Skip to main content

Schneider-Electric
ZB4BW0G52

orange light block with body/fixing collar with integral LED 110...120V 1NC
Barcode: 3389110893410
Tariff code:

This product is discontinued.

Please contact us for possible replacement product options.

Link to the manufacturers site: ZB4BW0G52 - orange light block with body/fixing collar with integral LED 110...120V 1NC

Main

range of product: Harmony XB4

product or component type: Complete body/contact assembly and light block

device short name: ZB4

fixing collar material: Zamak

sale per indivisible quantity: 1

head type: Standard

contacts type and composition: 1 NC

contact operation: Slow-break

connections - terminals: Screw clamp terminals, <= 2 x 1.5 mm² with cable end conforming to EN 60947-1; Screw clamp terminals, >= 1 x 0.22 mm² without cable end conforming to EN 60947-1

light source: Protected LED

bulb base: Integral LED

light block supply: Direct

light source colour: Orange

[Us] rated supply voltage: 110...120 V AC at 50/60 Hz

[Us] rated supply voltage: 110...120 V

Complementary

CAD overall width: 30 mm

CAD overall height: 47 mm

terminals description ISO n°1: (11-12)NC

net weight: 0.064 kg

contacts usage: Standard

positive opening: With conforming to EN/IEC 60947-5-1 appendix K

operating travel: 1.5 mm (NC changing electrical state); 4.3 mm (total travel)

operating force: 2 N NC changing electrical state

mechanical durability: 5000000 cycles

tightening torque: 0.8…1.2 N.m conforming to EN 60947-1

shape of screw head: Cross compatible with Philips no 1 screwdriver; Cross compatible with pozidriv No 1 screwdriver; Slotted compatible with flat Ø 4 mm screwdriver; Slotted compatible with flat Ø 5.5 mm screwdriver

contacts material: Silver alloy (Ag/Ni)

short-circuit protection: 10 A cartridge fuse type gG conforming to EN/IEC 60947-5-1

[Ith] conventional free air thermal current: 10 A conforming to EN/IEC 60947-5-1

[Ui] rated insulation voltage: 600 V (pollution degree 3) conforming to EN 60947-1

[Uimp] rated impulse withstand voltage: 6 kV conforming to EN 60947-1

[Ie] rated operational current: 3 A at 240 V, AC-15, A600 conforming to EN/IEC 60947-5-1; 6 A at 120 V, AC-15, A600 conforming to EN/IEC 60947-5-1; 0.1 A at 600 V, DC-13, Q600 conforming to EN/IEC 60947-5-1; 0.27 A at 250 V, DC-13, Q600 conforming to EN/IEC 60947-5-1; 0.55 A at 125 V, DC-13, Q600 conforming to EN/IEC 60947-5-1; 1.2 A at 600 V, AC-15, A600 conforming to EN/IEC 60947-5-1

electrical durability: 1000000 cycles, AC-15, 2 A at 230 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to EN/IEC 60947-5-1 appendix C; 1000000 cycles, AC-15, 3 A at 120 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to EN/IEC 60947-5-1 appendix C; 1000000 cycles, AC-15, 4 A at 24 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to EN/IEC 60947-5-1 appendix C; 1000000 cycles, DC-13, 0.2 A at 110 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to EN/IEC 60947-5-1 appendix C; 1000000 cycles, DC-13, 0.5 A at 24 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to EN/IEC 60947-5-1 appendix C

electrical reliability: Λ < 10exp(-6) at 5 V and 1 mA in clean environment conforming to EN/IEC 60947-5-4; Λ < 10exp(-8) at 17 V and 5 mA in clean environment conforming to EN/IEC 60947-5-4

signalling type: Steady

current consumption: 14 mA

service life: 100000 h at rated voltage and 25 °C

surge withstand: 1 kV conforming to IEC 61000-4-5

device presentation: Basic sub-assemblies

customizable: No

customizable: 0

compatibility code: ZB4

Environment

protective treatment: TH

ambient air temperature for storage: -40…70 °C

ambient air temperature for operation: -40…70 °C

electrical shock protection class: Class I conforming to IEC 60536

standards: UL 508; EN/IEC 60947-5-5; EN/IEC 60947-5-1; CSA C22.2 No 14; JIS C8201-5-1; EN/IEC 60947-1; EN/IEC 60947-5-4; JIS C8201-1

product certifications: BV; GL; CSA; UL listed; DNV; LROS (Lloyds register of shipping)

vibration resistance: 5 gn (f= 2…500 Hz) conforming to IEC 60068-2-6

shock resistance: 30 gn (duration = 18 ms) for half sine wave acceleration conforming to IEC 60068-2-27; 50 gn (duration = 11 ms) for half sine wave acceleration conforming to IEC 60068-2-27

resistance to fast transients: 2 kV conforming to IEC 61000-4-4

resistance to electromagnetic fields: 10 V/m conforming to IEC 61000-4-3

resistance to electrostatic discharge: 6 kV on contact (on metal parts) conforming to IEC 61000-2-6; 8 kV in free air (in insulating parts) conforming to IEC 61000-2-6

electromagnetic emission: Class B conforming to IEC 55011

Offer Sustainability

Sustainable offer status: Green Premium product

REACh Regulation: Free of Substances of Very High Concern above the threshold

REACh free of SVHC: Yes

EU RoHS Directive: Pro-active compliance (Product out of EU RoHS legal scope)

Mercury free: Yes

RoHS exemption information: Yes

China RoHS Regulation: X

Environmental Disclosure: ENVPEP1808008EN

Circularity Profile: ENVEOLI1808008EN

WEEE: The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins

© 2018 Alplan Kft.