5”7 color touch controller panel - Dig 8 inputs/8 outputs +Ana 4 In/2 Out
Net discounted price 1,007.63 EUR
Available when ordered (delivery time: 61 working day(s))
Barcode: 3595864175584
Tariff code: 8537101090

Link to the manufacturers site: HMISCU8B5 - 5”7 color touch controller panel - Dig 8 inputs/8 outputs +Ana 4 In/2 Out

Main

Range of produc: Harmony SCU

Product or component type: Small touch HMI controller

Display size: 5.7 inch

Display type: with backlit LED colour TFT LCD

Touch panel: Analogue

device presentation: Complete product

Complementary

Display resolution: 320 x 240 pixels QVGA

Backlight lifespan: 50000 hours with 65000 colours

Brightness: 16 levels via touch panel

View angle horiz x vert: 60° left; 60° right; 40° top; 60° bottom

character font: Chinese (simplified Chinese); Japanese (ANK, Kanji); ASCII; Korean; Taiwanese (traditional Chinese)

supply: External source

[Us] rated supply voltage: 24 V (20.4…28.8 V)DC

Immunity to microbreaks: 10 ms

Inrush current: 30 A

Power consumption in W: 24 W

local signalling: No indicator

Number of pages: Limited by internal memory capacity

Software designation: SoMachine

Operating system: Harmony

Processor name: CPU RISC

Processor frequency: 333 MHz

Memory description: Flash NAND, 128 MB; Internal data storage FRAM, 128 kB; Application run DRAM, 128 MB

Integrated connection type: 1 serial link - RJ45 - RS232/RS485 (rate: <= 115.2 kbits/s); 1 Ethernet TCP/IP - RJ45; 1 USB 2.0 type mini B; 1 USB 2.0 type A; CANopen master bus - SUB-D 9

Realtime clock: Built-in

Downloadable protocols: Modbus; Modbus TCP/IP; CANopen

Fixing mode: By 1 nut - diameter: Ø 22 mm, mounting on: 1...6 mm thick panel

Enclosure material: PC/PBT and PAA

Shock resistance: 147 m/s² for 11 ms (on DIN rail) conforming to IEC 60068-2-27; 294 m/s² for 6 ms (on panel mounting) conforming to IEC 60068-2-27

Vibration resistance: +/- 3.5 mm (f = 5…9 Hz) conforming to IEC 60068-2-6; 1 gn (f = 9…150 Hz) conforming to IEC 60068-2-6

Electromagnetic compatibility: Electrostatic discharge immunity test - test level: 8 kV (air discharge) conforming to IEC 61000-4-2; Electrostatic discharge immunity test - test level: 6 kV (contact discharge) conforming to IEC 61000-4-2; Susceptibility to electromagnetic fields - test level: 10 V/m (80 MHz...3 GHz) conforming to IEC 61000-4-3; Electrical fast transient/burst immunity test - test level: 2 kV (power lines) conforming to IEC 61000-4-4; Electrical fast transient/burst immunity test - test level: 1 kV (between analogue I/O and operating voltage) conforming to IEC 61000-4-4; Electrical fast transient/burst immunity test - test level: 2 kV (relay wires) conforming to IEC 61000-4-4; Electrical fast transient/burst immunity test - test level: 1 kV (Ethernet line) conforming to IEC 61000-4-4; Electrical fast transient/burst immunity test - test level: 1 kV (COM line) conforming to IEC 61000-4-4; Electrical fast transient/burst immunity test - test level: 1 kV (CAN line) conforming to IEC 61000-4-4; Surge immunity test - test level: 2 kV (power supply (common mode)) conforming to IEC 61000-4-5; Surge immunity test - test level: 1 kV (power supply (differential mode)) conforming to IEC 61000-4-5; Surge immunity test - test level: 1 kV common mode (digital I/O) conforming to IEC 61000-4-5; Surge immunity test - test level: 0.5 kV differential mode (digital I/O) conforming to IEC 61000-4-5; Conducted RF disturbances - test level: 10 V (0.15...80 MHz) conforming to IEC 61000-4-6; Conducted emission - test level: 150 kHz...30 MHz conforming to EN 55011; Radiated emission - test level: 30 MHz...1 GHz conforming to EN 55011

Discrete input number: 2 for fast input (normal mode) conforming to IEC 61131-2 Type 1; 6 for digital input conforming to IEC 61131-2 Type 1

Discrete input voltage: 24 V DC, discrete input logic: sink or source (positive/negative)

Number of common point: 1 for fast input (HSC mode); 1 for digital input

Discrete input current: 7.83 mA for fast input; 5 mA for digital

Input impedance: 4.7 kOhm; 2.81 kOhm

Sensor power supply: 15…28.8 V DC >= 15 V, current (state 1): >= 5 mA <= 5 V, current (state 0): <= 1.5 mA; 15…28.8 V DC >= 15 V, current (state 1): >= 2.5 mA <= 5 V, current (state 0): <= 1 mA

Configurable filtering time: 0 ms no filter (none); 0.004...0.04 ms bounce filter (latch/event and cumulative filter by step Nx0.5ms (64>=N>=2)); 3...12 ms integrator (none/run/stop)

Maximum input frequency: 100 kHz for fast input (encoder mode) - control type A/B; 100 kHz for fast input - control type single phase; 100 kHz for fast input - control type pulse/direction

