Schneider-Electric
LP1K0901FD
Tariff code: 8536490099
Link to the manufacturers site: LP1K0901FD - TeSys K contactor - 3P - AC-3 <= 440 V 9 A - 1 NC aux. - 110 V DC coil
Main
Range of produc: TeSys K
Range: TeSys
Product or component type: Contactor
Device short name: LP1K
contactor application: Resistive load; Motor control
Complementary
utilisation category: AC-3; AC-3e; AC-1; AC-4
Poles description: 3P
Pole contact composition: 3 NO
[Ue] rated operational voltage: Power circuit: <= 690 V AC <= 400 Hz; Signalling circuit: <= 690 V AC <= 400 Hz
[Ie] rated operational current: 9 A (at <60 °C) at <= 440 V AC AC-3 for power circuit; 9 A (at <60 °C) at <= 440 V AC AC-3e for power circuit; 20 A (at <60 °C) at <= 690 V AC AC-1 for power circuit
Control circuit type: DC standard
[Uc] control circuit voltage: 110 V DC
Motor power kW: 2.2 kW at 220...230 V AC 50/60 Hz AC-3; 4 kW at 380...415 V AC 50/60 Hz AC-3; 4 kW at 440/690 V AC 50/60 Hz AC-3; 2.2 kW at 220...230 V AC 50/60 Hz AC-3e; 4 kW at 380...415 V AC 50/60 Hz AC-3e; 4 kW at 440/690 V AC 50/60 Hz AC-3e; 2.2 kW at 220...230 V AC 50/60 Hz AC-4; 4 kW at 380...415 V AC 50/60 Hz AC-4; 4 kW at 440/690 V AC 50/60 Hz AC-4
Auxiliary contact composition: 1 NC
[Uimp] rated impulse withstand voltage: 8 kV
Overvoltage category: III
[Ith] conventional free air thermal current: 20 A (at 60 °C) for power circuit; 10 A (at 50 °C) for signalling circuit
Irms rated making capacity: 110 A AC for power circuit conforming to IEC 60947; 110 A AC for signalling circuit conforming to IEC 60947
Rated breaking capacity: 110 A at 220...230 V conforming to IEC 60947; 110 A at 380...400 V conforming to IEC 60947; 110 A at 415 V conforming to IEC 60947; 110 A at 440 V conforming to IEC 60947; 80 A at 500 V conforming to IEC 60947; 70 A at 660...690 V conforming to IEC 60947
[Icw] rated short-time withstand current: 90 A 50 °C - 1 s for power circuit; 85 A 50 °C - 5 s for power circuit; 80 A 50 °C - 10 s for power circuit; 60 A 50 °C - 30 s for power circuit; 45 A 50 °C - 1 min for power circuit; 40 A 50 °C - 3 min for power circuit; 20 A 50 °C - >= 15 min for power circuit; 80 A - 1 s for signalling circuit; 90 A - 500 ms for signalling circuit; 110 A - 100 ms for signalling circuit
Associated fuse rating: 25 A gG at <= 440 V for power circuit; 25 A aM for power circuit; 10 A gG for signalling circuit conforming to IEC 60947; 10 A gG for signalling circuit conforming to VDE 0660
Average impedance: 3 mOhm - Ith 20 A 50 Hz for power circuit
[Ui] rated insulation voltage: Power circuit: 600 V conforming to UL 508; Power circuit: 690 V conforming to IEC 60947-4-1; Signalling circuit: 690 V conforming to IEC 60947-4-1; Signalling circuit: 690 V conforming to IEC 60947-5-1; Signalling circuit: 600 V conforming to UL 508; Power circuit: 600 V conforming to CSA C22.2 No 14; Signalling circuit: 600 V conforming to CSA C22.2 No 14
Insulation resistance: > 10 MOhm for signalling circuit
Inrush power in W: 3 W (at 20 °C)
Hold-in power consumption in W: 3 W at 20 °C
Heat dissipation: 1.3 W
