Schneider-Electric
ATV12P055M2
Tariff code: 8504409590
Link to the manufacturers site: ATV12P055M2 - variable speed drive ATV12 - 0.55 kW - 0.75hp - 200..240V - 1ph - on base plate
Main
Range of produc: Altivar 12
Product or component type: Variable speed drive
Product specific application: Simple machine
Design of frequency changer: U converter
Mounting mode: Cabinet mount
communication port protocol: Modbus
Supply frequency: 50/60 Hz +/- 5 %
[Us] rated supply voltage: 200...240 V - 15...10 %
[Us] rated supply voltage: 200...240 V
Relative symmetric mains voltage tolerance: 10 %
Nominal output current: 3.5 A
Number of input phases: 3
Number of output phases: 3
Motor power kW: 0.55 kW
Motor power hp: 0.75 hp
EMC filter: Integrated
IP degree of protection: IP20
Complementary
Discrete input number: 4
Discrete output number: 2
analogue input number: 1
analogue output number: 1
Relay output number: 1
Number of inputs, bidirectional, not potential-free: 0
Number of inputs, potential-free: 0
Computer port: True
Optical interface present: False
Physical interface: 2-wire RS 485
Connector type: 1 RJ45
Continuous output current: 3.5 A at 4 kHz
Method of access: Server Modbus serial
Speed drive output frequency: 0.5…400 Hz
Speed range: 1…20
Sampling duration: 20 ms, tolerance +/- 1 ms for logic input; 10 ms for analogue input
Linearity error: +/- 0.3 % of maximum value for analogue input
Frequency resolution: Analog input: converter A/D, 10 bits; Display unit: 0.1 Hz
Time constant: 20 ms +/- 1 ms for reference change
Transmission rate: 9.6 kbit/s; 19.2 kbit/s; 38.4 kbit/s
Transmission frame: RTU
Number of addresses: 1…247
Data format: 8 bits, configurable odd, even or no parity
Communication service: Read holding registers (03) 29 words; Write single register (06) 29 words; Write multiple registers (16) 27 words; Read/write multiple registers (23) 4/4 words; Read device identification (43)
Type of polarization: No impedance
Number of HW interfaces parallel: 0
Number of HW interfaces industrial Ethernet: 0
Number of HW interfaces PROFINET: 0
Number of HW interfaces serial RS232: 0
Number of HW interfaces serial RS422: 0
Number of HW interfaces serial RS485: 1
Number of HW interfaces serial TTY: 0
Number of HW interfaces USB: 0
Number of HW interfaces other: 0
Supporting protocol for AS-Interface Safety at Work: False
Supporting protocol for ASI: False
Supporting protocol for SUCONET: False
Supporting protocol for BACnet: False
Supporting protocol for CAN: False
Supporting protocol for Data-Highway: False
Supporting protocol for DeviceNet: False
Supporting protocol for DeviceNet Safety: False
Supporting protocol for EtherNet/IP: False
Supporting protocol for Foundation Fieldbus: False
Supporting protocol for INTERBUS: False
Supporting protocol for INTERBUS-Safety: False
Supporting protocol for KNX: False
Supporting protocol for LON: False
Supporting protocol for MODBUS: True
Supporting protocol for other bus systems: False
Supporting protocol for PROFIBUS: False
Supporting protocol for PROFINET CBA: False
Supporting protocol for PROFINET IO: False
Supporting protocol for PROFIsafe: False
Supporting protocol for SafetyBUS P: False
Supporting protocol for SERCOS: False
Supporting protocol for TCP/IP: False
4 quadrant operation possible: False
Asynchronous motor control profile: Voltage/frequency ratio (V/f); Sensorless flux vector control; Quadratic voltage/frequency ratio
maximum output frequency: 4 kHz
Transient overtorque: 150…170 % of nominal motor torque depending on drive rating and type of motor
Acceleration and deceleration ramps: Linear from 0 to 999.9 s; S; U
Motor slip compensation: Preset in factory; Adjustable
Switching frequency: 2...16 kHz adjustable; 4...16 kHz with derating factor
Nominal switching frequency: 4 kHz
Braking to standstill: By DC injection
Brake chopper integrated: False
Maximum associated fuse rating: 12.5 A
Line current: 8.0 A at 100 V (heavy duty); 6.7 A at 120 V (heavy duty)
Maximum input current: 6.7 A
Maximum output voltage: 240 V
Nominal output power: 550.0 W
Apparent power: 1.6 kVA at 240 V (heavy duty)
Maximum transient current: 5.3 A during 60 s (heavy duty); 5.8 A during 2 s (heavy duty)
Capacity of DC link: 780.0 µF
Network frequency: 50...60 Hz
Relative symmetric network frequency tolerance: 5 %
Prospective line Isc: 1 kA
1 phase low current possible: False
Base load current at high overload: 3.5 A
Application in domestic and commercial area permitted: False
Application in industrial area permitted: True
EMC limit value (complied): True
Power loss per device current dependent: 34.0 W
Power loss static current independent: 8.0 W
Power dissipation in W: Natural: 34.0 W
Housing material: Plastic
With safety function Safely Limited Speed (SLS): False
With safety function Safe brake management (SBC/SBT): False
With safety function Safe Operating Stop (SOS): False
With safety function Safe Position (SP): False
With safety function Safe programmable logic: False
