Schneider-Electric
ATV71LD33N4Z
Tariff code: 8504409590
Link to the manufacturers site: ATV71LD33N4Z - ATVLIFT 480V 33A 15KW W O GRAPHIC TERM V
Main
Device short name: ATV71
Product destination: Asynchronous motors; Synchronous motors
Network number of phases: 3 phases
Supply voltage limits: 323…528 V
Supply frequency: 50...60 Hz - 5...5 %
Motor power kW: 15 kW, 3 phases at 380...480 V
Motor power hp: 20 hp, 3 phases at 380...480 V
Line current: 48 A for 380 V 3 phases 15 kW / 20 hp; 39 A for 480 V 3 phases 15 kW / 20 hp
Range of produc: Altivar Lift
Product or component type: Variable speed drive
Product specific application: Lift
variant: With integrated 7-segment display terminal
communication port protocol: Modbus; CANopen
[Us] rated supply voltage: 380...480 V - 15...10 %
EMC filter: Integrated
Complementary
Apparent power: 31.6 kVA at 380 V 3 phases 15 kW / 20 hp
Prospective line Isc: 22 kA for 3 phases
Nominal output current: 33 A at 4 kHz 380 V 3 phases 15 kW / 20 hp; 27 A at 4 kHz 460 V 3 phases 15 kW / 20 hp
Maximum transient current: 44.9 A for 2 s 3 phases / 15 kW / 20 hp
Speed drive output frequency: 0…599 Hz
Speed range: 1…100 for asynchronous motor in open-loop mode, without speed feedback; 1…50 for synchronous motor in open-loop mode, without speed feedback; 1…1000 for asynchronous motor in closed-loop mode with encoder feedback
Torque accuracy: +/- 5 % in closed-loop mode with encoder feedback; +/- 15 % in open-loop mode, without speed feedback
Transient overtorque: 170 %, +/- 10 % for 60 s; 220 %, +/- 10 % for 2 s
Braking torque: 30 % without braking resistor; <= 150 % with braking or hoist resistor
Local signalling: 1 LED (red) for drive voltage
Output voltage: <= power supply voltage
insulation: Electrical between power and control
Type of cable: Without mounting kit: 1 wire(s)IEC cable at 45 °C, copper 90 °C / XLPE/EPR; Without mounting kit: 1 wire(s)IEC cable at 45 °C, copper 70 °C / PVC; With an IP21 or an IP31 kit: 3 wire(s)IEC cable at 40 °C, copper 70 °C / PVC; With a NEMA Type1 kit: 3 wire(s)UL 508 cable at 40 °C, copper 75 °C / PVC
Electrical connection: Terminal, clamping capacity: 2.5 mm², AWG 14 (AI1-/AI1+, AI2, AO1, R1A, R1B, R1C, R2A, R2B, LI1...LI6, PWR); Terminal, clamping capacity: 35 mm², AWG 2 (L1/R, L2/S, L3/T, U/T1, V/T2, W/T3, PC/-, PO, PA/+, PA, PB)
Tightening torque: 5.4 N.m, 47.7 lb.in (L1/R, L2/S, L3/T, U/T1, V/T2, W/T3, PC/-, PO, PA/+, PA, PB); 0.6 N.m (AI1-/AI1+, AI2, AO1, R1A, R1B, R1C, R2A, R2B, LI1...LI6, PWR)
Supply: Internal supply for reference potentiometer (1 to 10 kOhm): 10.5 V DC +/- 5 %, <10 A, protection type: overload and short-circuit protection; Internal supply: 24 V DC (21…27 V), <200 A, protection type: overload and short-circuit protection
Sampling duration: 2 ms +/- 0.5 ms (LI6)if configured as logic input - discrete input(s); 2 ms +/- 0.5 ms (LI1...LI5) - discrete input(s); 2 ms +/- 0.5 ms (AI1-/Al1+) - analog input(s); 2 ms +/- 0.5 ms (Al2) - analog input(s)
Response time: R1A, R1B, R1C 7 ms, tolerance +/- 0.5 ms for discrete output(s); R2A, R2B 7 ms, tolerance +/- 0.5 ms for discrete output(s); AO1 2 ms, tolerance +/- 0.5 ms for analog output(s); <= 100 ms in STO (Safe Torque Off)
Accuracy: +/- 0.6 % (AI1-/Al1+) for a temperature variation 60 °C; +/- 0.6 % (AI2) for a temperature variation 60 °C; +/- 1 % (AO1) for a temperature variation 60 °C
Linearity error: +/- 0.15 % of maximum value (AI1-/Al1+, AI2); +/- 0.2 % (AO1)
Analogue output type: AO1 software-configurable voltage: 0...10 V DC, impedance: 470 Ohm, resolution 10 bits; AO1 software-configurable current: 0...20 mA, impedance: 500 Ohm, resolution 10 bits; AO1 software-configurable logic output 10 V 20 A
