Link to the manufacturers site: XPSVNE3442P - Preventa XPSVNE biztonsági relé, nullsebeddég detektálás, 2NO+2 SSR jelzés, <=60Hz, 115 VAC, csavaros
Main
range of product: Preventa Safety automation
product or component type: Preventa safety module
safety module name: XPSVNE
safety module application: For zero speed detection
function of module: Monitoring XPS AK; Monitoring 3-phase motor with variable number of poles and star-delta starting; Monitoring 3-phase motor with star-delta starting; Monitoring 3-phase motor + variable speed drive; Monitoring star-delta motor starter and guard switch type XCS E; Monitoring 3-phase motor; Monitoring dc motor
safety level: Can reach PL d/category 3 conforming to EN/ISO 13849-1; Can reach SILCL 2 conforming to EN/IEC 62061
safety reliability data: MTTFd = 124.1 years conforming to EN/ISO 13849-1; DC > 99 % conforming to EN/ISO 13849-1; PFHd = 9.26E-9 1/h conforming to EN/IEC 62061
product certifications: UL; CSA; TÜV
[Us] rated supply voltage: 115 V AC - 15...15 %
output type: Relay, 1 NO + 1 NC circuit(s), volt-free
number of additional circuits: 2 solid state outputs
Complementary
product destination: For motor power supply <= 60 Hz
power consumption in VA: 7.5 VA
input voltage: 500 Vrms
input detection threshold: 0.01...0.1 V
breaking capacity: 180 VA holding AC-15 C300 relay output; 1800 VA inrush AC-15 C300 relay output
breaking capacity: 1.2 A at 24 V (DC-13) time constant: 50 ms for NC relay output circuit; 1.5 A at 24 V (DC-13) time constant: 50 ms for NO relay output circuit; 10 mA at 48 V for solid state output circuit; 20 mA at 24 V for solid state output circuit
[Ith] conventional free air thermal current: 2.5 A for relay output
associated fuse rating: 4 A gG for relay output conforming to EN/IEC 60947-5-1, DIN VDE 0660 part 200
standards: EN/IEC 60947-5-1; EN/IEC 60204-1
minimum output current: 10 mA for relay output
minimum output voltage: 17 V for relay output
[Ui] rated insulation voltage: 300 V (pollution degree 2) conforming to IEC 60947-5-1; 300 V (pollution degree 2) conforming to DIN VDE 0110 parts 1 and 2
[Uimp] rated impulse withstand voltage: 4 kV overvoltage category III conforming to IEC 60947-5-1; 4 kV overvoltage category III conforming to DIN VDE 0110 parts 1 and 2
local signalling: 4 LEDs
connections - terminals: Captive screw clamp terminals, removable terminal block flexible cable: 0.2...1.5 mm² without cable end, 2 wires; Captive screw clamp terminals, removable terminal block flexible cable: 0.2...2.5 mm² without cable end, 1 wire; Captive screw clamp terminals, removable terminal block flexible cable: 0.25...1 mm² with cable end, without bezel, 2 wires; Captive screw clamp terminals, removable terminal block flexible cable: 0.25...2.5 mm² with cable end, with bezel, 1 wire; Captive screw clamp terminals, removable terminal block flexible cable: 0.25...2.5 mm² with cable end, without bezel, 1 wire; Captive screw clamp terminals, removable terminal block flexible cable: 0.5...1.5 mm² with cable end, with double bezel, 2 wires; Captive screw clamp terminals, removable terminal block solid cable: 0.2...1 mm² without cable end, 2 wires; Captive screw clamp terminals, removable terminal block solid cable: 0.2...2.5 mm² without cable end, 1 wire
mounting support: 35 mm symmetrical DIN rail
depth: 114 mm
height: 99 mm
width: 45 mm
net weight: 0.6 kg
Environment
IP degree of protection: IP20 (terminals) conforming to EN/IEC 60529; IP40 (enclosure) conforming to EN/IEC 60529
ambient air temperature for operation: -10…55 °C
ambient air temperature for storage: -25…85 °C
Packing Units
Number of Units in Package 1: 1
Number of Units in Package 2: 12
Package 1 Height: 10.5 cm
Package 1 Length: 6.5 cm
Package 1 Weight: 380.0 g
Package 1 Width: 12.5 cm
Package 2 Height: 15.0 cm
Package 2 Length: 40.0 cm
Package 2 Weight: 5.015 kg
Package 2 Width: 30.0 cm
Unit Type of Package 1: PCE
Unit Type of Package 2: S02
Offer Sustainability
Sustainable offer status: Green Premium product
REACh Regulation: Reference contains Substances of Very High Concern above the threshold
EU RoHS Directive: Pro-active compliance (Product out of EU RoHS legal scope)
Mercury free: Yes
RoHS exemption information: Yes
China RoHS Regulation: X
Environmental Disclosure: ENVPEP1406024EN
Circularity Profile: ENVEOLI1406024EN
WEEE: The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins