Skip to main content

Schneider-Electric
XPSUAK32AP

Preventa biztonsági relé modul, XSPUAF+bizt. szőnyeg funkció, Cat.4, bizt. be/ki: 2/3CO, PNP, 48-230VAC/DC, csavaros
Net discounted price 186.91 EUR
Available when ordered (delivery time: 118 working day(s))
Barcode: 3606489601676
Tariff code: 8536419089

Link to the manufacturers site: XPSUAK32AP - Preventa biztonsági relé modul, XSPUAF+bizt. szőnyeg funkció, Cat.4, bizt. be/ki: 2/3CO, PNP, 48-230VAC/DC, csavaros

Main

Range of produc: Harmony Safety Automation

Product or component type: Safety module

safety module name: XPSUAK

safety module application: Monitoring antivalent contacts; For emergency stop, guard and light curtain monitoring; Monitoring of pressure-sensitive 4-wire protective devices

function of module: Emergency stop button with 2 NC contacts; Guard monitoring with 1 or 2 limit switches; Monitoring 2 PNP sensors; Magnetic switch monitoring; Light curtain monitoring; RFID switch; Monitoring of electro-sensitive protection equipment (ESPE); Sensing mat/edges; Proximity sensor monitoring; Monitoring 1 PNP + 1 NPN sensor

Safety level: Can reach PL e/category 4 for normally open relay contact conforming to ISO 13849-1; Can reach SILCL 3 for normally open relay contact conforming to IEC 62061; Can reach SIL 3 for normally open relay contact conforming to IEC 61508; Can reach PL c/category 1 for normally closed relay contact conforming to ISO 13849-1; Can reach SILCL 1 for normally closed relay contact conforming to IEC 62061; Can reach SIL 1 for normally closed relay contact conforming to IEC 61508

Safety reliability data: MTTFd > 30 years conforming to ISO 13849-1; Dcavg >= 99 % conforming to ISO 13849-1; PFHd = 1.61E-09 conforming to ISO 13849-1; HFT = 1 conforming to IEC 62061; PFHd = 1.61E-09 conforming to IEC 62061; SFF > 99% conforming to IEC 62061; HFT = 1 conforming to IEC 61508-1; PFHd = 1.61E-09 conforming to IEC 61508-1; SFF > 99% conforming to IEC 61508-1; Type = B conforming to IEC 61508-1

Electrical circuit type: NC pair; PNP pair; Antivalent pair; OSSD pair

Connections - terminals: Removable screw terminal block, 0.2...2.5 mm² solid or flexible; Removable screw terminal block, 0.25...2.5 mm² flexible with ferrule single conductor; Removable screw terminal block, 0.2...1.5 mm² solid or flexible twin conductor; Removable screw terminal block, 2 x 0.25...1 mm² flexible with ferrule without cable end, with bezel; Removable screw terminal block, 2 x 0.5...1.5 mm² flexible with ferrule with cable end, with bezel

[Us] rated supply voltage: 48...240 V AC/DC - 10...10 %

Complementary

Synchronisation time between inputs: 0.5 s; 2 s; 4 s

Type of start: Automatic/manual/monitored

Power consumption in W: 3.0 W 48 V DC

Power consumption in VA: 6.5 VA 240 V AC 50/60 Hz

Input protection type: Internal, electronic

Auxiliary contact composition: 2 NO + 1 NC

Number of inputs: 2 safety input 24 V DC 5 mA

Maximum line resistance: 500 Ohm

Input compatibility: Normally closed circuit conforming to ISO 14119; XC limit switch conforming to ISO 14119; Mechanical contact conforming to ISO 14119; Normally closed circuit conforming to ISO 13850; Antivalent pair conforming to ISO 14119; OSSD pair conforming to IEC 61496-1-2; 3-wire proximity sensors PNP

[Ie] rated operational current: 5 A AC-1 for normally open relay contact; 3 A AC-15 for normally open relay contact; 5 A DC-1 for normally open relay contact; 3 A DC-13 for normally open relay contact; 3 A AC-1 for normally closed relay contact; 1 A AC-15 for normally closed relay contact; 3 A DC-1 for normally closed relay contact; 1 A DC-13 for normally closed relay contact

Number of outputs: 3 on/off configurable pulsed output

Input/output type: Semiconductor pulsed diagnostic output 24 V DC, 20 mA Z1, not safety-related

[Ith] conventional free air thermal current: 8 A

Associated fuse rating: 10 A gG for NO relay output circuit conforming to IEC 60947-1

Minimum output current: 10 mA for relay output

Minimum output voltage: 12 V for relay output

[Ui] rated insulation voltage: 250 V (pollution degree 2) conforming to IEC 60947-1

[Uimp] rated impulse withstand voltage: 4 kV overvoltage category II conforming to IEC 60947-1

mounting support: 35 mm symmetrical DIN rail

Depth: 120 mm

height: 100 mm

Width: 22.5 mm

Net weight: 0.200 kg

Environment

ambient air temperature for operation: -25…55 °C

Standards: IEC 60947-5-1; IEC 61508-1 functional safety standard; IEC 61508-2 functional safety standard; IEC 61508-3 functional safety standard; IEC 61508-4 functional safety standard; IEC 61508-5 functional safety standard; IEC 61508-6 functional safety standard; IEC 61508-7 functional safety standard; ISO 13849-1 functional safety standard; IEC 62061 functional safety standard

product certifications: TÜV; cULus

IP degree of protection: IP20 (terminals) conforming to IEC 60529; IP40 (housing) conforming to IEC 60529; IP54 (mounting area) conforming to IEC 60529

Relative humidity: 5…95 % non-condensing

Packing Units

Unit Type of Package 1: PCE

Number of Units in Package 1: 1

Package 1 Height: 7.000 cm

Package 1 Width: 14.000 cm

Package 1 Length: 16.000 cm

Package 1 Weight: 291.000 g

Unit Type of Package 2: S03

Number of Units in Package 2: 16

Package 2 Height: 30.000 cm

Package 2 Width: 30.000 cm

Package 2 Length: 40.000 cm

Package 2 Weight: 5.382 kg

Unit Type of Package 3: P06

Number of Units in Package 3: 128

Package 3 Height: 75.000 cm

Package 3 Width: 60.000 cm

Package 3 Length: 80.000 cm

Package 3 Weight: 51.056 kg

Offer Sustainability

Sustainable offer status: Green Premium product

REACh Regulation: Reference contains Substances of Very High Concern above the threshold

EU RoHS Directive: Pro-active compliance (Product out of EU RoHS legal scope)

Mercury free: Yes

China RoHS Regulation: X

RoHS exemption information: Yes

Environmental Disclosure: ENVPEP1811003EN

Circularity Profile: ENVEOLI1811003EN

WEEE: The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins

PVC free: Yes

© 2018 Alplan Kft.