Discrete output type: Configurable relay logic: (R1A, R1B, R1C) NO/NC - 100000 cycles; Configurable relay logic: (R2A, R2B) NO - 100000 cycles
Minimum switching current: 3 mA at 24 V DC for configurable relay logic
Maximum switching current: 5 A at 250 V AC on resistive load - cos phi = 1 - L/R = 0 ms (R1, R2); 5 A at 30 V DC on resistive load - cos phi = 1 - L/R = 0 ms (R1, R2); 2 A at 250 V AC on inductive load - cos phi = 0.4 - L/R = 7 ms (R1, R2); 2 A at 30 V DC on inductive load - cos phi = 0.4 - L/R = 7 ms (R1, R2)
Discrete input type: Programmable (LI1...LI5)24 V DC, with level 1 PLC - 3500 Ohm; Switch-configurable (LI6)24 V DC, with level 1 PLC - 3500 Ohm; Switch-configurable PTC probe (LI6) - 0…6 probes - 1500 Ohm; Safety input (PWR)24 V DC - 1500 Ohm
Discrete input logic: Positive logic (LI6)if configured as logic input, < 5 V (state 0), > 11 V (state 1); Negative logic (LI6)if configured as logic input, > 16 V (state 0), < 10 V (state 1); Positive logic (LI1...LI5), < 5 V (state 0), > 11 V (state 1); Negative logic (LI1...LI5), > 16 V (state 0), < 10 V (state 1); Positive logic (PWR), < 2 V (state 0), > 17 V (state 1)
Dielectric strength: 3535 V DC between earth and power terminals; 5092 V DC between control and power terminals
Insulation resistance: > 1 mOhm 500 V DC for 1 minute to earth
Frequency resolution: Display unit: 0.1 Hz; Analog input: 0.024/50 Hz
Connector type: 1 RJ45 (on front face) for Modbus; 1 RJ45 (on terminal) for Modbus; Male SUB-D 9 on RJ45 for CANopen
Physical interface: 2-wire RS 485 for Modbus
Transmission frame: RTU for Modbus
Transmission rate: 9600 bps, 19200 bps for Modbus on front face; 4800 bps, 9600 bps, 19200 bps, 38.4 Kbps for Modbus on terminal; 20 kbps, 50 kbps, 125 kbps, 250 kbps, 500 kbps, 1 Mbps for CANopen
Data format: 8 bits, 1 stop, even parity for Modbus on front face; 8 bits, odd even or no configurable parity for Modbus on terminal
Type of polarization: No impedance for Modbus
Number of addresses: 1…247 for Modbus; 1…127 for CANopen
Option card: Communication card for Modbus TCP; Communication card for Fipio; Communication card for Modbus/Uni-Telway; Communication card for Modbus Plus; Communication card for EtherNet/IP; Communication card for DeviceNet; Communication card for Profibus DP; Communication card for Profibus DP V1; Communication card for Interbus-S; Communication card for CC-Link; Interface card for encoder; I/O extension card; Controller inside programmable card; Overhead crane card
Discrete input number: 7
Discrete output number: 2
analogue input number: 2
Analogue input type: AI2 software-configurable voltage: 0...10 V DC 24 V max, impedance: 30000 Ohm, resolution 11 bits; AI1-/Al1+ bipolar differential voltage: +/- 10 V DC 24 V max, resolution 11 bits + sign; AI2 software-configurable current: 0...20 mA, impedance: 242 Ohm, resolution 11 bits
analogue output number: 1
Method of access: Slave CANopen
Asynchronous motor control profile: Voltage/frequency ratio - Energy Saving, quadratic U/f; Flux vector control without sensor, standard; Flux vector control without sensor, ENA (energy Adaptation) system; Voltage/frequency ratio, 5 points; Flux vector control with sensor, standard; Voltage/frequency ratio, 2 points; Flux vector control without sensor, 2 points
Synchronous motor control profile: Vector control without sensor, standard; Vector control with sensor, standard
