Link to the manufacturers site: K50F006AP - cam switch - 6-pole - 60° - 50 A - screw mounting
Main
range of product: Harmony K
product or component type: Complete cam switch
component name: K50
[Ith] conventional free air thermal current: 50 A
product mounting: Front mounting
fixing mode: 4 holes
cam switch head type: With front plate 64 x 64 mm
type of operator: Black handle
rotary handle padlocking: Without
presentation of legend: With metallic legend, 0 - 1 black marking
cam switch function: Switch
return: Without
off position: With Off position
poles description: 6P
switching positions: Right: 0° - 60°
IP degree of protection: IP40 conforming to IEC 529; IP40 conforming to NF C 20-010
Complementary
switching angle: 60 °
[Ui] rated insulation voltage: 690 V (pollution degree 3) conforming to EN 60947-1; 690 V (pollution degree 3) conforming to IEC 60947-1
short-circuit current: 5000 A
short-circuit protection: 63 A cartridge fuse, type gG
[Uimp] rated impulse withstand voltage: 6 kV conforming to EN 947-1; 6 kV conforming to IEC 947-1
contact operation: Slow-break
positive opening: With
electrical connection: Captive screw clamp terminals flexible, clamping capacity: 2 x 6 mm²; Captive screw clamp terminals solid, clamping capacity: 2 x 10 mm²
tightening torque: 2 N.m
switching capacity in mA: 15000 mA DC at 120 V 2 contact(s) for inductive load (T = 50 ms); 15000 mA DC at 180 V 3 contact(s) for inductive load (T = 50 ms); 15000 mA DC at 60 V 1 contact(s) for inductive load (T = 50 ms); 20000 mA DC at 140 V 3 contact(s) for inductive load (T = 50 ms); 20000 mA DC at 48 V 1 contact(s) for inductive load (T = 50 ms); 20000 mA DC at 95 V 2 contact(s) for inductive load (T = 50 ms); 30000 mA DC at 30 V 1 contact(s) for inductive load (T = 50 ms); 30000 mA DC at 60 V 2 contact(s) for inductive load (T = 50 ms); 30000 mA DC at 90 V 3 contact(s) for inductive load (T = 50 ms); 3500 mA DC at 110 V 1 contact(s) for inductive load (T = 50 ms); 3500 mA DC at 220 V 2 contact(s) for inductive load (T = 50 ms); 3500 mA DC at 330 V 3 contact(s) for inductive load (T = 50 ms); 37000 mA DC at 120 V 2 contact(s) for resistive load (T = 1 ms); 37000 mA DC at 180 V 3 contact(s) for resistive load (T = 1 ms); 37000 mA DC at 60 V 1 contact(s) for resistive load (T = 1 ms); 40000 mA DC at 140 V 3 contact(s) for resistive load (T = 1 ms); 40000 mA DC at 24 V 1 contact(s) for inductive load (T = 50 ms); 40000 mA DC at 48 V 1 contact(s) for resistive load (T = 1 ms); 40000 mA DC at 48 V 2 contact(s) for inductive load (T = 50 ms); 40000 mA DC at 70 V 3 contact(s) for inductive load (T = 50 ms); 40000 mA DC at 95 V 2 contact(s) for resistive load (T = 1 ms); 50000 mA DC at 24 V 1 contact(s) for resistive load (T = 1 ms); 50000 mA DC at 48 V 2 contact(s) for resistive load (T = 1 ms); 50000 mA DC at 70 V 3 contact(s) for resistive load (T = 1 ms)
mechanical durability: 300000 cycles
CAD overall width: 64 mm
CAD overall height: 64 mm
CAD overall depth: 120 mm
net weight: 0.53 kg
compatibility code: K50F
Environment
standards: EN/IEC 60947-3
product certifications: CULus 120 V 3 hp 1 phase; CULus 480 V 25 hp 3 phases; CULus 240 V 7.5 hp 1 phase; CULus 240 V 7.5 hp 3 phases
protective treatment: TC
ambient air temperature for operation: -25…55 °C
ambient air temperature for storage: -40…70 °C
electrical shock protection class: Class II conforming to IEC 60536; Class II conforming to NF C 20-030
Offer Sustainability
REACh Regulation: Free of Substances of Very High Concern above the threshold
REACh free of SVHC: Yes
EU RoHS Directive: Pro-active compliance (Product out of EU RoHS legal scope)
Toxic heavy metal free: Yes
Mercury free: Yes
RoHS exemption information: Yes
China RoHS Regulation: X
WEEE: The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins