Skip to main content

Schneider-Electric
ATV12P037F1

variable speed drive ATV12 - 0.37kW - 0.55hp - 100..120V - 1ph - on base plate
Barcode: 3606480071041
Tariff code: 8504409590

This product is discontinued.

Please contact us for possible replacement product options.

Link to the manufacturers site: ATV12P037F1 - variable speed drive ATV12 - 0.37kW - 0.55hp - 100..120V - 1ph - on base plate

Main

Range of produc: Altivar 12

Product or component type: Variable speed drive

Product specific application: Simple machine

Design of frequency changer: U converter

Mounting mode: Cabinet mount

communication port protocol: Modbus

Supply frequency: 50/60 Hz +/- 5 %

[Us] rated supply voltage: 100...120 V - 15...10 %

[Us] rated supply voltage: 100...120 V

Relative symmetric mains voltage tolerance: 10 %

Nominal output current: 2.4 A

Number of input phases: 3

Number of output phases: 3

Motor power hp: 0.55 hp

Motor power kW: 0.37 kW

EMC filter: Without EMC filter

IP degree of protection: IP20

Complementary

Discrete input number: 4

Discrete output number: 2

analogue input number: 1

analogue output number: 1

Relay output number: 1

Number of inputs, bidirectional, not potential-free: 0

Number of inputs, potential-free: 0

Computer port: True

Optical interface present: False

Physical interface: 2-wire RS 485

Connector type: 1 RJ45

Continuous output current: 2.4 A at 4 kHz

Method of access: Server Modbus serial

Speed drive output frequency: 0.5…400 Hz

Speed range: 1…20

Sampling duration: 20 ms, tolerance +/- 1 ms for logic input; 10 ms for analogue input

Linearity error: +/- 0.3 % of maximum value for analogue input

Frequency resolution: Analog input: converter A/D, 10 bits; Display unit: 0.1 Hz

Time constant: 20 ms +/- 1 ms for reference change

Transmission rate: 9.6 kbit/s; 19.2 kbit/s; 38.4 kbit/s

Transmission frame: RTU

Number of addresses: 1…247

Data format: 8 bits, configurable odd, even or no parity

Communication service: Read holding registers (03) 29 words; Write single register (06) 29 words; Write multiple registers (16) 27 words; Read/write multiple registers (23) 4/4 words; Read device identification (43)

Type of polarization: No impedance

Number of HW interfaces parallel: 0

Number of HW interfaces industrial Ethernet: 0

Number of HW interfaces PROFINET: 0

Number of HW interfaces serial RS232: 0

Number of HW interfaces serial RS422: 0

Number of HW interfaces serial RS485: 1

Number of HW interfaces serial TTY: 0

Number of HW interfaces USB: 0

Number of HW interfaces other: 0

Supporting protocol for AS-Interface Safety at Work: False

Supporting protocol for ASI: False

Supporting protocol for SUCONET: False

Supporting protocol for BACnet: False

Supporting protocol for CAN: False

Supporting protocol for Data-Highway: False

Supporting protocol for DeviceNet: False

Supporting protocol for DeviceNet Safety: False

Supporting protocol for EtherNet/IP: False

Supporting protocol for Foundation Fieldbus: False

Supporting protocol for INTERBUS: False

Supporting protocol for INTERBUS-Safety: False

Supporting protocol for KNX: False

Supporting protocol for LON: False

Supporting protocol for MODBUS: True

Supporting protocol for other bus systems: False

Supporting protocol for PROFIBUS: False

Supporting protocol for PROFINET CBA: False

Supporting protocol for PROFINET IO: False

Supporting protocol for PROFIsafe: False

Supporting protocol for SafetyBUS P: False

Supporting protocol for SERCOS: False

Supporting protocol for TCP/IP: False

4 quadrant operation possible: False

Asynchronous motor control profile: Quadratic voltage/frequency ratio; Voltage/frequency ratio (V/f); Sensorless flux vector control

maximum output frequency: 4 kHz

Transient overtorque: 150…170 % of nominal motor torque depending on drive rating and type of motor

Acceleration and deceleration ramps: S; Linear from 0 to 999.9 s; U

Motor slip compensation: Adjustable; Preset in factory

Switching frequency: 2...16 kHz adjustable; 4...16 kHz with derating factor

Nominal switching frequency: 4 kHz

Braking to standstill: By DC injection

Brake chopper integrated: False

Maximum associated fuse rating: 12.5 A

Line current: 11.4 A at 100 V (heavy duty); 9.3 A at 120 V (heavy duty)

Maximum input current: 9.3 A

Maximum output voltage: 240 V

Nominal output power: 370.0 W

Apparent power: 1.1 kVA at 240 V (heavy duty)

Maximum transient current: 3.6 A during 60 s (heavy duty); 4.0 A during 2 s (heavy duty)

