Schneider-Electric
RE22R2MMW
Tariff code: 8536490099
Link to the manufacturers site: RE22R2MMW - Multifunction Timer Relay - 12..240 V AC/DC - 2 C/O
Main
Range of produc: Harmony Timer Relays
Product or component type: Multifunction relay
Discrete output type: Relay
Device short name: RE22
Nominal output current: 8 A
[Uc] control circuit voltage: 12...240 V
Contacts type and composition: 2 C/O
Connections - terminals: Screw connectors
[In] rated current: 5 A
Output type: Relay
Complementary
Contacts type and composition: 1 C/O timed contact; 1 C/O timed or instantaneous contact
Time delay type: Power on-delay; On-delay and off-delay; Interval; Off-delay; Symmetrical flashing
Time delay range: 0.1...1 s; 6...60 s; 1...10 h; 1...10 min; 1...10 s; 10...100 h; 6...60 min
Control type: Rotary knob front panel
[Us] rated supply voltage: 12...240 V AC/DC
Voltage range: 0.85...1.1 Us
Supply frequency: 50...60 Hz +/- 5 %
Connections - terminals: Screw terminals, 2 x 1.5 mm² with cable end; Screw terminals, 2 x 2.5 mm² without cable end
Tightening torque: 0.6…1 N.m conforming to IEC 60947-1
Housing material: Self-extinguishing
Repeat accuracy: +/- 0.5 % conforming to IEC 61812-1
Temperature drift: +/- 0.05 %/°C
Voltage drift: +/- 0.2 %/V
Setting accuracy of time delay: +/- 10 % of full scale at 25 °C conforming to IEC 61812-1
Minimum pulse duration: 30 ms; 100 ms under load
Insulation resistance: 100 MOhm at 500 V DC conforming to IEC 60664-1
Reset time: 120 ms on de-energisation
Immunity to microbreaks: 10 ms
Power consumption in VA: 3 VA at 240 V AC
Power consumption in W: 1.5 W at 240 V DC
Breaking capacity: 2000 VA
Minimum switching current: 10 mA at 5 V
Maximum switching current: 8 A
Maximum switching voltage: 250 V
Electrical durability: 100000 cycles for resistive load, 8 A at 250 V, AC
Mechanical durability: 10000000 cycles
[Uimp] rated impulse withstand voltage: 5 kV for 1.2…50 µs conforming to IEC 60664-1; 5 kV conforming to IEC 61812-1
Maximum delay response: 100 ms
Safety reliability data: B10d = 230000; MTTFd = 251.1 years
Mounting position: Any position in relation to normal vertical mounting plane
Mounting support: 35 mm DIN rail conforming to IEC 60715
Status LED: LED green (flashing) for timing in progress; LED green (steady) for power ON; LED yellow for relay energised
Width: 22.5 mm
Net weight: 0.093 kg
Time delay type: A, Ac, At, B, Bw, C, D, Di, H
Contacts type and composition: 2 C/O
Functionality: Multifunction
Environment
Dielectric strength: 2.5 kV for 1 mA/1 minute at 50 Hz conforming to IEC 61812-1
Standards: IEC 61812-1; IEC 61000-6-2; IEC 61000-6-1; IEC 61000-6-4; IEC 61000-6-3
Directives: 2004/108/EC - electromagnetic compatibility; 2006/95/EC - low voltage directive
product certifications: CSA; CE; cULus; GL; RCM; CCC; EAC
ambient air temperature for operation: -20…60 °C
Ambient air temperature for storage: -30…60 °C
IP degree of protection: IP40 housing: conforming to IEC 60529; IP20 terminal block: conforming to IEC 60529; IP40 front face: conforming to IEC 60529
Vibration resistance: 20 m/s² (f= 10…150 Hz) conforming to IEC 60068-2-6
Shock resistance: 15 gn for 11 ms conforming to IEC 60068-2-27
Relative humidity: 93 %, without condensation conforming to IEC 60068-2-30
Electromagnetic compatibility: Electrostatic discharge immunity test - test level: 6 kV level 3 (contact discharge) conforming to IEC 61000-4-2; Electrostatic discharge immunity test - test level: 8 kV level 3 (air discharge) conforming to IEC 61000-4-2; Fast transients immunity test - test level: 1 kV level 3 (capacitive connecting clip) conforming to IEC 61000-4-4; Fast transients immunity test - test level: 2 kV level 3 (direct contact) conforming to IEC 61000-4-4; Surge immunity test - test level: 1 kV level 3 (differential mode) conforming to IEC 61000-4-5; Surge immunity test - test level: 2 kV level 3 (common mode) conforming to IEC 61000-4-5; Radiated radio-frequency electromagnetic field immunity test - test level: 10 V level 3 (0.15...80 MHz) conforming to IEC 61000-4-6; Electromagnetic field immunity test - test level: 10 V/m level 3 (80 MHz...1 GHz) conforming to IEC 61000-4-3; Immunity to microbreaks and voltage drops - test level: 30 % (500 ms) conforming to IEC 61000-4-11; Immunity to microbreaks and voltage drops - test level: 100 % (20 ms) conforming to IEC 61000-4-11; Conducted and radiated emissions class B conforming to EN 55022
Packing Units
Unit Type of Package 1: PCE
Number of Units in Package 1: 1
Package 1 Height: 2.500 cm
Package 1 Width: 8.300 cm
Package 1 Length: 9.600 cm
Package 1 Weight: 107.000 g
Unit Type of Package 2: S02
Number of Units in Package 2: 40
Package 2 Height: 15.000 cm
Package 2 Width: 30.000 cm
Package 2 Length: 40.000 cm
Package 2 Weight: 4.800 kg
Offer Sustainability
Sustainable offer status: Green Premium product
REACh Regulation: Reference contains Substances of Very High Concern above the threshold
EU RoHS Directive: Pro-active compliance (Product out of EU RoHS legal scope)
Mercury free: Yes
China RoHS Regulation: X
RoHS exemption information: Yes
Environmental Disclosure: ENVPEP1401008EN