Schneider-Electric
LUCD32FU
Tariff code:
This product is discontinued.
Please contact us for possible replacement product options.
Link to the manufacturers site: LUCD32FU - advanced control unit LUCD - class 20 - 8...32 A - 110...220 V DC/AC
Main
range: TeSys
range of product: TeSys U
product name: TeSys U
device short name: LUCD
product or component type: Advanced control unit
device application: Motor control; Motor protection
product specific application: Basic protection and advanced functions, communication
function available: Protection against overload and short-circuit; Manual reset; Protection against phase failure and phase imbalance; Earth fault protection
product compatibility: Power base LUB32; Power base LUB38; Power base LUB320; Power base LUB380; Reversing contactor breaker LU2B32FU; Reversing contactor breaker LU2B38FU
[Ue] rated operational voltage: 690 V AC
network frequency: 40...60 Hz
load type: 3-phase motor - cooling: self-cooled
utilisation category: AC-44; AC-41; AC-43
motor power kW: 15 kW at 400...440 V AC 50/60 Hz; 15 kW at 500 V AC 50/60 Hz; 18.5 kW at 690 V AC 50/60 Hz
thermal protection adjustment range: 8…32 A
thermal overload class: Class 20 - frequency limit: 40…60 Hz - temperature compensation: -25…70 °C conforming to IEC 60947-6-2; Class 20 - frequency limit: 40…60 Hz - temperature compensation: -25…70 °C conforming to UL 508
tripping threshold: 14.2 x Ir +/- 20 %
phase failure sensitivity: Yes
[Uc] control circuit voltage: 110...240 V AC; 110...220 V DC
Complementary
control circuit voltage limits: 88...264 V for AC circuit 110...240 V in operation; 88...242 V for DC circuit 110...220 V in operation; 55 V for AC circuit 110...240 V drop-out; 55 V for DC circuit 110...220 V drop-out
typical current consumption: 280 mA at 110...240 V AC I maximum while closing with LUB32; 280 mA at 110...240 V AC I maximum while closing with LUB38; 280 mA at 110...220 V DC I maximum while closing with LUB32; 280 mA at 110...220 V DC I maximum while closing with LUB38; 25 mA at 110...240 V AC I rms sealed with LUB32; 25 mA at 110...240 V AC I rms sealed with LUB38; 25 mA at 110...220 V DC I rms sealed with LUB32; 25 mA at 110...220 V DC I rms sealed with LUB38
heat dissipation: 3 W for control circuit with LUB32; 3 W for control circuit with LUB38
operating time: 35 ms opening with LUB32 for control circuit; 35 ms opening with LUB38 for control circuit; 50 ms closing with LUB32 for control circuit; 50 ms closing with LUB38 for control circuit
reset: Manual reset
standards: EN 60947-6-2; IEC 60947-6-2; UL 60947-4-1, with phase barrier; CSA C22.2 No 60947-4-1, with phase barrier
product certifications: CE; UL; CSA; CCC; EAC; ASEFA; ATEX; Marine
[Ui] rated insulation voltage: 690 V conforming to IEC 60947-6-2; 600 V conforming to UL 60947-4-1; 600 V conforming to CSA C22.2 No 60947-4-1
[Uimp] rated impulse withstand voltage: 6 kV conforming to IEC 60947-6-2
safe separation of circuit: 400 V SELV between the control and auxiliary circuits conforming to IEC 60947-1; 400 V SELV between the control or auxiliary circuit and the main circuit conforming to IEC 60947-1
fixing mode: Plug-in (front face)
width: 45 mm
height: 66 mm
depth: 60 mm
compatibility code: LUCD
Environment
IP degree of protection: IP20 front panel and wired terminals conforming to IEC 60947-1; IP20 other faces conforming to IEC 60947-1; IP40 front panel outside connection zone conforming to IEC 60947-1
protective treatment: TH conforming to IEC 60068
ambient air temperature for operation: -25…70 °C
ambient air temperature for storage: -40…85 °C
operating altitude: 2000 m
fire resistance: 960 °C parts supporting live components conforming to IEC 60695-2-12; 650 °C conforming to IEC 60695-2-12
shock resistance: 10 gn power poles open conforming to IEC 60068-2-27; 15 gn power poles closed conforming to IEC 60068-2-27
vibration resistance: 2 gn, 5…300 Hz, power poles open conforming to IEC 60068-2-6; 4 gn, 5…300 Hz, power poles closed conforming to IEC 60068-2-6
resistance to electrostatic discharge: 8 kV level 3 in open air conforming to IEC 61000-4-2; 8 kV level 4 on contact conforming to IEC 61000-4-2
non-dissipating shock wave: 1 kV serial mode conforming to IEC 60947-6-2; 2 kV common mode conforming to IEC 60947-6-2
resistance to radiated fields: 10 V/m 3 conforming to IEC 61000-4-3
resistance to fast transients: 2 kV class 3 serial link conforming to IEC 61000-4-4; 4 kV class 4 all circuits except for serial link conforming to IEC 61000-4-4
immunity to radioelectric fields: 10 V conforming to IEC 61000-4-6
immunity to microbreaks: 3 ms
immunity to voltage dips: 70 % / 500 ms conforming to IEC 61000-4-11
Offer Sustainability
Sustainable offer status: Green Premium product
REACh Regulation: Free of Substances of Very High Concern above the threshold
EU RoHS Directive: Compliant
Mercury free: Yes
RoHS exemption information: Yes
China RoHS Regulation: Product out of China RoHS scope. Substance declaration for your information
Environmental Disclosure: ENVPEP080204EN
Circularity Profile: ENVEOLI100414
WEEE: The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
PVC free: Yes
Halogen content performance: Halogen free plastic parts product