Skip to main content

Schneider-Electric
LC3K06P7

TeSys K - star delta starter - 3 x 3P (3 NO) - 6 A - 230 V AC coil
Barcode: 3389118156609
Tariff code:

This product is discontinued.

Please contact us for possible replacement product options.

Link to the manufacturers site: LC3K06P7 - TeSys K - star delta starter - 3 x 3P (3 NO) - 6 A - 230 V AC coil

Main

range of product: TeSys K

range: TeSys

product name: TeSys K

product or component type: Star delta starter

device short name: LC3K

contactor application: Motor control

utilisation category: AC-3

device presentation: Pre-wired

poles description: 3 x 3P

pole contact composition: 3 x 3 NO

[Ue] rated operational voltage: Power circuit: <= 690 V AC 25...400 Hz

[Ie] rated operational current: 6 A (at <50 °C) at <= 440 V AC AC-3 for power circuit

motor power kW: 3 kW at 220/230 V AC 50/60 Hz; 5.5 kW at 380/400 V AC 50/60 Hz; 5.5 kW at 415 V AC 50/60 Hz; 5.5 kW at 440 V AC 50/60 Hz

control circuit type: AC at 50/60 Hz

[Uc] control circuit voltage: 230 V AC 50/60 Hz

auxiliary contact composition: 1 NC for KM1 star contactor

[Uimp] rated impulse withstand voltage: 8 kV

overvoltage category: III

[Ui] rated insulation voltage: Power circuit: 750 V conforming to VDE 0110 group C; Power circuit: 690 V conforming to IEC 60947; Power circuit: 690 V conforming to BS 5424; Power circuit: 690 V conforming to NF C 20-040; Power circuit: 600 V CSA 22-2 certified; Power circuit: 600 V UL 508 certified; Signalling circuit: 750 V conforming to VDE 0110 group C; Signalling circuit: 690 V conforming to IEC 60947; Signalling circuit: 690 V conforming to BS 5424; Signalling circuit: 690 V conforming to NF C 20-040; Signalling circuit: 600 V CSA 22-2 certified; Signalling circuit: 600 V UL 508 certified

electrical durability: 1.3 Mcycles 6 A AC-3 at Ue <= 440 V

interlocking type: Mechanical

mounting support: Rail

standards: NF C 63-110; IEC 60947; VDE 0660

product certifications: CSA; UL

Complementary

connections - terminals: Screw clamp terminals 1 1.5…4 mm² - cable stiffness: solid; Screw clamp terminals 1 0.75…4 mm² - cable stiffness: flexible without cable end; Screw clamp terminals 1 0.34…2.5 mm² - cable stiffness: flexible with cable end; Screw clamp terminals 2 1.5…4 mm² - cable stiffness: solid; Screw clamp terminals 2 0.75…4 mm² - cable stiffness: flexible without cable end; Screw clamp terminals 2 0.34…1.5 mm² - cable stiffness: flexible with cable end

tightening torque: 1.3 N.m - on screw clamp terminals - with screwdriver Philips No 2; 1.3 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm

mechanical durability: 10 Mcycles

maximum operating rate: 12 cyc/h 60 °C

starting time: 30 s

coil technology: Without built-in suppressor module

control circuit voltage limits: Operational: 0.8...1.15 Uc (at <50 °C); Drop-out: 0.2...0.75 Uc (at <50 °C)

inrush power in VA: 30 VA (at 20 °C)

hold-in power consumption in VA: 4.5 VA (at 20 °C)

heat dissipation: 1.3 W

auxiliary contacts type: Mechanically linked conforming to IEC 60947-5-1 3 x 1 NO + 1 NC; Mirror contact conforming to IEC 60947-4-1 3 x 1 NC

minimum switching current: 5 mA for signalling circuit

switching voltage: 17 V for signalling circuit

width: 150 mm

height: 110 mm

depth: 94 mm

net weight: 0.74 kg

power range: 0…0.5 kW at 200…240 V 3 phases; 0.55…1 kW at 200…240 V 3 phases; 1.1…2 kW at 200…240 V 3 phases; 2.2…3 kW at 200…240 V 3 phases; 0…0.5 kW at 380…440 V 3 phases; 0.55…1 kW at 380…440 V 3 phases; 1.1…2 kW at 380…440 V 3 phases; 2.2…3 kW at 380…440 V 3 phases; 4…6 kW at 380…440 V 3 phases

motor starter type: Star delta starter

contactor coil voltage: 230 V AC standard

Environment

insulation resistance: > 10 MOhm for signalling circuit

IP degree of protection: IP20 conforming to VDE 0106

protective treatment: TC conforming to IEC 60068; TC conforming to DIN 50016

ambient air temperature for storage: -50…80 °C

operating altitude: 2000 m without derating

flame retardance: V1 conforming to UL 94; Requirement 2 conforming to NF F 16-101; Requirement 2 conforming to NF F 16-102

mechanical robustness: Vibrations contactor open: 2 Gn, 5...300 Hz; Vibrations contactor closed: 4 Gn, 5...300 Hz; Shocks contactor closed, on X axis: 10 Gn for 11 ms; Shocks contactor opened, on X axis: 6 Gn for 11 ms; Shocks contactor closed, on Y axis: 15 Gn for 11 ms; Shocks contactor opened, on Y axis: 10 Gn for 11 ms; Shocks contactor closed, on Z axis: 15 Gn for 11 ms; Shocks contactor opened, on Z axis: 10 Gn for 11 ms

Offer Sustainability

Sustainable offer status: Green Premium product

REACh free of SVHC: Yes

EU RoHS Directive: Compliant

Toxic heavy metal free: Yes

Mercury free: Yes

RoHS exemption information: Yes

China RoHS Regulation:  Pro-active China RoHS declaration (out of China RoHS legal scope)

Environmental Disclosure: ENVPEP1503003EN

Circularity Profile: ENVEOLI1503003EN

WEEE: The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins

© 2018 Alplan Kft.