Skip to main content

Schneider-Electric
LUCCX6BL

advanced control unit LUCC - class 10 - 0.15...0.6 A - 24 V DC
In stock: 4 pc(s)
Barcode: 3389110364460
Tariff code:

This product is discontinued.

This product is no longer manufactured, but we have it in stock. Please contact us for price and delivery information!

Link to the manufacturers site: LUCCX6BL - advanced control unit LUCC - class 10 - 0.15...0.6 A - 24 V DC

Main

range: TeSys

range of product: TeSys U

product name: TeSys U

device short name: LUCC

product or component type: Advanced control unit

device application: Motor control; Motor protection

product specific application: Basic protection and advanced functions, communication

function available: Protection against phase failure and phase imbalance; Protection against overload and short-circuit; Earth fault protection; Manual reset

product compatibility: Power base LUB12; Power base LUB32; Power base LUB38; Power base LUB120; Power base LUB320; Power base LUB380; Reversing contactor breaker LU2B12BL; Reversing contactor breaker LU2B32BL; Reversing contactor breaker LU2B38BL

[Ue] rated operational voltage: 690 V AC

network frequency: 40...60 Hz

load type: Single-phase motor

utilisation category: AC-43; AC-41; AC-44

thermal protection adjustment range: 0.15…0.6 A

thermal overload class: Class 10 - frequency limit: 40…60 Hz - temperature compensation: -25…55 °C conforming to IEC 60947-6-2; Class 10 - frequency limit: 40…60 Hz - temperature compensation: -25…55 °C conforming to UL 508

tripping threshold: 14.2 x Ir +/- 20 %

[Uc] control circuit voltage: 24 V DC

Complementary

control circuit voltage limits: 20...27 V for DC circuit 24 V in operation; 14.5 V for DC circuit 24 V drop-out

typical current consumption: 130 mA at 24 V DC I maximum while closing with LUB12; 220 mA at 24 V DC I maximum while closing with LUB32; 220 mA at 24 V DC I maximum while closing with LUB38; 60 mA at 24 V DC I rms sealed with LUB12; 80 mA at 24 V DC I rms sealed with LUB32; 80 mA at 24 V DC I rms sealed with LUB38

heat dissipation: 2 W for control circuit with LUB12; 3 W for control circuit with LUB32; 3 W for control circuit with LUB38

operating time: 35 ms opening with LUB12 for control circuit; 35 ms opening with LUB32 for control circuit; 35 ms opening with LUB38 for control circuit; 70 ms closing with LUB12 for control circuit; 70 ms closing with LUB32 for control circuit; 70 ms closing with LUB38 for control circuit

reset: Manual reset

standards: EN 60947-6-2; IEC 60947-6-2; UL 60947-4-1, with phase barrier; CSA C22.2 No 60947-4-1, with phase barrier

product certifications: CE; UL; CSA; CCC; EAC; ASEFA; ATEX; Marine

[Ui] rated insulation voltage: 690 V conforming to IEC 60947-6-2; 600 V conforming to UL 60947-4-1; 600 V conforming to CSA C22.2 No 60947-4-1

[Uimp] rated impulse withstand voltage: 6 kV conforming to IEC 60947-6-2

safe separation of circuit: 400 V SELV between the control and auxiliary circuits conforming to IEC 60947-1; 400 V SELV between the control or auxiliary circuit and the main circuit conforming to IEC 60947-1

fixing mode: Plug-in (front face)

width: 45 mm

height: 66 mm

depth: 60 mm

compatibility code: LUCC

Environment

IP degree of protection: IP20 front panel and wired terminals conforming to IEC 60947-1; IP20 other faces conforming to IEC 60947-1; IP40 front panel outside connection zone conforming to IEC 60947-1

protective treatment: TH conforming to IEC 60068

ambient air temperature for operation: -25…70 °C

ambient air temperature for storage: -40…85 °C

operating altitude: 2000 m

fire resistance: 960 °C parts supporting live components conforming to IEC 60695-2-12; 650 °C conforming to IEC 60695-2-12

shock resistance: 10 gn power poles open conforming to IEC 60068-2-27; 15 gn power poles closed conforming to IEC 60068-2-27

vibration resistance: 2 gn, 5…300 Hz, power poles open conforming to IEC 60068-2-6; 4 gn, 5…300 Hz, power poles closed conforming to IEC 60068-2-6

resistance to electrostatic discharge: 8 kV level 3 in open air conforming to IEC 61000-4-2; 8 kV level 4 on contact conforming to IEC 61000-4-2

resistance to radiated fields: 10 V/m 3 conforming to IEC 61000-4-3

resistance to fast transients: 2 kV class 3 serial link conforming to IEC 61000-4-4; 4 kV class 4 all circuits except for serial link conforming to IEC 61000-4-4

immunity to radioelectric fields: 10 V conforming to IEC 61000-4-6

immunity to microbreaks: 3 ms

immunity to voltage dips: 70 % / 500 ms conforming to IEC 61000-4-11

Offer Sustainability

Sustainable offer status: Green Premium product

REACh Regulation: Free of Substances of Very High Concern above the threshold

EU RoHS Directive: Compliant

Mercury free: Yes

RoHS exemption information: Yes

China RoHS Regulation: Product out of China RoHS scope. Substance declaration for your information

Environmental Disclosure: ENVPEP080204EN

Circularity Profile: ENVEOLI100414

WEEE: The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins

PVC free: Yes

Halogen content performance: Halogen free plastic parts product

© 2018 Alplan Kft.