Skip to main content

Schneider-Electric
LUCM1XBL

multifunction control unit LUCM - class 5...30 - 0.35...1.4 A - 24 V DC
In stock: 1 pc(s)
Barcode: 3389110365092
Tariff code: 8537109899

This product is discontinued.

This product is no longer manufactured, but we have it in stock. Please contact us for price and delivery information!

Link to the manufacturers site: LUCM1XBL - multifunction control unit LUCM - class 5...30 - 0.35...1.4 A - 24 V DC

Main

Range: TeSys

Range of product: TeSys Ultra

Product name: TeSys Ultra

Device short name: LUCM

Product or component type: Multifunction control unit

Device application: Motor control; Motor protection

Product specific application: Most sophisticated control and protection requirements, with display

Function available: Protection against phase failure and phase imbalance; Protection function alarm; Protection against overload and short-circuit; Log function; Earth fault protection; Monitoring function, indication of main motor parameters; Differentiation of thermal overload and magnetic fault; Overload, no-load running; Manual or automatic reset

Product compatibility: Power base LUB12; Power base LUB32; Power base LUB38; Power base LUB120; Power base LUB320; Power base LUB380; Reversing contactor breaker LU2B12BL; Reversing contactor breaker LU2B32BL; Reversing contactor breaker LU2B38BL

[Ue] rated operational voltage: 690 V AC

Network frequency: 40...60 Hz

Load type: 3-phase motor - cooling: self-cooled - setting factory setting; 3-phase motor - cooling: self-cooled, force cooled - setting settable; Single-phase motor - cooling: self-cooled, force cooled - setting settable

Utilisation category: AC-43; AC-44; AC-41

Motor power kW: 0.25 kW at 400...440 V AC 50/60 Hz for 3 phases motors; 0.09 kW at 400...440 V AC 50/60 Hz for 1 phase motors

Thermal protection adjustment range: 0.35…1.4 A

Thermal overload class: Class 5…30 - frequency limit: 50…60 Hz - temperature compensation: -25…55 °C conforming to IEC 60947-6-2; Class 5…30 - frequency limit: 50…60 Hz - temperature compensation: -25…55 °C conforming to UL 508

Tripping threshold: 14.2 x Ir +/- 20 %

[Uc] control circuit voltage: 24 V DC

Complementary

Control circuit voltage limits: 20...28 V for DC circuit 24 V in operation; 14.5 V for DC circuit 24 V drop-out

Typical current consumption: 150 mA at 24 V DC I maximum while closing with LUB12; 200 mA at 24 V DC I maximum while closing with LUB32; 200 mA at 24 V DC I maximum while closing with LUB38; 70 mA at 24 V DC I rms sealed with LUB12; 75 mA at 24 V DC I rms sealed with LUB32; 75 mA at 24 V DC I rms sealed with LUB38

Heat dissipation: 1.7 W for control circuit with LUB12; 1.8 W for control circuit with LUB32; 1.8 W for control circuit with LUB38; 0.8 W for external auxiliary circuit

Operating time: 35 ms opening with LUB12 for control circuit; 35 ms opening with LUB32 for control circuit; 35 ms opening with LUB38 for control circuit; 75 ms closing with LUB12 for control circuit; 65 ms closing with LUB32 for control circuit; 65 ms closing with LUB38 for control circuit

Physical interface: RS485 multidrop - connector(s): RJ45 - location: front panel - communication protocol: Modbus RTU 19200 bit/s

Return time: <= 200 ms

Messages display capacity: 2 lines of 12 characters - display LCD - English - accuracy +/- 5 % - resolution 1 % of Ir; 2 lines of 12 characters - display LCD - French - accuracy +/- 5 % - resolution 1 % of Ir; 2 lines of 12 characters - display LCD - German - accuracy +/- 5 % - resolution 1 % of Ir; 2 lines of 12 characters - display LCD - Italian - accuracy +/- 5 % - resolution 1 % of Ir; 2 lines of 12 characters - display LCD - Spanish - accuracy +/- 5 % - resolution 1 % of Ir

