Schneider-Electric
LC2D115004P7
Tariff code:
This product is discontinued.
Please contact us for possible replacement product options.
Link to the manufacturers site: LC2D115004P7 - TeSys D changeover contactor - 4P(4 NO) - AC-1 - <= 440 V 200 A - 230 V AC coil
Main
range of product: TeSys D
range: TeSys
product name: TeSys D
product or component type: Changeover contactor
device short name: LC2D
contactor application: Resistive load
utilisation category: AC-1
device presentation: Preassembled with reversing power busbar
poles description: 4P
pole contact composition: 4 NO
[Ue] rated operational voltage: Power circuit: <= 1000 V AC 25...400 Hz; Power circuit: <= 460 V DC
[Ie] rated operational current: 200 A (at <60 °C) at <= 440 V AC AC-1 for power circuit
control circuit type: AC at 50/60 Hz
[Uc] control circuit voltage: 230 V AC 50/60 Hz
[Uimp] rated impulse withstand voltage: 8 kV conforming to IEC 60947
overvoltage category: III
[Ith] conventional free air thermal current: 200 A (at 60 °C) for power circuit
Irms rated making capacity: 1260 A at 440 V for power circuit conforming to IEC 60947
rated breaking capacity: 1100 A at 440 V for power circuit conforming to IEC 60947
[Icw] rated short-time withstand current: 250 A 40 °C - 10 min for power circuit; 550 A 40 °C - 1 min for power circuit; 950 A 40 °C - 10 s for power circuit; 1100 A 40 °C - 1 s for power circuit
associated fuse rating: 250 A gG at <= 690 V coordination type 1 for power circuit; 200 A gG at <= 690 V coordination type 2 for power circuit
average impedance: 0.6 mOhm - Ith 200 A 50 Hz for power circuit
[Ui] rated insulation voltage: Power circuit: 600 V CSA certified; Power circuit: 600 V UL certified; Power circuit: 1000 V conforming to IEC 60947-4-1
electrical durability: 0.8 Mcycles 200 A AC-1 at Ue <= 440 V
power dissipation per pole: 24 W AC-1
protective cover: With
interlocking type: Mechanical
mounting support: Plate; Rail
standards: CSA C22.2 No 14; EN 60947-4-1; EN 60947-5-1; IEC 60947-4-1; IEC 60947-5-1; UL 508
product certifications: BV; CCC; CSA; DNV; GL; RINA; UL; EAC; UKCA
connections - terminals: Control circuit: screw clamp terminals 2 cable(s) 1…2.5 mm²flexible with cable end; Control circuit: screw clamp terminals 1 cable(s) 1…2.5 mm²flexible without cable end; Control circuit: screw clamp terminals 2 cable(s) 1…2.5 mm²flexible without cable end; Control circuit: screw clamp terminals 1 cable(s) 1…2.5 mm²flexible with cable end; Control circuit: screw clamp terminals 1 cable(s) 1…2.5 mm²solid without cable end; Control circuit: screw clamp terminals 2 cable(s) 1…2.5 mm²solid without cable end; Power circuit: connector 1 cable(s) 10…120 mm²flexible without cable end; Power circuit: connector 2 cable(s) 10…50 mm²flexible without cable end; Power circuit: connector 1 cable(s) 10…120 mm²flexible with cable end; Power circuit: connector 2 cable(s) 10…50 mm²flexible with cable end; Power circuit: connector 1 cable(s) 10…120 mm²solid without cable end; Power circuit: connector 2 cable(s) 10…50 mm²solid without cable end
tightening torque: Control circuit: 1.2 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm; Control circuit: 1.2 N.m - on screw clamp terminals - with screwdriver Philips No 2; Power circuit: 12 N.m - on connector hexagonal screw head 4 mm
operating time: 20...50 ms closing; 6...20 ms opening
safety reliability level: B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1; B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
mechanical durability: 8000000 cycles
maximum operating rate: 2400 cyc/h 60 °C
Complementary
coil technology: Built-in bidirectional peak limiting diode suppressor
control circuit voltage limits: 0.3...0.5 Uc (-40…70 °C):drop-out AC 50/60 Hz; 0.8...1.15 Uc (-40…55 °C):operational AC 50/60 Hz; 1...1.15 Uc (55…70 °C):operational AC 50/60 Hz
inrush power in VA: 280…350 VA 60 Hz cos phi 0.8 (at 20 °C) ; 280…350 VA 50 Hz cos phi 0.8 (at 20 °C)
hold-in power consumption in VA: 2…18 VA (at 20 °C) cos phi 0.3 60 Hz; 2…18 VA (at 20 °C) cos phi 0.3 50 Hz
heat dissipation: 3…8 W at 50/60 Hz
contact compatibility: M14
compatibility code: LC2D
Environment
IP degree of protection: IP20 front face conforming to IEC 60529
protective treatment: TH conforming to IEC 60068-2-30
pollution degree: 3
ambient air temperature for operation: -40…60 °C; 60…70 °C with derating
ambient air temperature for storage: -60…80 °C
operating altitude: 0...3000 m
fire resistance: 850 °C conforming to IEC 60695-2-1
flame retardance: V1 conforming to UL 94
mechanical robustness: Vibrations contactor open: 2 Gn, 5...300 Hz; Vibrations contactor closed: 4 Gn, 5...300 Hz; Shocks contactor closed: 15 Gn for 11 ms; Shocks contactor open: 6 Gn for 11 ms
height: 158 mm
width: 334 mm
depth: 148 mm
net weight: 7.4 kg
Offer Sustainability
Sustainable offer status: Green Premium product
REACh Regulation: Free of Substances of Very High Concern above the threshold
EU RoHS Directive: Compliant
Mercury free: Yes
RoHS exemption information: Yes
China RoHS Regulation: Product out of China RoHS scope. Substance declaration for your information
Environmental Disclosure: ENVPEP060301EN
Circularity Profile: ENVEOLI100405EN
WEEE: The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
PVC free: Yes