Schneider-Electric
ATSU01N209LT
Tariff code: 8537109899
Link to the manufacturers site: ATSU01N209LT - soft starter for asynchronous motor - ATSU01 - 9 A - 200..480V - 1.5..4 KW
Main
Range of product: Altistart U01 and TeSys U
product or component type: Soft starter
Product destination: Asynchronous motors
Product specific application: Simple machine
Device short name: ATSU01
Network number of phases: 3 phases
[Us] rated supply voltage: 200...480 V - 10...10 %
Motor power kW: 4 kW, 3 phases at 400 V; 1.5 kW, 3 phases at 230 V
Motor power hp: 2 hp, 3 phases at 230 V; 5 hp, 3 phases at 460 V
IcL starter rating: 9 A
Utilisation category: AC-53B conforming to EN/IEC 60947-4-2
Current consumption: 65 mA
Type of start: Start with voltage ramp
Power dissipation in W: 1.5 W at full load and at end of starting; 91.5 W in transient state
Complementary
Assembly style: With heat sink
Function available: Integrated bypass
Supply voltage limits: 180…528 V
Supply frequency: 50...60 Hz - 5...5 %
Network frequency: 47.5...63 Hz
Output voltage: <= power supply voltage
[Uc] control circuit voltage: 24 V DC +/- 10 %
Starting time: 1 s / 100; 5 s / 20; 10 s / 10; Adjustable from 1 to 10 s
Deceleration time symb: Adjustable from 1 to 10 s
Starting torque: 30...80 % of starting torque of motor connected directly on the line supply
Discrete input type: Logic (LI1, LI2, BOOST) stop, run and boost on start-up functions <= 8 mA 27 kOhm
Discrete input voltage: 24...40 V
Input output isolation: Galvanic between power and control
Discrete input logic: Positive LI1, LI2, BOOST at State 0: < 5 V and <= 0.2 mA at State 1: > 13 V, >= 0.5 mA
Discrete output current: 2 A DC-13; 3 A AC-15
Discrete output type: Open collector logic LO1 end of starting signal; Relay outputs R1A, R1C NO
Discrete output voltage: 24 V (voltage limits: 6...30 V) open collector logic
Minimum switching current: 10 mA at 6 V DC for relay outputs
Maximum switching current: Relay outputs: 2 A at 30 V DC cos phi = 0.5 and L/R = 20 ms inductive load; Relay outputs: 2 A at 250 V AC AC-15 cos phi = 0.5 and L/R = 20 ms inductive load
Maximum switching voltage: 440 V relay outputs
Display type: 1 LED (green) for starter powered up; 1 LED (yellow) for nominal voltage reached
Tightening torque: 0.5 N.m; 1.9…2.5 N.m
Electrical connection: 4 mm screw clamp terminal - rigid 1 1...10 mm² AWG 8 power circuit; Screw connector - rigid without cable end 1 0.5...2.5 mm² AWG 14 control circuit; 4 mm screw clamp terminal - rigid 2 1...6 mm² AWG 10 power circuit; Screw connector - rigid 2 0.5...1 mm² AWG 17 control circuit; Screw connector - flexible with cable end 1 0.5...1.5 mm² AWG 16 control circuit; 4 mm screw clamp terminal - flexible without cable end 1 1.5...10 mm² AWG 8 power circuit; Screw connector - flexible without cable end 1 0.5...2.5 mm² AWG 14 control circuit; 4 mm screw clamp terminal - flexible with cable end 2 1...6 mm² AWG 10 power circuit; 4 mm screw clamp terminal - flexible without cable end 2 1.5...6 mm² AWG 10 power circuit; Screw connector - flexible without cable end 2 0.5...1.5 mm² AWG 16 control circuit
Marking: CE
Operating position: Vertical +/- 10 degree
Height: 234 mm
Width: 45 mm
Depth: 150 mm
Net weight: 0.34 kg
Power range: 1.1…2 kW at 200…240 V 3 phases; 2.2…3 kW at 380…440 V 3 phases; 4…6 kW
Motor starter type: Soft starter
Environment
Electromagnetic compatibility: Conducted and radiated emissions level B conforming to CISPR 11; Conducted and radiated emissions level B conforming to IEC 60947-4-2; Damped oscillating waves level 3 conforming to IEC 61000-4-12; Electrostatic discharge level 3 conforming to IEC 61000-4-2; EMC immunity conforming to EN 50082-1; EMC immunity level B conforming to EN 50082-2; Harmonics level 3 conforming to IEC 1000-3-2; Harmonics level 3 conforming to IEC 1000-3-4; Immunity to electrical transients level 4 conforming to IEC 61000-4-4; Immunity to radiated radio-electrical interference level 3 conforming to IEC 61000-4-3; Voltage/current impulse level 3 conforming to IEC 61000-4-5; Conducted and radiated emissions level 3 conforming to IEC 61000-4-6; Immunity to conducted interference caused by radio-electrical fields level 4 conforming to IEC 61000-4-11
Standards: EN/IEC 60947-4-2
Product certifications: UL; C-Tick; CSA; CCC
IP degree of protection: IP20
Pollution degree: 2 conforming to EN/IEC 60947-4-2
Vibration resistance: 1 gn (f= 13…150 Hz) conforming to EN/IEC 60068-2-6; 1.5 mm peak to peak (f= 3…13 Hz) conforming to EN/IEC 60068-2-6
Shock resistance: 15 gn for 11 ms conforming to EN/IEC 60068-2-27
Relative humidity: 5…95 % without condensation or dripping water conforming to EN/IEC 60068-2-3
Ambient air temperature for operation: -10…40 °C (without derating); 40…50 °C (with current derating of 2 % per °C)
Ambient air temperature for storage: -25…70 °C conforming to EN/IEC 60947-4-2
Operating altitude: <= 1000 m without derating; > 1000 m with current derating of 2.2 % per additional 100 m
Packing Units
Unit Type of Package 1: PCE
Number of Units in Package 1: 1
Package 1 Height: 6.500 cm
Package 1 Width: 18.500 cm
Package 1 Length: 16.500 cm
Package 1 Weight: 454.000 g
Unit Type of Package 2: S03
Number of Units in Package 2: 14
Package 2 Height: 30.000 cm
Package 2 Width: 30.000 cm
Package 2 Length: 40.000 cm
Package 2 Weight: 6.905 kg
Offer Sustainability
REACh Regulation: Free of Substances of Very High Concern above the threshold
REACh free of SVHC: Yes
EU RoHS Directive: Pro-active compliance (Product out of EU RoHS legal scope)
Toxic heavy metal free: Yes
Mercury free: Yes
China RoHS Regulation: X
RoHS exemption information: Yes
WEEE: The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
© 2018 Alplan Kft.