Skip to main content

Schneider-Electric
LV432074

trip unit Micrologic 6.3 E-M for Compact NSX 630 circuit breakers, electronic, rating 500 A, 3 poles 3d
Barcode: 3606480017582
Tariff code: 8536309090

This product is discontinued.

Please contact us for possible replacement product options.

Link to the manufacturers site: LV432074 - trip unit Micrologic 6.3 E-M for Compact NSX 630 circuit breakers, electronic, rating 500 A, 3 poles 3d

Main

Range: ComPact

Range of product: ComPact NSX400...630

Product name: Micrologic

Product or component type: Trip unit

Trip unit name: Micrologic 6.3 E-M

Trip unit technology: Electronic

Range compatibility: ComPact NSX630

Device application: Motor

Poles description: 3P

Protected poles description: 3t

Trip unit protection functions: LSIG

Protection type: L : for overload protection (long time); S : for short time short-circuit protection; I : for instantaneous short-circuit protection; G : for ground fault protection

[In] rated current: 500 A at 65 °C

[Ue] rated operational voltage: 690 V AC 50/60 Hz

Network type: AC

Network frequency: 50/60 Hz

Complementary

Motor tripping class: 5; 10; 30; 20

Complementary motor protection: Current unbalance; Protracted starting time; Stalled rotor; Underload

Long time pick-up adjustment type Ir: Adjustable 9 settings

long time pick-up adjustment range: 250...500 A

long time delay adjustment type: Adjustable

[tr] long-time delay adjustment range: 120 s at 1.5 x Ir for trip class 5; 6.5 s at 6 x Ir for trip class 5; 5 s at 7.2 x Ir for trip class 5; 240 s at 1.5 x Ir for trip class 10; 13.5 s at 6 x Ir for trip class 10; 10 s at 7.2 x Ir for trip class 10; 480 s at 1.5 x Ir for trip class 20; 26 s at 6 x Ir for trip class 20; 20 s at 7.2 x Ir for trip class 20; 720 s at 1.5 x Ir for trip class 30; 38 s at 6 x Ir for trip class 30; 30 s at 7.2 x Ir for trip class 30

Thermal memory: 20 minutes before and after tripping

Short-time pick-up adjustment type Isd: Adjustable 9 settings

[Isd] short-time pick-up adjustment range: 5...13 x Ir

Short-time delay adjustment type: Fixed

[tsd] short-time delay adjustment range: 0.01 s

Instantaneous pick-up adjustment type Ii: Fixed

Instantaneous pick-up adjustment range: 6500 A

Ground-fault pick-up adjustment type: Adjustable

[Ig] ground-fault pick-up adjustment range: 0.2...1 x In for In > 50 A; 0.3...1 x In for In = 50 A; 0.6...1 x In for In = 25 A; Ig enable on/off

Ground-fault time delay adjustment type -tg: Adjustable

[tg] Ground-fault time delay adjustment range: 0…0.4 s

Earth-leakage protection: Without

Zone selective interlocking ZSI: With

Local signalling: Flashing LED (green) for ready to operate; LED 95 % Ith (red) for temperature over set point

Display type: LCD display

type of measurement: Energy meter

Electrical data recording: Maintenance indicators

Environment

Standards: EN/IEC 60947-2; UL 508

Product certifications: Marine; CCC; EAC

Ambient air temperature for operation: -25…70 °C

Ambient air temperature for storage: -40…85 °C

Packing Units

Unit Type of Package 1: Db

Number of Units in Package 1: 1

Package 1 Height: 13.5 cm

Package 1 Width: 17.8 cm

Package 1 Length: 22.0 cm

Package 1 Weight: 1.494 kg

Unit Type of Package 2: S04

Number of Units in Package 2: 6

Package 2 Height: 30.0 cm

Package 2 Width: 40.0 cm

Package 2 Length: 60.0 cm

Package 2 Weight: 9.73 kg

Offer Sustainability

Sustainable offer status: Green Premium product

EU RoHS Directive: Compliant

Mercury free: Yes

China RoHS Regulation: Product out of China RoHS scope. Substance declaration for your information

RoHS exemption information: Yes

Environmental Disclosure: ENVPEP120606EN

Circularity Profile: ENVEOLI120604EN

© 2018 Alplan Kft.