Acceleration and deceleration ramps: S, U or customized; Linear adjustable separately from 0.01 to 9000 s; Automatic adaptation of ramp if braking capacity exceeded, by using resistor
Motor slip compensation: Automatic whatever the load; Not available in voltage/frequency ratio (2 or 5 points); Suppressable; Adjustable
Switching frequency: 1...16 kHz adjustable
Nominal switching frequency: 8 kHz
Minimum braking resistance: 7 Ohm
Network frequency: 47.5...63 Hz
Protection type: Overheating protection: drive; Thermal protection: drive; Short-circuit between motor phases: drive; Input phase breaks: drive; Overcurrent between output phases and earth: drive; Overvoltages on the DC bus: drive; Break on the control circuit: drive; Against exceeding limit speed: drive; Line supply undervoltage: drive; Line supply overvoltage: drive; Against input phase loss: drive; Thermal protection: motor; Motor phase break: motor; Power removal: motor
Environment
Pollution degree: 2 conforming to IEC 61800-5-1
IP degree of protection: IP20 on upper part without blanking plate on cover conforming to IEC 61800-5-1; IP20 on upper part without blanking plate on cover conforming to IEC 60529; IP21 conforming to IEC 61800-5-1; IP21 conforming to IEC 60529; IP41 on upper part conforming to IEC 61800-5-1; IP41 on upper part conforming to IEC 60529; IP54 on lower part conforming to IEC 61800-5-1; IP54 on lower part conforming to IEC 60529
Vibration resistance: 1.5 mm peak to peak (f= 3…13 Hz) conforming to IEC 60068-2-6; 1 gn (f= 13…200 Hz) conforming to IEC 60068-2-6
Shock resistance: 15 gn for 11 ms conforming to IEC 60068-2-27
Noise level: 60.2 dB conforming to 86/188/EEC
Relative humidity: 5…95 % without condensation conforming to IEC 60068-2-3; 5…95 % without dripping water conforming to IEC 60068-2-3
Ambient air temperature for operation: -10…50 °C (without derating)
Operating altitude: <= 1000 m without derating; 1000...3000 m with current derating 1 % per 100 m
Operating position: Vertical +/- 10 degree
product certifications: C-Tick; CSA; GOST; UL; NOM 117
Marking: CE
Standards: EN 55011 class A group 2; IEC 61800-3 environments 1 category C3; IEC 61800-5-1; IEC 61800-3 environments 2 category C3; IEC 60721-3-3 class 3C1; UL Type 1; IEC 60721-3-3 class 3S2; IEC 61800-3
Assembly style: With heat sink
Electromagnetic compatibility: Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2; Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3; Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4; 1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5; Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6; Voltage dips and interruptions immunity test conforming to IEC 61000-4-11
Regulation loop: Adjustable PI regulator
Speed accuracy: +/- 0.01 % of nominal speed in closed-loop mode with encoder feedback 0.2 Tn to Tn; +/- 10 % of nominal slip without speed feedback 0.2 Tn to Tn
Ambient air temperature for storage: -25…70 °C
Packing Units
Unit Type of Package 1: PCE
Number of Units in Package 1: 1
Package 1 Height: 35.000 cm
Package 1 Width: 60.000 cm
Package 1 Length: 40.000 cm
Package 1 Weight: 17.391 kg
Unit Type of Package 2: P06
Number of Units in Package 2: 2
Package 2 Height: 75.000 cm
Package 2 Width: 60.000 cm
Package 2 Length: 80.000 cm
Package 2 Weight: 43.282 kg
Offer Sustainability
REACh Regulation: Reference contains Substances of Very High Concern above the threshold
EU RoHS Directive: Pro-active compliance (Product out of EU RoHS legal scope)
Mercury free: Yes
China RoHS Regulation: X
RoHS exemption information: Yes
WEEE: The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
© 2018 Alplan Kft.