; 165 A 40 °C - 60 s for power circuit; 72 A 40 °C - 600 s for power circuit
associated fuse rating: 10 A gG at <= 690 V coordination type 1 for control circuit conforming to IEC 60947-5-1; 80 A gG at <= 690 V coordination type 1 for power circuit
average impedance: 1.5 mOhm - Ith 60 A 50 Hz for power circuit
power dissipation per pole: 2.4 W AC-3; 5.4 W AC-1
control circuit voltage limits: Operational: 0.85...1.1 Uc at 50/60 Hz (at <55 °C); Drop-out: 0.3...0.6 Uc at 50/60 Hz (at <55 °C)
operating time: 20...26 ms on closing; 8...12 ms on opening
mechanical durability: 5000000 cycles
maximum operating rate: 1200 cyc/h 55 °C
inrush power in VA: 160 VA 50 Hz cos phi 0.75 (at 20 °C); 140 VA 60 Hz cos phi 0.75 (at 20 °C)
hold-in power consumption in VA: 15 VA 50 Hz cos phi 0.3 (at 20 °C); 13 VA 60 Hz cos phi 0.3 (at 20 °C)
heat dissipation: 6…10 W for control circuit
minimum switching current: 5 mA for control circuit
minimum switching voltage: 17 V for control circuit
non-overlap time: 1.5 ms on energisation guaranteed between NC and NO contact; 1.5 ms on de-energisation guaranteed between NC and NO contact
insulation resistance: > 10 MOhm for control circuit
electrical durability: 350000 cycles AC-1; 900000 cycles AC-3
mounting support: Plate; DIN rail
connections - terminals: Control circuit: screw clamp terminals 1 1…4 mm² - cable stiffness: flexible without cable end; Control circuit: screw clamp terminals 2 1…4 mm² - cable stiffness: flexible without cable end; Control circuit: screw clamp terminals 1 1…4 mm² - cable stiffness: flexible with cable end; Control circuit: screw clamp terminals 2 1…2.5 mm² - cable stiffness: flexible with cable end; Control circuit: screw clamp terminals 1 1…4 mm² - cable stiffness: solid without cable end; Control circuit: screw clamp terminals 2 1…4 mm² - cable stiffness: solid without cable end; Power circuit: screw clamp terminals 1 2.5…25 mm² - cable stiffness: flexible with cable end; Power circuit: screw clamp terminals 2 2.5…10 mm² - cable stiffness: flexible with cable end; Power circuit: screw clamp terminals 1 2.5…25 mm² - cable stiffness: solid without cable end; Power circuit: screw clamp terminals 2 2.5…16 mm² - cable stiffness: solid without cable end
tightening torque: Control circuit: 1.2 N.m; Power circuit: 5 N.m
Environment
standards: IEC 60947-1; IEC 60947-5-1; IEC 60947-4-1
product certifications: EAC; CE
IP degree of protection: IP2x conforming to IEC 60529
protective treatment: TH (pollution degree 3) conforming to IEC 60068-2-30 test Db
pollution degree: 3
ambient air temperature for operation: -5…55 °C
ambient air temperature for storage: -60…80 °C
permissible ambient air temperature around the device: -20…70 °C at Uc
operating altitude: 3000 m without derating
fire resistance: 850 °C conforming to IEC 60695-2-1
mechanical robustness: Vibrations contactor open: 1.5 Gn, 5...300 Hz; Vibrations contactor closed: 3 Gn, 5...300 Hz; Shocks contactor open: 6 Gn for 11 ms; Shocks contactor closed: 7 Gn for 11 ms
Offer Sustainability
Sustainable offer status: Green Premium product
REACh Regulation: Free of Substances of Very High Concern above the threshold
REACh free of SVHC: Yes
EU RoHS Directive: Compliant
Toxic heavy metal free: Yes
Mercury free: Yes
RoHS exemption information: Yes
China RoHS Regulation: X
Environmental Disclosure: ENVPEP1403016EN
WEEE: The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
© 2018 Alplan Kft.