Maximum cable distance between devices: Shielded cable: <10 m for fast input; Shielded cable: <100 m for digital input; Unshielded cable: <50 m for digital input

Connection pitch: 3.5 mm

Overvoltage protection: With overvoltage protection

Isolation between channels and internal logic: 500 V DC

Isolation between channels: None

Discrete output number: 2 fast output (normal mode), output logic: source; 6 digital output, output logic: source

Discrete output voltage: 24 V DC (voltage limit: 19.2...28.8 V) with transistor discrete output(s); 24 V DC (voltage limit: 5...30 V) with relay discrete output(s); 220 V AC (voltage limit: 100...250 V) with relay discrete output(s)

Input/output number: 2 for fast input, terminal(s): FI0...FI1; 2 for fast output, terminal(s): FQ0...FQ1; 6 for digital input, terminal(s): DI0...DI5; 6 for digital output, terminal(s): DQ0...DQ5

Discrete output current: 2 A 4 A), response time 5 ms with opening contact for digital output; 2 A 4 A), response time 2 ms with closing contact for digital output; 300 mA, response time 2 ms for fast output (normal mode); 50 mA, response time 2 ms for fast output (PWM or PTO mode)

Insulation resistance: > 10 MOhm between the I/O and internal logic; > 10 MOhm between power supply and earth

Maximum output frequency: 100 kHz for fast output (PTO mode); 1 kHz for fast output (PWM mode)

Absolute accuracy error: +/- 0.1 % of full scale cyclic ratio 1...99% for fast output (PWM or PTO mode); 1 % of full scale cyclic ratio 1...99% for fast output (PWM or PTO mode); +/- 5 % of full scale cyclic ratio 10...90% for fast output (PWM or PTO mode); +/- 10 % of full scale cyclic ratio 20...80% for fast output (PWM or PTO mode); +/- 15 % of full scale cyclic ratio 30...70% for fast output (PWM or PTO mode)

Analogue input number: 2 for analog input; 2 for RTDs

Analogue input range: 0...20 mA/4...20 mA - resolution: 12 bits, input impedance: 250 Ohm (tolerance: +/- 1 %); -10...+10 V or 0...10 V - resolution: 12 bits + sign, input impedance: >= 1 MOhm

Analogue input type: RTD at - 200...600 °C - resolution: 16 bits temperature probe: Pt 100/Pt 1000; RTD at - 50...200 °C - resolution: 16 bits temperature probe: Ni 100/Ni 1000; RTD at - 200...760 °C - resolution: 16 bits (thermocouple J); RTD at - 240...1370 °C - resolution: 16 bits (thermocouple K); RTD at 0...1600 °C - resolution: 16 bits (thermocouple R); RTD at 200...1800 °C - resolution: 16 bits (thermocouple B); RTD at 0...1600 °C - resolution: 16 bits (thermocouple S); RTD at - 200...400 °C - resolution: 16 bits (thermocouple T); RTD at - 200...900 °C - resolution: 16 bits (thermocouple E); RTD at - 200...1300 °C - resolution: 16 bits (thermocouple N)

Analogue output number: 2 resistive load for 12 bits + sign

Analogue output range: 0...20 mA/4...20 mA (> 300 Ohm) for open-circuit; -10...10 V/0...10 V (> 2 kOhm) for short-circuit

height: 129.4 mm

Width: 163 mm

Depth: 76.22 mm

Net weight: 0.803 kg

Environment

Standards: FCC Class A; EN 61131-2; UL 508; IEC 61000-6-2; CSA C22.2 No 213 Class I Division 2; ANSI/ISA 12-12-01

product certifications: cULus 508; cULus CSA 22-2 No 142; GOST; cUL 1604 Class 1 Division 2; C-Tick; KCC; UKCA; UKEX

Marking: CE

ambient air temperature for operation: 0…50 °C

Ambient air temperature for storage: -20…60 °C

Relative humidity: 5…85 % without condensation

Operating altitude: <= 2000 m

Storage altitude: 0…10000 m

Maximum pressure: 800...1114 hPa

IP degree of protection: IP20 (rear panel) conforming to IEC 60529; IP65 (front panel) conforming to IEC 60529

NEMA degree of protection: NEMA 4X front panel

Pollution degree: 2 conforming to IEC 60664

Environmental characteristic: Corrosive gas free

Packing Units

Unit Type of Package 1: PCE

Number of Units in Package 1: 1

Package 1 Height: 18.8 cm

Package 1 Width: 11 cm

Package 1 Length: 20.7 cm

Package 1 Weight: 1.364 kg

Unit Type of Package 2: S03

Number of Units in Package 2: 4

Package 2 Height: 30 cm

Package 2 Width: 30 cm

Package 2 Length: 40 cm

Package 2 Weight: 5.964 kg

Unit Type of Package 3: P12

Number of Units in Package 3: 64

Package 3 Height: 75 cm

Package 3 Width: 80 cm

Package 3 Length: 120 cm

Package 3 Weight: 135.776 kg

Offer Sustainability

REACh Regulation: Reference contains Substances of Very High Concern above the threshold

EU RoHS Directive: Pro-active compliance (Product out of EU RoHS legal scope)

Mercury free: Yes

China RoHS Regulation: X

RoHS exemption information: Yes

WEEE: The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins

Upgradeability: Upgradeable through digital modules and upgraded components