Schneider-Electric
K1D504A
Tariff code:
This product is discontinued.
Please contact us for possible replacement product options.
Link to the manufacturers site: K1D504A - body for switch - 4-pole - 45° - 12 A - rear mounting
Main
range of product: Harmony K
product or component type: Cam switch body
component name: K1
[Ith] conventional free air thermal current: 12 A
sub-assembly composition: Contact blocks + fixing plate
cam switch function: Switch
off position: With Off position
poles description: 4P
switching positions: Right: 0° - 45°
mounting location: Rear
fixing mode: 4 holes
bezel material: Plastic
Complementary
switching angle: 45 °
[Ui] rated insulation voltage: 690 V (pollution degree 3) conforming to IEC 60947-1
[Ithe] conventional enclosed thermal current: 10 A
rated operational power in W: 10500 W AC-21, 500 - 660 V 3 phases conforming to IEC 947-3; 1100 W AC-3, 230 V 3 phases conforming to IEC 947-3; 1500 W AC-23A, 230 V 3 phases conforming to IEC 947-3; 1500 W AC-3, 400 V 1 phase conforming to IEC 947-3; 1500 W AC-3, 400 V 3 phases conforming to IEC 947-3; 1500 W AC-3, 500 V 3 phases conforming to IEC 947-3; 1500 W AC-3, 690 V 3 phases conforming to IEC 947-3; 2200 W AC-23A, 400 V 3 phases conforming to IEC 947-3; 2200 W AC-23A, 500 V 3 phases conforming to IEC 947-3; 2200 W AC-23A, 690 V 3 phases conforming to IEC 947-3; 4800 W AC-21, 230 V 3 phases conforming to IEC 947-3; 600 W AC-3, 230 V 1 phase conforming to IEC 947-3; 8300 W AC-21, 400 V 3 phases conforming to IEC 947-3
[Ie] rated operational current AC: 1.8 A at 690 V AC-3 3 phases conforming to IEC 947-3; 2.8 A at 500 V AC-3 3 phases conforming to IEC 947-3; 2.8 A at 690 V AC-23A 3 phases conforming to IEC 947-3; 3.3 A at 400 V AC-3 3 phases conforming to IEC 947-3; 3.8 A at 500 V AC-23A 3 phases conforming to IEC 947-3; 4.6 A at 230 V AC-3 3 phases conforming to IEC 947-3; 4.8 A at 400 V AC-23A 3 phases conforming to IEC 947-3; 5.6 A at 230 V AC-23A 3 phases conforming to IEC 947-3; 1 A at 500 V AC-15 conforming to IEC 947-5-1; 2 A at 400 V AC-15 conforming to IEC 947-5-1; 3 A at 230 V AC-15 conforming to IEC 947-5-1
electrical durability: 1000000 cycles AC-15; 1000000 cycles AC-21; 500000 cycles AC-23; 500000 cycles AC-3
maximum operating rate: 2.5 cyc/mn AC-21; 2.5 cyc/mn AC-23; 2.5 cyc/mn AC-3; 8.333 cyc/mn AC-15
short-circuit current: 10000 A
short-circuit protection: 16 A cartridge fuse, type gG
[Uimp] rated impulse withstand voltage: 4 kV in isolating function; 6 kV conforming to IEC 947-1
contact operation: Slow-break
positive opening: With
electrical connection: Captive screw clamp terminals flexible, clamping capacity: 2 x 1.5 mm²; Captive screw clamp terminals solid, clamping capacity: 1 x 2.5 mm²
mechanical durability: 1000000 cycles
net weight: 0.15 kg
compatibility code: K1D
Environment
standards: EN 60947-3 for power circuit; EN 60947-5-1 for control circuit; IEC 60947-3 for power circuit; IEC 60947-5-1 for control circuit; CENELEC EN 50013
product certifications: CSA 240 V 3 hp 3 phases 2 -pole(s); UL 240 V 0.33 hp 1 phase 2 -pole(s); CSA 240 V 1 hp 1 phase; UL 240 V 1 hp 3 phases
protective treatment: TC
ambient air temperature for operation: -25…55 °C
ambient air temperature for storage: -40…70 °C
shock resistance: 30 gn conforming to IEC 68-2-27
vibration resistance: 5 gn conforming to IEC 68-2-6 (f = 10…150 Hz)
overvoltage category: Class II conforming to IEC 536; Class II conforming to NF C 20-030
Offer Sustainability
Sustainable offer status: Green Premium product
REACh Regulation: Free of Substances of Very High Concern above the threshold
REACh free of SVHC: Yes
EU RoHS Directive: Pro-active compliance (Product out of EU RoHS legal scope)
Toxic heavy metal free: Yes
Mercury free: Yes
RoHS exemption information: Yes
China RoHS Regulation: X
Environmental Disclosure: ENVPEP071103EN_V1
WEEE: The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
© 2018 Alplan Kft.