Skip to main content

Schneider-Electric
RE22R2MMU

Multifunction Timer Relay - 24VDC/24..240 V AC - 2 C/O
Net discounted price 52.85 EUR
In stock: 3 pc(s)
Barcode: 3606480676581
Tariff code: 8536490099

Link to the manufacturers site: RE22R2MMU - Multifunction Timer Relay - 24VDC/24..240 V AC - 2 C/O

Main

Range of produc: Harmony Timer Relays

Product or component type: Multifunction relay

Discrete output type: Relay

Device short name: RE22

Nominal output current: 8 A

[Uc] control circuit voltage: 24 V; 24...240 V

Contacts type and composition: 2 C/O

Connections - terminals: Screw connectors

[In] rated current: 5 A

Output type: Relay

Complementary

Contacts type and composition: 1 C/O timed contact; 1 C/O timed or instantaneous contact

Time delay type: Power on-delay; On-delay and off-delay; Interval; Off-delay; Symmetrical flashing

Time delay range: 10...100 h; 6...60 s; 0.1...1 s; 1...10 h; 1...10 s; 1...10 min; 6...60 min

Control type: Rotary knob front panel

[Us] rated supply voltage: 24...240 V AC; 24 V DC

Voltage range: 0.85...1.1 Us

Supply frequency: 50...60 Hz +/- 5 %

Connections - terminals: Screw terminals, 2 x 1.5 mm² with cable end; Screw terminals, 2 x 2.5 mm² without cable end

Tightening torque: 0.6…1 N.m conforming to IEC 60947-1

Housing material: Self-extinguishing

Repeat accuracy: +/- 0.5 % conforming to IEC 61812-1

Temperature drift: +/- 0.05 %/°C

Voltage drift: +/- 0.2 %/V

Setting accuracy of time delay: +/- 10 % of full scale at 25 °C conforming to IEC 61812-1

Minimum pulse duration: 30 ms; 100 ms under load

Insulation resistance: 100 MOhm at 500 V DC conforming to IEC 60664-1

Reset time: 120 ms on de-energisation

Immunity to microbreaks: 10 ms

Power consumption in VA: 50 VA at 240 V AC

Power consumption in W: 0.7 W at 24 V DC

Breaking capacity: 2000 VA

Minimum switching current: 10 mA at 5 V

Maximum switching current: 8 mA

Maximum switching voltage: 250 V

Electrical durability: 100000 cycles for resistive load, 8 A at 250 V, AC

Mechanical durability: 10000000 cycles

[Uimp] rated impulse withstand voltage: 5 kV for 1.2…50 µs conforming to IEC 60664-1; 5 kV conforming to IEC 61812-1

Maximum delay response: 100 ms

Safety reliability data: MTTFd = 182.6 years; B10d = 170000

Mounting position: Any position in relation to normal vertical mounting plane

Mounting support: 35 mm DIN rail conforming to IEC 60715

Status LED: LED green (flashing) for timing in progress; LED green (steady) for power ON; LED yellow for relay energised

Width: 22.5 mm

Net weight: 0.09 kg

Time delay type: A, Ac, At, B, Bw, C, D, Di, H, Ht

Contacts type and composition: 2 C/O

Functionality: Multifunction

Environment

Dielectric strength: 2.5 kV for 1 mA/1 minute at 50 Hz conforming to IEC 61812-1

Standards: IEC 61812-1; IEC 61000-6-1; IEC 61000-6-2; IEC 61000-6-3; IEC 61000-6-4

Directives: 2004/108/EC - electromagnetic compatibility; 2006/95/EC - low voltage directive

product certifications: cULus; CSA; CE; CCC; RCM; GL; EAC

ambient air temperature for operation: -20…60 °C

Ambient air temperature for storage: -30…60 °C

IP degree of protection: IP40 housing: conforming to IEC 60529; IP20 terminal block: conforming to IEC 60529; IP40 front face: conforming to IEC 60529

Vibration resistance: 20 m/s² (f= 10…150 Hz) conforming to IEC 60068-2-6

Shock resistance: 15 gn for 11 ms conforming to IEC 60068-2-27

Relative humidity: 93 %, without condensation conforming to IEC 60068-2-30

Electromagnetic compatibility: Electrostatic discharge immunity test - test level: 6 kV level 3 (contact discharge) conforming to IEC 61000-4-2; Electrostatic discharge immunity test - test level: 8 kV level 3 (air discharge) conforming to IEC 61000-4-2; Fast transients immunity test - test level: 1 kV level 3 (capacitive connecting clip) conforming to IEC 61000-4-4; Fast transients immunity test - test level: 2 kV level 3 (direct contact) conforming to IEC 61000-4-4; Surge immunity test - test level: 1 kV level 3 (differential mode) conforming to IEC 61000-4-5; Surge immunity test - test level: 2 kV level 3 (common mode) conforming to IEC 61000-4-5; Radiated radio-frequency electromagnetic field immunity test - test level: 10 V level 3 (0.15...80 MHz) conforming to IEC 61000-4-6; Electromagnetic field immunity test - test level: 10 V/m level 3 (80 MHz...1 GHz) conforming to IEC 61000-4-3; Immunity to microbreaks and voltage drops - test level: 30 % (500 ms) conforming to IEC 61000-4-11; Immunity to microbreaks and voltage drops - test level: 100 % (20 ms) conforming to IEC 61000-4-11; Conducted and radiated emissions class B conforming to EN 55022

Packing Units

Unit Type of Package 1: PCE

Number of Units in Package 1: 1

Package 1 Height: 2.500 cm

Package 1 Width: 8.200 cm

Package 1 Length: 9.500 cm

Package 1 Weight: 105.000 g

Unit Type of Package 2: S02

Number of Units in Package 2: 40

Package 2 Height: 15.000 cm

Package 2 Width: 30.000 cm

Package 2 Length: 40.000 cm

Package 2 Weight: 4.667 kg

Offer Sustainability

Sustainable offer status: Green Premium product

REACh Regulation: Reference contains Substances of Very High Concern above the threshold

EU RoHS Directive: Pro-active compliance (Product out of EU RoHS legal scope)

Mercury free: Yes

China RoHS Regulation: X

RoHS exemption information: Yes

Environmental Disclosure: ENVPEP1401008EN

Circularity Profile: ENVEOLI1401008EN

© 2018 Alplan Kft.