Schneider-Electric
XPSBCE3110P
Tariff code:
This product is discontinued.
Please contact us for possible replacement product options.
Link to the manufacturers site: XPSBCE3110P - module XPSBCE - two-hand control - 24 V AC/DC
Main
range of product: Preventa Safety automation
product or component type: Preventa safety module
safety module name: XPSBCE
safety module application: For electrical monitoring of two-hand control stations
function of module: Monitoring two-hand control station
safety level: Can reach PL e/category 4 conforming to EN/ISO 13849-1; Can reach SILCL 3 conforming to EN/IEC 62061
safety reliability data: DC > 99 % conforming to EN/ISO 13849-1; MTTFd = 37 years conforming to EN/ISO 13849-1; PFHd = 3E-8 1/h conforming to EN/IEC 62061
connections - terminals: Captive screw clamp terminals, removable terminal block, 1 x 0.25...1 x 1.5 mm² flexible with cable end, with bezel; Captive screw clamp terminals, removable terminal block, 1 x 0.25...1 x 2.5 mm² flexible with cable end, without bezel; Captive screw clamp terminals, removable terminal block, 2 x 0.25...2 x 1 mm² flexible with cable end, without bezel; Captive screw clamp terminals, removable terminal block, 2 x 0.5...2 x 1.5 mm² flexible with cable end, with double bezel; Captive screw clamp terminals, removable terminal block, 1 x 0.2...1 x 2.5 mm² solid without cable end; Captive screw clamp terminals, removable terminal block, 1 x 0.2...1 x 2.5 mm² flexible without cable end; Captive screw clamp terminals, removable terminal block, 2 x 0.2...2 x 1 mm² solid without cable end; Captive screw clamp terminals, removable terminal block, 2 x 0.2...2 x 1 mm² flexible without cable end
output type: Relay, 2 NO circuit(s), volt-free
number of additional circuits: 1 NC
[Us] rated supply voltage: 24 V AC/DC - 15...10 %
Complementary
synchronisation time between inputs: 0.5 s
supply frequency: 50/60 Hz
power consumption in VA: 4 VA
input protection type: Internal, electronic
number of inputs: 1 NC + NO
input compatibility: Two-hand control conforming to EN 574/ISO 13851-III C
[Uc] control circuit voltage: 24 V DC
breaking capacity: 3600 VA inrush AC-15 B300 relay output; 360 VA holding AC-15 B300 relay output
breaking capacity: 1.5 A at 24 V (DC-13) time constant: 50 ms for relay output
[Ith] conventional free air thermal current: 6 A
associated fuse rating: 6 A gG for relay output conforming to EN/IEC 60947-5-1, DIN VDE 0660 part 200
minimum output current: 10 mA for relay output
minimum output voltage: 17 V for relay output
maximum response time on input open: 50 ms
[Ui] rated insulation voltage: 300 V (pollution degree 2) conforming to IEC 60947-5-1; 300 V (pollution degree 2) conforming to DIN VDE 0110 part 1
[Uimp] rated impulse withstand voltage: 4 kV overvoltage category III conforming to IEC 60947-5-1; 4 kV overvoltage category III conforming to DIN VDE 0110 part 1
local signalling: 3 LEDs
mounting support: 35 mm symmetrical DIN rail
net weight: 0.272 kg
Environment
standards: EN 574 type III C/ISO 13851; EN/IEC 60947-5-1; EN/IEC 60204-1
product certifications: UL; CSA; BG
IP degree of protection: IP20 (terminals) conforming to EN/IEC 60529; IP40 (enclosure) conforming to EN/IEC 60529
ambient air temperature for operation: -25…55 °C
ambient air temperature for storage: -25…75 °C
Offer Sustainability
Sustainable offer status: Green Premium product
REACh Regulation: Reference contains Substances of Very High Concern above the threshold
EU RoHS Directive: Pro-active compliance (Product out of EU RoHS legal scope)
Toxic heavy metal free: Yes
Mercury free: Yes
RoHS exemption information: Yes
China RoHS Regulation: X
Environmental Disclosure: ENVPEP1406024EN
Circularity Profile: ENVEOLI1406024EN
WEEE: The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
PVC free: Yes