Skip to main content

Schneider-Electric
LV426250

circuit breaker Compact NSXm B (25 kA at 415 VAC), 3P, 16 A rating TMD trip unit, compression lugs and busbar connectors
Barcode: 3606481174369
Tariff code: 8536209090

This product is discontinued.

Please contact us for possible replacement product options.

Link to the manufacturers site: LV426250 - circuit breaker Compact NSXm B (25 kA at 415 VAC), 3P, 16 A rating TMD trip unit, compression lugs and busbar connectors

Main

Range: ComPact

Product name: ComPact NSXm

Range of product: ComPact NSXm

Device short name: NSXm 16B

Product or component type: Circuit breaker

Device application: Protection; Distribution

Poles description: 3P

Protected poles description: 3D

[In] rated current: 16 A at 40 °C

[Ue] rated operational voltage: 690 V AC 50/60 Hz

Network type: AC

Network frequency: 50/60 Hz

Suitability for isolation: Yes conforming to EN/IEC 60947-2

Utilisation category: Category A

Breaking capacity: 50 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2; 25 kA Icu at 380...415 V AC 50/60 Hz conforming to IEC 60947-2; 20 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2; 10 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2

Breaking capacity code: B 25 kA 415 V AC

Trip unit name: TM-D

Trip unit technology: Thermal-magnetic

Trip unit protection functions: LI

control type: Toggle

Mounting mode: By screws; Clip-on

Complementary

[Ui] rated insulation voltage: 800 V AC 50/60 Hz

[Uimp] rated impulse withstand voltage: 8 kV

[Ics] rated service breaking capacity: 50 kA at 220...240 V AC 50/60 Hz conforming to IEC 60947-2; 25 kA at 380...415 V AC 50/60 Hz conforming to IEC 60947-2; 20 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2; 10 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2

Mechanical durability: 20000 cycles

Electrical durability: 10000 cycles at 440 V In; 20000 cycles at 440 V In/2; 5000 cycles at 690 V In; 10000 cycles at 690 V In/2

Mounting support: Plate; DIN rail

Connections - terminals: compression lug/busbar

Connection pitch: 35 mm with spreaders; 27 mm without spreaders

9 mm pitches: 9 module

Protection type: L : for overload protection (thermal); I : for short-circuit protection (magnetic)

Trip unit rating: 16 A at 40 °C

Long time pick-up adjustment type Ir: Adjustable

long time pick-up adjustment range: 0.7...1 x In

long time delay adjustment type: Fixed

Magnetic tripping current: 500 A

Earth-leakage protection: Without

Number of slots: 1 slot(s) for auxiliary switch OF; 1 slot(s) for alarm switch SD; 1 slot(s) for voltage release MN or MX

Width: 81 mm

Height: 137 mm

Depth: 80 mm

Net weight: 1.06 kg

Colour: Grey (RAL 7016)

Environment

Standards: EN/IEC 60947

Product certifications: CCC; EAC; Marine

Pollution degree: 3 conforming to IEC 60664-1

IP degree of protection: IP40 conforming to IEC 60529

IK degree of protection: IK07 conforming to IEC 62262

Ambient air temperature for operation: -25…70 °C

Ambient air temperature for storage: -50…85 °C

Relative humidity: 0…95 %

Operating altitude: 0...2000 m without derating; 2000...5000 m with derating

Packing Units

Unit Type of Package 1: Db

Number of Units in Package 1: 1

Package 1 Height: 9.0 cm

Package 1 Width: 22.0 cm

Package 1 Length: 12.5 cm

Package 1 Weight: 1.3 kg

Offer Sustainability

Sustainable offer status: Green Premium product

EU RoHS Directive: Compliant

Mercury free: Yes

China RoHS Regulation: Product out of China RoHS scope. Substance declaration for your information

RoHS exemption information: Yes

Environmental Disclosure: ENVPEP1607007EN

WEEE: The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins