Skip to main content

Schneider-Electric
GV3P406

Motor circuit breaker, TeSys GV3, 3P, 30-40 A, thermal magnetic, lugs terminals
Barcode: 3389118204119
Tariff code:

This product is discontinued.

Please contact us for possible replacement product options.

Link to the manufacturers site: GV3P406 - Motor circuit breaker, TeSys GV3, 3P, 30-40 A, thermal magnetic, lugs terminals

Main

range: TeSys; TeSys Deca

range of product: TeSys GV3

product name: TeSys GV3; TeSys Deca

product or component type: Circuit breaker

device short name: GV3P

device application: Motor

trip unit technology: Thermal-magnetic

Complementary

poles description: 3P

network type: AC

utilisation category: AC-3 conforming to IEC 60947-4-1; Category A conforming to IEC 60947-2

network frequency: 50/60 Hz conforming to IEC 60947-4-1

fixing mode: 35 mm symmetrical DIN rail: clipped; Panel: screwed (with 3 x M4 screws)

operating position: Any position

motor power kW: 18.5 kW at 400/415 V AC 50/60 Hz; 22 kW at 500 V AC 50/60 Hz; 37 kW at 690 V AC 50/60 Hz

breaking capacity: 100 kA Icu at 230/240 V AC 50/60 Hz conforming to IEC 60947-2; 50 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2; 6 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2; 50 kA Icu at 400/415 V AC 50/60 Hz conforming to IEC 60947-2; 12 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2

[Ics] rated service short-circuit breaking capacity: 100 % at 230/240 V AC 50/60 Hz conforming to IEC 60947-2; 100 % at 440 V AC 50/60 Hz conforming to IEC 60947-2; 100 % at 400/415 V AC 50/60 Hz conforming to IEC 60947-2; 50 % at 500 V AC 50/60 Hz conforming to IEC 60947-2; 50 % at 690 V AC 50/60 Hz conforming to IEC 60947-2

control type: Rotary knob

[In] rated current: 40 A

trip unit rating: 30…40 A

magnetic tripping current: 560 A

[Ue] rated operational voltage: 690 V AC 50/60 Hz conforming to IEC 60947-2

[Ui] rated insulation voltage: 690 V AC 50/60 Hz conforming to IEC 60947-2

[Ith] conventional free air thermal current: 40 A conforming to IEC 60947-4-1

[Uimp] rated impulse withstand voltage: 6 kV conforming to IEC 60947-2

power dissipation per pole: 8 W

mechanical durability: 50000 cycles

electrical durability: 50000 cycles for AC-3 at 440 V In

maximum operating rate: 25 cyc/h

rated duty: Continuous conforming to IEC 60947-4-1

connection pitch: 17.5 mm without spreaders

direct connector: Without

tightening torque: 6 N.m on bars M6 screw type ; 6 N.m on lugs-ring terminals M6 screw type

suitability for isolation: Yes conforming to IEC 60947-1

phase failure sensitivity: Yes conforming to IEC 60947-4-1

height: 132 mm

width: 55 mm

depth: 136 mm

net weight: 0.96 kg

colour: Dark grey

compatibility code: GV3P

Environment

standards: EN/IEC 60947-2; EN/IEC 60947-4-1; CSA C22.2 No 60947-4-1; UL 60947-4-1

product certifications: IECEE CB Scheme; UL; CSA; CCC; EAC; ATEX; BV; LROS (Lloyds register of shipping); DNV-GL; ABS; UKCA

protective treatment: TH

IP degree of protection: IP20 conforming to IEC 60529

IK degree of protection: IK09

ambient air temperature for operation: -20…60 °C

ambient air temperature for storage: -40…80 °C

fire resistance: 960 °C conforming to IEC 60695-2-1

operating altitude: 3000 m

Offer Sustainability

Sustainable offer status: Green Premium product

REACh Regulation: Reference contains Substances of Very High Concern above the threshold

EU RoHS Directive: Compliant

Mercury free: Yes

RoHS exemption information: Yes

China RoHS Regulation: Product out of China RoHS scope. Substance declaration for your information

Environmental Disclosure: ENVPEP060901EN

WEEE: The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins

© 2018 Alplan Kft.