Skip to main content

Schneider-Electric
RM22TU23

three-Phase Undervoltage control relay 380…480Vac, 2 C/O
Net discounted price 86.74 EUR
In stock: 2 pc(s)
Barcode: 3606480792175
Tariff code: 8536490099

Link to the manufacturers site: RM22TU23 - three-Phase Undervoltage control relay 380…480Vac, 2 C/O

Main

Range of produc: Harmony Control Relays

Relay type: Control relay

Product or component type: 3-phase control relay

Network number of phases: 3 phases

Relay name: RM22TR

Relay monitored parameters: Undervoltage detection; Phase sequence; Phase failure detection

Time delay type: Without

Switching capacity in VA: 2000 VA

Measurement range: 380...480 V voltage AC

Contacts type and composition: 2 C/O

Connections - terminals: Screw connectors

[Uc] control circuit voltage: 380...480 V

[In] rated current: 8 A

Complementary

Reset time: 1500 ms at maximum voltage

Maximum switching voltage: 250 V AC

Minimum switching current: 10 mA at 5 V DC

Maximum switching current: 8 A AC

Supply voltage limits: 304…576 V AC

Control circuit voltage limits: - 20 % + 20 % Un

Power consumption in VA: 15 VA at 480 V AC 60 Hz

Voltage detection threshold: < 100 V AC

Supply frequency: 50...60 Hz +/- 10 %

Output contacts: 2 C/O

Setting accuracy of the switching threshold: +/- 10 % of the full scale

Switching threshold drift: <= 0.05 % per degree centigrade depending permissible ambient air temperature; <= 1 % within the supply voltage range

Setting accuracy of time delay: 10 P

Time delay drift: <= 0.05 % per degree centigrade depending permissible ambient air temperature; <= 1 % within the supply voltage range

Hysteresis: 2 % fixed of selectable

run-up delay at power-up: 650 ms

Maximum measuring cycle: 150 ms measurement cycle as true rms value

Threshold adjustment voltage: 2...20 % of Un selected

Voltage range: 380...480 V phase to phase

Repeat accuracy: +/- 0.5 % for input and measurement circuit

Measurement error: < 1 % over the whole range with voltage variation; < 0.05 %/°C with temperature variation

Response time: <= 300 ms

Overvoltage category: III conforming to IEC 60664-1; III conforming to UL 508

Insulation resistance: > 100 MOhm at 500 V DC conforming to IEC 60255-27

Mounting position: Any position

Connections - terminals: Screw terminals, 2 x 0.5...2 x 2.5 mm² (AWG 20...AWG 14) solid without cable end; Screw terminals, 2 x 0.2...2 x 1.5 mm² (AWG 24...AWG 16) flexible with cable end; Screw terminals, 1 x 0.5...1 x 3.3 mm² (AWG 20...AWG 12) solid without cable end; Screw terminals, 1 x 0.2...1 x 2.5 mm² (AWG 24...AWG 14) flexible with cable end

Tightening torque: 0.6…1 N.m conforming to IEC 60947-1

Housing material: Self-extinguishing plastic

Status LED: LED (yellow) relay ON; LED (green) power ON

Mounting support: 35 mm DIN rail conforming to IEC 60715

Electrical durability: 100000 cycles

Mechanical durability: 10000000 cycles

Utilisation category: AC-15 conforming to IEC 60947-5-1; DC-13 conforming to IEC 60947-5-1; AC-1 conforming to IEC 60947-4-1; DC-1 conforming to IEC 60947-4-1

Safety reliability data: MTTFd = 388.1 years; B10d = 350000

Contacts material: Cadmium free

Width: 22.5 mm

Net weight: 0.09 kg

Compatibility code: RM22

Environment

Immunity to microbreaks: 10 ms

Electromagnetic compatibility: Immunity for residential, commercial and light-industrial environments conforming to IEC 61000-6-1; Immunity for industrial environments conforming to IEC 61000-6-2; Emission standard for residential, commercial and light-industrial environments conforming to IEC 61000-6-3; Emission standard for industrial environments conforming to IEC 61000-6-4; Electrostatic discharge - test level: 6 kV level 3 (contact discharge) conforming to IEC 61000-4-2; Electrostatic discharge - test level: 8 kV level 3 (air discharge) conforming to IEC 61000-4-2; Radiated radio-frequency electromagnetic field immunity test - test level: 10 V/m level 3 conforming to IEC 61000-4-3; Electrical fast transient/burst immunity test - test level: 4 kV level 4 (direct) conforming to IEC 61000-4-4; Electrical fast transient/burst immunity test - test level: 2 kV level 4 (capacitive coupling) conforming to IEC 61000-4-4; Surge immunity test - test level: 4 kV level 4 (common mode) conforming to IEC 61000-4-5; Surge immunity test - test level: 2 kV level 4 (differential mode) conforming to IEC 61000-4-5; Conducted and radiated emissions class B group 1 conforming to CISPR 11; Conducted and radiated emissions class B conforming to CISPR 22

Standards: IEC 60255-1

product certifications: CSA; RCM; UL; GL; CE; CCC; EAC

Ambient air temperature for storage: -40…70 °C

Ambient air temperature for operation: -20…50 °C at 60 Hz; -20…60 °C at 50 Hz AC/DC

Relative humidity: 93…97 % at 25…55 °C conforming to IEC 60068-2-30

Vibration resistance: 0.075 mm (f= 10…58.1 Hz) not in operation conforming to IEC 60068-2-6; 1 gn (f= 10…58.1 Hz) not in operation conforming to IEC 60068-2-6; 0.035 mm (f= 58.1…150 Hz) in operation conforming to IEC 60068-2-6; 0.5 gn (f= 58.1…150 Hz) in operation conforming to IEC 60068-2-6

Shock resistance: 15 gn (duration = 11 ms) for not in operation conforming to IEC 60068-2-27; 5 gn (duration = 11 ms) for in operation conforming to IEC 60068-2-27

IP degree of protection: IP20 (terminals) conforming to IEC 60529; IP40 (housing) conforming to IEC 60529; IP50 (front panel) conforming to IEC 60529

Pollution degree: 3 conforming to IEC 60664-1; 3 conforming to UL 508

Dielectric test voltage: 2.5 kV, 1 min AC 50 Hz conforming to IEC 60255-27

Packing Units

Unit Type of Package 1: PCE

Number of Units in Package 1: 1

Package 1 Height: 2.6 cm

Package 1 Width: 8.2 cm

Package 1 Length: 9.5 cm

Package 1 Weight: 103.0 g

Unit Type of Package 2: S02

Number of Units in Package 2: 40

Package 2 Height: 15.0 cm

Package 2 Width: 30.0 cm

Package 2 Length: 40.0 cm

Package 2 Weight: 4.656 kg

Unit Type of Package 3: P06

Number of Units in Package 3: 640

Package 3 Height: 75.0 cm

Package 3 Width: 60.0 cm

Package 3 Length: 80.0 cm

Package 3 Weight: 82.996 kg

Offer Sustainability

Sustainable offer status: Green Premium product

REACh Regulation: Reference contains Substances of Very High Concern above the threshold

EU RoHS Directive: Pro-active compliance (Product out of EU RoHS legal scope)

Mercury free: Yes

China RoHS Regulation: X

RoHS exemption information: Yes

Environmental Disclosure: ENVPEP1504008EN

Circularity Profile: ENVEOLI1504008EN

© 2018 Alplan Kft.