Schneider-Electric
XY2CE2A450EX
Tariff code: 8536508090
Link to the manufacturers site: XY2CE2A450EX - e-stop rope pull switch XY2CE - LH side -1NC+1NO - key-release pushbutton
Main
Range of produc: Telemecanique Emergency stop rope pull switches XY2C
Product or component type: Latching emergency stop trip wire switch
Device short name: XY2CE
local signalling: Without pilot light
Reset: By key-release push-button
Contacts type and composition: 1 NC + 1 NO
Trigger cable anchor point: LH side
Complementary
Number of cables: 1
Trigger cable maximum length: 70 m
Housing colour: Red RAL 3000
Key number: 421
Auxiliary contacts operation: Slow-break
Connections - terminals: Screw clamp terminal, 1 x 0.5...2 x 1.5 mm²
Tightening torque: 0.8…1.2 N.m
Cable entry number: 1 plain hole for ISO M20 cable gland; 2 plain hole with blanking plug for
Marking: II2 D-Ex tb IIIC T85°C Db IP65
Safety level: Can reach PL = e with the appropriate monitoring system and correctly wired conforming to EN/ISO 13849-1; Can reach category 4 with the appropriate monitoring system and correctly wired conforming to EN/ISO 13849-1; Can reach SIL 3 conforming to EN/IEC 61508
Safety reliability data: B10d = 300000 value given for a life time of 20 years limited by mechanical or contact wear
Mechanical durability: 60000 cycles
Distance between cable supports: 10 m
[Ie] rated operational current: 3 A at 240 V, AC-15, A300 conforming to EN/IEC 60947-5-1 appendix A; 0.27 A at 250 V, DC-13, Q300 conforming to EN/IEC 60947-5-1 appendix A
[Ithe] conventional enclosed thermal current: 10 A
[Ui] rated insulation voltage: 400 V (pollution degree 3) conforming to EN/IEC 60947-1; 300 V conforming to UL 508; 300 V conforming to CSA C22.2 No 14
[Uimp] rated impulse withstand voltage: 4 kV
Positive opening: With conforming to EN/IEC 60947-5-1 section 3
Maximum resistance across terminals: 25 MOhm conforming to EN/IEC 60255-7 category 3; 25 MOhm conforming to NF C 93-050 method A
Short-circuit protection: 10 A cartridge fuse type gG conforming to EN/IEC 60269
Width: 195 mm
Depth: 105 mm
height: 142 mm
Compatibility code: XY2CE
Environment
Standards: EN/IEC 60079-0; EN/IEC 60079-31
Directives: 2014/34/EU - ATEX directive
Dust zone: Zone 21 - 22
product certifications: INERIS 04ATEX0015; IEC-Ex INE 16.0001X
Protective treatment: TC
ambient air temperature for operation: -20…60 °C
Ambient air temperature for storage: -40…70 °C
Vibration resistance: 10 gn (f= 10…300 Hz) conforming to EN/IEC 60068-2-6
Shock resistance: 50 gn 11 ms conforming to EN/IEC 60068-2-27
Electrical shock protection class: Class I conforming to EN/IEC 61140; Class I conforming to NF C 20-030
IP degree of protection: IP65
Packing Units
Unit Type of Package 1: PCE
Number of Units in Package 1: 1
Package 1 Height: 20.5 cm
Package 1 Width: 15.5 cm
Package 1 Length: 9 cm
Package 1 Weight: 1.597 kg
Offer Sustainability
Sustainable offer status: Green Premium product
REACh Regulation: Reference contains Substances of Very High Concern above the threshold
EU RoHS Directive: Pro-active compliance (Product out of EU RoHS legal scope)
Mercury free: Yes
RoHS exemption information: Yes
Environmental Disclosure: ENVPEP111159EN
Circularity Profile: N/A
© 2018 Alplan Kft.