Reset: Automatic reset - setting: setting range; Manual - setting: factory setting; Manual - setting: setting range; Remote reset - setting: setting range

Time before reset: 1…1000 s - reset manual or automatic reset - setting settable; 120 s - reset manual - setting factory setting

User language: English - setting factory setting; English, French, German, Italian, Spanish - setting settable

Information displayed: Average current (factory setting); Average current (settable); Cause of last 5 faults (settable); Current in phase (settable); Earth leakage current (settable); Phase imbalance (settable); Thermal state of motor (settable)

Standards: EN 60947-6-2; IEC 60947-6-2; UL 60947-4-1, with phase barrier; CSA C22.2 No 60947-4-1, with phase barrier

Product certifications: CE; UL; CSA; CCC; EAC; ASEFA; ATEX; Marine

[Ui] rated insulation voltage: 690 V conforming to IEC 60947-6-2; 600 V conforming to UL 60947-4-1; 600 V conforming to CSA C22.2 No 60947-4-1

[Uimp] rated impulse withstand voltage: 6 kV conforming to IEC 60947-6-2

Safe separation of circuit: 400 V SELV between the control and auxiliary circuits conforming to IEC 60947-1; 400 V SELV between the control or auxiliary circuit and the main circuit conforming to IEC 60947-1

Fixing mode: Plug-in (front face)

Width: 45 mm

Height: 66 mm

Depth: 60 mm

Net weight: 0.175 kg

Compatibility code: LUCM

Environment

IP degree of protection: IP20 front panel and wired terminals conforming to IEC 60947-1; IP20 other faces conforming to IEC 60947-1; IP40 front panel outside connection zone conforming to IEC 60947-1

Protective treatment: TH conforming to IEC 60068

Ambient air temperature for operation: -25…60 °C

Ambient air temperature for storage: -40…85 °C

Operating altitude: 2000 m

Fire resistance: 960 °C parts supporting live components conforming to IEC 60695-2-12; 650 °C conforming to IEC 60695-2-12

Shock resistance: 10 gn power poles open conforming to IEC 60068-2-27; 15 gn power poles closed conforming to IEC 60068-2-27

Vibration resistance: 2 gn, 5…300 Hz, power poles open conforming to IEC 60068-2-6; 4 gn, 5…300 Hz, power poles closed conforming to IEC 60068-2-6

Resistance to electrostatic discharge: 8 kV level 3 in open air conforming to IEC 61000-4-2; 8 kV level 4 on contact conforming to IEC 61000-4-2

Non-dissipating shock wave: 1 kV serial mode conforming to IEC 60947-6-2; 2 kV common mode conforming to IEC 60947-6-2

Resistance to radiated fields: 10 V/m 3 conforming to IEC 61000-4-3

Resistance to fast transients: 2 kV class 3 serial link conforming to IEC 61000-4-4; 4 kV class 4 all circuits except for serial link conforming to IEC 61000-4-4

Immunity to radioelectric fields: 10 V conforming to IEC 61000-4-6

Immunity to microbreaks: 3 ms

Immunity to voltage dips: 70 % / 500 ms conforming to IEC 61000-4-11

Packing Units

Unit Type of Package 1: Db

Number of Units in Package 1: 1

Package 1 Height: 5.6 cm

Package 1 Width: 8.5 cm

Package 1 Length: 10.0 cm

Package 1 Weight: 175.0 g

Unit Type of Package 2: S02

Number of Units in Package 2: 23

Package 2 Height: 15.0 cm

Package 2 Width: 30.0 cm

Package 2 Length: 40.0 cm

Package 2 Weight: 4.349 kg

Offer Sustainability

Sustainable offer status: Green Premium product

REACh Regulation: Reference contains Substances of Very High Concern above the threshold

EU RoHS Directive: Compliant

Mercury free: Yes

China RoHS Regulation: Product out of China RoHS scope. Substance declaration for your information

RoHS exemption information: Yes

Environmental Disclosure: ENVPEP080204EN

Circularity Profile: ENVEOLI100414

WEEE: The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins

PVC free: Yes

Halogen content performance: Halogen free plastic parts product