SSL1A12BDR
Tariff code: 8536490099
Link to the manufacturers site: SSL1A12BDR - solid state relay,Plug-in,input 15-30 V DC, output 24-280 V AC, 2A
Main
Range of product: Harmony Solid State Relays
Device short name: SSL
Product or component type: Plug-in relay
Network number of phases: 1 phase
[Uc] control circuit voltage: 15...30 V
Output switching mode: Random voltage switching
Short-circuit current: 5000 A
Associated fuse rating: 2.5 A at 250 V coordination type 1
[Ui] rated insulation voltage: 280 V
Insulation resistance: > 100 MOhm at 500 V DC
Electromagnetic compatibility: Electrostatic discharge - test level: 4 kV criteria B (contact discharge) conforming to IEC 61000-4-2; Electrostatic discharge - test level: 8 kV criteria B (air discharge) conforming to IEC 61000-4-2; Conducted RF disturbances - test level: 10 V criteria A (0.15...80 MHz) conforming to IEC 61000-4-6; Electrical fast transient/burst immunity test - test level: 2 kV criteria B (5 kHz) conforming to IEC 61000-4-4; Electrical fast transient/burst immunity test - test level: 1 kV criteria B (5 kHz) conforming to IEC 61000-4-4; Surge immunity test - test level: 1 kV criteria B (line to line) conforming to IEC 61000-4-5; Surge immunity test - test level: 2 kV criteria B (line to earth) conforming to IEC 61000-4-5; Surge immunity test - test level: 1 kV criteria B (line to earth) conforming to IEC 61000-4-5; Radiated emission - test level: 30...1000 Mhz conforming to IEC 60947-1; Conducted emission - test level: 0.15...30 Mhz conforming to IEC 60947-1
[Uimp] rated impulse withstand voltage: 4.0 kV for input to case conforming to IEC 62314; 4.0 kV for input/output circuit conforming to UL 508; 4.0 kV for input/output circuit conforming to IEC 62314; 4.0 kV output to case; 4.0 kV output to case conforming to IEC 62314; 4.0 kV for input to case conforming to UL 508; 4.0 kV output to case conforming to UL 508
Complementary
Mounting support: Socket
[In] rated current: 2 A
Output voltage: 24...280 V AC
[Uc] control circuit voltage: 15...30 V DC
Capacitance unbalance: 2.5 pF input/output
Minimum switching voltage: 15 V DC turn-on
Maximum switching voltage: 10 V DC turn-off
Input current: 6 mA
Input impedance: 2500 Ohm
Solid state output type: SCR output; Random voltage switching
Load current: 0.07…2 A
Absolute maximum voltage: 600 V
Surge current: 84 A for 16.6 ms; 80 A for 20 ms
Maximum voltage drop: <1.5 V on-state
Maximum I²t for fusing: 33 A².s for 10 ms at 50 Hz; 29 A².s for 8.3 ms at 60 Hz
Maximum leakage current: 4 mA off-state
DV/dt: 500 V/µs off-state at maximum voltage
Response time: 0.5 cycle (turn-off); 0.1 ms (turn-on)
Overvoltage category: III
Width: 5 mm
Height: 28 mm
Depth: 15 mm
Net weight: 0.0041 kg
Device presentation: Complete product
Environment
Flame retardance: V0 conforming to UL 94
Dielectric strength: 2500 V for input/output
pollution degree: 2
Standards: IEC/EN 60947-4-3; IEC/EN 62314; UL 508; C22.2 No. 14
Product certifications: cURus; CSA; EAC; CE; UKCA
Marking: CE
IP degree of protection: IP00
Ambient air temperature for operation: -20…80 °C
Ambient air temperature for storage: -20…85 °C
Packing Units
Unit Type of Package 1: PCE
Number of Units in Package 1: 1
Package 1 Height: 0.700 cm
Package 1 Width: 2.500 cm
Package 1 Length: 37.000 cm
Package 1 Weight: 4.000 g
Unit Type of Package 2: BB1
Number of Units in Package 2: 12
Package 2 Height: 0.700 cm
Package 2 Width: 2.500 cm
Package 2 Length: 37.000 cm
Package 2 Weight: 61.000 g
Unit Type of Package 3: S01
Number of Units in Package 3: 1080
Package 3 Height: 15.000 cm
Package 3 Width: 15.000 cm
Package 3 Length: 40.000 cm
Package 3 Weight: 5.872 kg
Offer Sustainability
REACh Regulation: Reference contains Substances of Very High Concern above the threshold
EU RoHS Directive: Pro-active compliance (Product out of EU RoHS legal scope)
Environmental Disclosure: ENVPEP1307068EN
Circularity Profile: NA
Take-back: No
Carbon footprint (kg.eq.CO2 per CR, Total Life cycle) : 10