With safety function Safe Speed Monitor (SSM): False
With safety function Safe Stop 1 (SS1): False
With sft fct Safe Stop 2 (SS2): False
With safety function Safe torque off (STO): False
With safety function Safely Limited Position (SLP): False
With safety function Safe Direction (SDI): False
Protection type: Line supply overvoltage; Line supply undervoltage; Overcurrent between output phases and earth; Overheating protection; Short-circuit between motor phases; Against input phase loss in three-phase; Thermal motor protection via the drive by continuous calculation of I²t
Operating element present: True
Tightening torque: 0.8 N.m
insulation: Electrical between power and control
Quantity per set: Set of 1
Width: 72 mm
height: 143 mm
Depth: 102.2 mm
Net weight: 0.7 kg
Environment
Operating altitude: > 1000...2000 m with current derating 1 % per 100 m; <= 1000 m without derating
Operating position: Vertical +/- 10 degree
product certifications: NOM; CSA; C-Tick; UL; GOST; RCM; KC
Marking: CE
Standards: UL 508C; UL 618000-5-1; IEC 61800-5-1; IEC 61800-3
Assembly style: On base plate
Electromagnetic compatibility: Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4; Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2; Immunity to conducted disturbances level 3 conforming to IEC 61000-4-6; Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3; Surge immunity test level 3 conforming to IEC 61000-4-5; Voltage dips and interruptions immunity test conforming to IEC 61000-4-11
Environmental class (during operation): Class 3C3 according to IEC 60721-3-3; Class 3S2 according to IEC 60721-3-3
Environmental class (during storage): Class 1C3 according to IEC 60721-3-1; Class 1S2 according to IEC 60721-3-1
Environmental class (during transport): Class 2C3 according to IEC 60721-3-2; Class 2S1 according to IEC 60721-3-2
Maximum acceleration under shock impact (during operation): 150 m/s² at 11 ms
Maximum acceleration under shock load (during storage): 150 m/s² at 11 ms
Maximum acceleration under shock load (during transport): 150 m/s² at 11 ms
Maximum acceleration under vibratory load (during storage): 10 m/s² at 13...200 Hz
Maximum acceleration under vibratory load (during transport): 10 m/s² at 13...200 Hz
Maximum acceleration under vibrational stress (during operation): 10 m/s² at 13...200 Hz
Maximum deflection under vibratory load (during storage): 1.5 mm at 2...13 Hz
Maximum deflection under vibratory load (during transport): 1.5 mm at 2...13 Hz
ambient air temperature for operation: -10…60 °C
Maximum deflection under vibratory load (during operation): 1.5 mm at 2...13 Hz
Overvoltage category: Class III
Regulation loop: Adjustable PID regulator
Electromagnetic emission: Radiated emissions environment 1 category C2 conforming to IEC 61800-3 2...16 kHz shielded motor cable; Conducted emissions with integrated EMC filter environment 1 category C1 conforming to IEC 61800-3 2, 4, 8, 12 and 16 kHz shielded motor cable <5 m; Conducted emissions with integrated EMC filter environment 1 category C2 conforming to IEC 61800-3 2...12 kHz shielded motor cable <5 m; Conducted emissions with integrated EMC filter environment 1 category C2 conforming to IEC 61800-3 2, 4 and 16 kHz shielded motor cable <10 m; Conducted emissions with additional EMC filter environment 1 category C1 conforming to IEC 61800-3 4...12 kHz shielded motor cable <20 m; Conducted emissions with additional EMC filter environment 1 category C2 conforming to IEC 61800-3 4...12 kHz shielded motor cable <50 m; Conducted emissions with additional EMC filter environment 2 category C3 conforming to IEC 61800-3 4...12 kHz shielded motor cable <50 m
Vibration resistance: 1 gn (f = 13…200 Hz) conforming to IEC 60068-2-6; 1.5 mm peak to peak (f = 3…13 Hz) - drive unmounted on symmetrical DIN rail - conforming to IEC 60068-2-6
Shock resistance: 15 gn conforming to IEC 60068-2-27 for 11 ms
Relative humidity: 5…95 % without condensation conforming to IEC 60068-2-3; 5…95 % without dripping water conforming to IEC 60068-2-3
Noise level: 0 dB
Pollution degree: 2
Ambient air transport temperature: -25…70 °C
Ambient air temperature for operation: -10…40 °C without derating; 40…60 °C with current derating 2.2 % per °C
Ambient air temperature for storage: -25…70 °C
Packing Units
Unit Type of Package 1: PCE
Number of Units in Package 1: 1
Package 1 Height: 12.000 cm
Package 1 Width: 18.600 cm
Package 1 Length: 19.000 cm
Package 1 Weight: 967.000 g
Unit Type of Package 2: P06
Number of Units in Package 2: 45
Package 2 Height: 75.000 cm
Package 2 Width: 60.000 cm
Package 2 Length: 80.000 cm
Package 2 Weight: 56.740 kg
Offer Sustainability
REACh Regulation: Reference contains Substances of Very High Concern above the threshold
EU RoHS Directive: Pro-active compliance (Product out of EU RoHS legal scope)
Mercury free: Yes
China RoHS Regulation: X
RoHS exemption information: Yes
WEEE: The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
© 2018 Alplan Kft.