Schneider-Electric
XPSAV11113
Tariff code:
This product is discontinued.
Please contact us for possible replacement product options.
Link to the manufacturers site: XPSAV11113 - module XPSAV - Emergency stop - 24 V DC, time delay 0...300 s
Main
range of product: Preventa Safety automation
product or component type: Preventa safety module
safety module name: XPSAV
safety module application: For emergency stop and switch monitoring
function of module: Emergency stop button with 2 NC contacts, monitored start; Emergency stop monitoring 2-channel wiring; Monitoring of a movable guard associated with 2 switches automatic start; Emergency stop button with 1 NC contact, automatic start or unmonitored start; Emergency stop monitoring 1-channel wiring
safety level: Can reach PL e/category 4 conforming to EN/ISO 13849-1; Can reach SILCL 3 conforming to EN/IEC 62061
safety reliability data: DC > 99 % conforming to EN/ISO 13849-1; MTTFd = 75.8 years conforming to EN/ISO 13849-1; PFHd = 7.95E-9 1/h conforming to EN/IEC 62061
type of start: Configurable
connections - terminals: Captive screw clamp terminals, 1 x 0.14...1 x 2.5 mm² flexible with cable end, with double bezel; Captive screw clamp terminals, 1 x 0.14...1 x 2.5 mm² solid with cable end, with double bezel; Captive screw clamp terminals, 1 x 0.25...1 x 1.5 mm² flexible with cable end, with double bezel; Captive screw clamp terminals, 1 x 0.25...1 x 2.5 mm² flexible with cable end, with double bezel; Captive screw clamp terminals, 2 x 0.14...2 x 0.75 mm² flexible with cable end, with double bezel; Captive screw clamp terminals, 2 x 0.14...2 x 0.75 mm² solid with cable end, with double bezel; Captive screw clamp terminals, 2 x 0.25...2 x 1 mm² flexible with cable end, with double bezel; Captive screw clamp terminals, 2 x 0.5...2 x 1.5 mm² flexible with cable end, with double bezel
output type: Relay instantaneous opening, 3 NO circuit(s), volt-free; Relay time delay opening, 3 NO circuit(s), volt-free
number of additional circuits: 3 solid state outputs
[Us] rated supply voltage: 24 V DC - 20...20 %
Complementary
synchronisation time between inputs: 1.5 s for guard; Unlimited for emergency stop
maximum power consumption in W: 5 W DC
input protection type: Internal, electronic
time delay range: 0...300 s
[Uc] control circuit voltage: 24 V DC
maximum line resistance: 100 Ohm <2000 m
breaking capacity: 180 VA holding AC-15 C300 relay output; 1800 VA inrush AC-15 C300 relay output
breaking capacity: 20 mA at 24 V; 1.25 A at 24 V (DC-13) time constant: 50 ms for relay output
output thermal current: 2 A for 1 output and 4 A for the other 2 outputs for instantaneous and time delay outputs; 3.3 A for all 3 outputs for instantaneous and time delay outputs; 6 A for 1 output and 2 A for the other 2 outputs for instantaneous and time delay outputs
[Ith] conventional free air thermal current: 20 A
associated fuse rating: 4 A gG or gL for instantaneous and time delay outputs conforming to EN/IEC 60947-5-1, DIN VDE 0660 part 200; 6 A fast blow conforming to EN/IEC 60947-5-1, DIN VDE 0660 part 200
minimum output current: 10 mA for relay output
minimum output voltage: 17 V for relay output
maximum response time on input open: 30 ms
[Ui] rated insulation voltage: 300 V (pollution degree 2) conforming to IEC 60947-5-1; 300 V (pollution degree 2) conforming to DIN VDE 0110 part 1
[Uimp] rated impulse withstand voltage: 4 kV overvoltage category III conforming to IEC 60947-5-1; 4 kV overvoltage category III conforming to DIN VDE 0110 part 1
local signalling: 11 LEDs
mounting support: 35 mm symmetrical DIN rail
net weight: 0.32 kg
Environment
standards: EN/ISO 13850; EN 1088/ISO 14119; EN/IEC 60947-5-1; EN/IEC 60204-1
product certifications: UL; TÜV; CSA
IP degree of protection: IP20 (terminals) conforming to EN/IEC 60529; IP40 (enclosure) conforming to EN/IEC 60529
ambient air temperature for operation: -10…55 °C
ambient air temperature for storage: -25…85 °C
Offer Sustainability
Sustainable offer status: Green Premium product
REACh Regulation: Free of Substances of Very High Concern above the threshold
EU RoHS Directive: Pro-active compliance (Product out of EU RoHS legal scope)
Mercury free: Yes
RoHS exemption information: Yes
China RoHS Regulation: X
Environmental Disclosure: ENVPEP1406024EN
Circularity Profile: ENVEOLI1406024EN
WEEE: The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
PVC free: Yes
© 2018 Alplan Kft.