Capacity of DC link: 600.0 µF

Network frequency: 50...60 Hz

Relative symmetric network frequency tolerance: 5 %

Prospective line Isc: 1 kA

1 phase low current possible: False

Base load current at high overload: 2.4 A

Application in domestic and commercial area permitted: False

Application in industrial area permitted: True

EMC limit value (complied): False

Power loss per device current dependent: 29.0 W

Power loss static current independent: 8.0 W

Power dissipation in W: Natural: 29.0 W

Housing material: Plastic

With safety function Safely Limited Speed (SLS): False

With safety function Safe brake management (SBC/SBT): False

With safety function Safe Operating Stop (SOS): False

With safety function Safe Position (SP): False

With safety function Safe programmable logic: False

With safety function Safe Speed Monitor (SSM): False

With safety function Safe Stop 1 (SS1): False

With sft fct Safe Stop 2 (SS2): False

With safety function Safe torque off (STO): False

With safety function Safely Limited Position (SLP): False

With safety function Safe Direction (SDI): False

Protection type: Line supply overvoltage; Line supply undervoltage; Overcurrent between output phases and earth; Overheating protection; Short-circuit between motor phases; Against input phase loss in three-phase; Thermal motor protection via the drive by continuous calculation of I²t

Operating element present: True

Tightening torque: 0.8 N.m

insulation: Electrical between power and control

Quantity per set: Set of 1

Width: 72 mm

height: 143 mm

Depth: 102.2 mm

Net weight: 0.7 kg

Environment

Operating altitude: > 1000...2000 m with current derating 1 % per 100 m; <= 1000 m without derating

Operating position: Vertical +/- 10 degree

product certifications: NOM; CSA; C-Tick; UL; GOST; RCM; KC

Marking: CE

Standards: UL 508C; UL 618000-5-1; IEC 61800-5-1; IEC 61800-3

Assembly style: On base plate

Electromagnetic compatibility: Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4; Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2; Immunity to conducted disturbances level 3 conforming to IEC 61000-4-6; Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3; Surge immunity test level 3 conforming to IEC 61000-4-5; Voltage dips and interruptions immunity test conforming to IEC 61000-4-11

Environmental class (during operation): Class 3C3 according to IEC 60721-3-3; Class 3S2 according to IEC 60721-3-3

Environmental class (during storage): Class 1C3 according to IEC 60721-3-1; Class 1S2 according to IEC 60721-3-1

Environmental class (during transport): Class 2C3 according to IEC 60721-3-2; Class 2S1 according to IEC 60721-3-2

Maximum acceleration under shock impact (during operation): 150 m/s² at 11 ms

Maximum acceleration under shock load (during storage): 150 m/s² at 11 ms

Maximum acceleration under shock load (during transport): 150 m/s² at 11 ms

Maximum acceleration under vibratory load (during storage): 10 m/s² at 13...200 Hz

Maximum acceleration under vibratory load (during transport): 10 m/s² at 13...200 Hz

Maximum acceleration under vibrational stress (during operation): 10 m/s² at 13...200 Hz

Maximum deflection under vibratory load (during storage): 1.5 mm at 2...13 Hz

Maximum deflection under vibratory load (during transport): 1.5 mm at 2...13 Hz

ambient air temperature for operation: -10…60 °C

Maximum deflection under vibratory load (during operation): 1.5 mm at 2...13 Hz

Overvoltage category: Class III

Regulation loop: Adjustable PID regulator

Electromagnetic emission: Radiated emissions environment 1 category C2 conforming to IEC 61800-3 2...16 kHz shielded motor cable; Conducted emissions with additional EMC filter environment 1 category C1 conforming to IEC 61800-3 4...12 kHz shielded motor cable <5 m; Conducted emissions with additional EMC filter environment 1 category C2 conforming to IEC 61800-3 4...12 kHz shielded motor cable <20 m; Conducted emissions with additional EMC filter environment 2 category C3 conforming to IEC 61800-3 4...12 kHz shielded motor cable <20 m

Vibration resistance: 1 gn (f = 13…200 Hz) conforming to IEC 60068-2-6; 1.5 mm peak to peak (f = 3…13 Hz) - drive unmounted on symmetrical DIN rail - conforming to IEC 60068-2-6

Shock resistance: 15 gn conforming to IEC 60068-2-27 for 11 ms

Relative humidity: 5…95 % without condensation conforming to IEC 60068-2-3; 5…95 % without dripping water conforming to IEC 60068-2-3

Noise level: 0 dB

Pollution degree: 2

Ambient air transport temperature: -25…70 °C

Ambient air temperature for operation: -10…40 °C without derating; 40…60 °C with current derating 2.2 % per °C

Ambient air temperature for storage: -25…70 °C

Packing Units

Unit Type of Package 1: PCE

Number of Units in Package 1: 1

Package 1 Height: 11.6 cm

Package 1 Width: 18.8 cm

Package 1 Length: 19.7 cm

Package 1 Weight: 920 g

Unit Type of Package 2: P06

Number of Units in Package 2: 45

Package 2 Height: 75 cm

Package 2 Width: 60 cm

Package 2 Length: 80 cm

Package 2 Weight: 54.4 kg

Offer Sustainability

REACh Regulation: Reference contains Substances of Very High Concern above the threshold

EU RoHS Directive: Pro-active compliance (Product out of EU RoHS legal scope)

Mercury free: Yes

China RoHS Regulation: X

RoHS exemption information: Yes

WEEE: The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins

© 2018 Alplan Kft.