Control circuit voltage limits: Operational: 0.8...1.15 Uc (at <50 °C); Drop-out: >= 0.10 Uc (at <50 °C)
Connections - terminals: Screw clamp terminals 1 cable(s) 1.5…4 mm²solid; Screw clamp terminals 1 cable(s) 0.75…4 mm²flexible without cable end; Screw clamp terminals 1 cable(s) 0.34…2.5 mm²flexible with cable end; Screw clamp terminals 2 cable(s) 1.5…4 mm²solid; Screw clamp terminals 2 cable(s) 0.75…4 mm²flexible without cable end; Screw clamp terminals 2 cable(s) 0.34…1.5 mm²flexible with cable end; Power circuit: screw clamp terminals 2 cable(s) 1.5 mm²flexible with cable end
Maximum operating rate: 3600 cyc/h
Auxiliary contacts type: type instantaneous 1 NC
Minimum switching current: 5 mA for signalling circuit
Minimum switching voltage: 17 V for signalling circuit
mounting support: Plate; Rail
Tightening torque: 0.8…1.3 N.m - on screw clamp terminals Philips No 2; 0.8…1.3 N.m - on screw clamp terminals flat Ø 6 mm; 0.8…1.3 N.m - on screw clamp terminals pozidriv No 2
Operating time: 30...40 ms coil energisation and NO closing; 10 ms coil de-energisation and NO opening
Safety reliability level: B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1; B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
Mechanical durability: 10 Mcycles
Electrical durability: 1.3 Mcycles 9 A AC-3 at Ue <= 440 V; 1.3 Mcycles 9 A AC-3e at Ue <= 440 V; 0.16 Mcycles 20 A AC-1 at Ue <= 690 V; 0.02 Mcycles 54 A AC-4 at Ue <= 440 V
height: 58 mm
Width: 45 mm
Depth: 57 mm
Net weight: 0.225 kg
Compatibility code: LP1K
Environment
Standards: EN/IEC 60947-4-1; EN/IEC 60947-5-1; UL 60947-4-1; UL 60947-5-1; CSA C22.2 No 60947-4-1; CSA C22.2 No 60947-5-1; GB/T 14048.4
product certifications: CB Scheme; CCC; UL; CSA; EAC; CE; UKCA
IP degree of protection: IP2X
Ambient air temperature for operation: -25…50 °C
Ambient air temperature for storage: -50…80 °C
Operating altitude: 2000 m without derating
Flame retardance: V1 conforming to UL 94; Requirement 2 conforming to NF F 16-101; Requirement 2 conforming to NF F 16-102
Packing Units
Unit Type of Package 1: PCE
Number of Units in Package 1: 1
Package 1 Height: 4.9 cm
Package 1 Width: 6.2 cm
Package 1 Length: 6.8 cm
Package 1 Weight: 215 g
Unit Type of Package 2: S02
Number of Units in Package 2: 40
Package 2 Height: 15 cm
Package 2 Width: 30 cm
Package 2 Length: 40 cm
Package 2 Weight: 9.095 kg
Unit Type of Package 3: P06
Number of Units in Package 3: 640
Package 3 Height: 75 cm
Package 3 Width: 40 cm
Package 3 Length: 80 cm
Package 3 Weight: 156 kg
Offer Sustainability
Sustainable offer status: Green Premium product
REACh Regulation: Free of Substances of Very High Concern above the threshold
REACh free of SVHC: Yes
EU RoHS Directive: Compliant
Toxic heavy metal free: Yes
Mercury free: Yes
China RoHS Regulation: Pro-active China RoHS declaration (out of China RoHS legal scope)
RoHS exemption information: Yes
Environmental Disclosure: ENVPEP1503003EN
Circularity Profile: ENVEOLI1503003EN
WEEE: The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
© 2018 Alplan Kft.