Schneider-Electric
XPSUAK32AP
Tariff code: 8536419089
Link to the manufacturers site: XPSUAK32AP - Preventa biztonsági relé modul, XSPUAF+bizt. szőnyeg funkció, Cat.4, bizt. be/ki: 2/3CO, PNP, 48-230VAC/DC, csavaros
Main
Range of produc: Harmony Safety Automation
Product or component type: Safety module
safety module name: XPSUAK
safety module application: Monitoring antivalent contacts; For emergency stop, guard and light curtain monitoring; Monitoring of pressure-sensitive 4-wire protective devices
function of module: Emergency stop button with 2 NC contacts; Guard monitoring with 1 or 2 limit switches; Monitoring 2 PNP sensors; Magnetic switch monitoring; Light curtain monitoring; RFID switch; Monitoring of electro-sensitive protection equipment (ESPE); Sensing mat/edges; Proximity sensor monitoring; Monitoring 1 PNP + 1 NPN sensor
Safety level: Can reach PL e/category 4 for normally open relay contact conforming to ISO 13849-1; Can reach SILCL 3 for normally open relay contact conforming to IEC 62061; Can reach SIL 3 for normally open relay contact conforming to IEC 61508; Can reach PL c/category 1 for normally closed relay contact conforming to ISO 13849-1; Can reach SILCL 1 for normally closed relay contact conforming to IEC 62061; Can reach SIL 1 for normally closed relay contact conforming to IEC 61508
Safety reliability data: MTTFd > 30 years conforming to ISO 13849-1; Dcavg >= 99 % conforming to ISO 13849-1; PFHd = 1.61E-09 conforming to ISO 13849-1; HFT = 1 conforming to IEC 62061; PFHd = 1.61E-09 conforming to IEC 62061; SFF > 99% conforming to IEC 62061; HFT = 1 conforming to IEC 61508-1; PFHd = 1.61E-09 conforming to IEC 61508-1; SFF > 99% conforming to IEC 61508-1; Type = B conforming to IEC 61508-1
Electrical circuit type: NC pair; PNP pair; Antivalent pair; OSSD pair
Connections - terminals: Removable screw terminal block, 0.2...2.5 mm² solid or flexible; Removable screw terminal block, 0.25...2.5 mm² flexible with ferrule single conductor; Removable screw terminal block, 0.2...1.5 mm² solid or flexible twin conductor; Removable screw terminal block, 2 x 0.25...1 mm² flexible with ferrule without cable end, with bezel; Removable screw terminal block, 2 x 0.5...1.5 mm² flexible with ferrule with cable end, with bezel
[Us] rated supply voltage: 48...240 V AC/DC - 10...10 %
Complementary
Synchronisation time between inputs: 0.5 s; 2 s; 4 s
Type of start: Automatic/manual/monitored
Power consumption in W: 3.0 W 48 V DC
Power consumption in VA: 6.5 VA 240 V AC 50/60 Hz
Input protection type: Internal, electronic
Auxiliary contact composition: 2 NO + 1 NC
Number of inputs: 2 safety input 24 V DC 5 mA
Maximum line resistance: 500 Ohm
Input compatibility: Normally closed circuit conforming to ISO 14119; XC limit switch conforming to ISO 14119; Mechanical contact conforming to ISO 14119; Normally closed circuit conforming to ISO 13850; Antivalent pair conforming to ISO 14119; OSSD pair conforming to IEC 61496-1-2; 3-wire proximity sensors PNP
[Ie] rated operational current: 5 A AC-1 for normally open relay contact; 3 A AC-15 for normally open relay contact; 5 A DC-1 for normally open relay contact; 3 A DC-13 for normally open relay contact; 3 A AC-1 for normally closed relay contact; 1 A AC-15 for normally closed relay contact; 3 A DC-1 for normally closed relay contact; 1 A DC-13 for normally closed relay contact
Number of outputs: 3 on/off configurable pulsed output
Input/output type: Semiconductor pulsed diagnostic output 24 V DC, 20 mA Z1, not safety-related
[Ith] conventional free air thermal current: 8 A
Associated fuse rating: 10 A gG for NO relay output circuit conforming to IEC 60947-1
Minimum output current: 10 mA for relay output
Minimum output voltage: 12 V for relay output
[Ui] rated insulation voltage: 250 V (pollution degree 2) conforming to IEC 60947-1
[Uimp] rated impulse withstand voltage: 4 kV overvoltage category II conforming to IEC 60947-1
mounting support: 35 mm symmetrical DIN rail
Depth: 120 mm
height: 100 mm
Width: 22.5 mm
Net weight: 0.200 kg
Environment
ambient air temperature for operation: -25…55 °C
Standards: IEC 60947-5-1; IEC 61508-1 functional safety standard; IEC 61508-2 functional safety standard; IEC 61508-3 functional safety standard; IEC 61508-4 functional safety standard; IEC 61508-5 functional safety standard; IEC 61508-6 functional safety standard; IEC 61508-7 functional safety standard; ISO 13849-1 functional safety standard; IEC 62061 functional safety standard
product certifications: TÜV; cULus
IP degree of protection: IP20 (terminals) conforming to IEC 60529; IP40 (housing) conforming to IEC 60529; IP54 (mounting area) conforming to IEC 60529
Relative humidity: 5…95 % non-condensing
Packing Units
Unit Type of Package 1: PCE
Number of Units in Package 1: 1
Package 1 Height: 7.000 cm
Package 1 Width: 14.000 cm
Package 1 Length: 16.000 cm
Package 1 Weight: 291.000 g
Unit Type of Package 2: S03
Number of Units in Package 2: 16
Package 2 Height: 30.000 cm
Package 2 Width: 30.000 cm
Package 2 Length: 40.000 cm
Package 2 Weight: 5.382 kg
Unit Type of Package 3: P06
Number of Units in Package 3: 128
Package 3 Height: 75.000 cm
Package 3 Width: 60.000 cm
Package 3 Length: 80.000 cm
Package 3 Weight: 51.056 kg
Offer Sustainability
Sustainable offer status: Green Premium product
REACh Regulation: Reference contains Substances of Very High Concern above the threshold
EU RoHS Directive: Pro-active compliance (Product out of EU RoHS legal scope)
Mercury free: Yes
China RoHS Regulation: X
RoHS exemption information: Yes
Environmental Disclosure: ENVPEP1811003EN
Circularity Profile: ENVEOLI1811003EN
WEEE: The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
PVC free: Yes
© 2018 Alplan Kft.