Skip to main content

Schneider-Electric
LC1F185

TeSys F contactor - 3P(3 NO) - AC-3 - <= 440 V 185 A - without coil
Barcode: 3389110122381
Tariff code: 8536490099

This product is discontinued.

Please contact us for possible replacement product options.

Link to the manufacturers site: LC1F185 - TeSys F contactor - 3P(3 NO) - AC-3 - <= 440 V 185 A - without coil

Main

range of product: TeSys F

range: TeSys

product name: TeSys F

product or component type: Contactor

device short name: LC1F

contactor application: Resistive load; Motor control

utilisation category: AC-3; AC-4; AC-1

poles description: 3P

pole contact composition: 3 NO

[Ue] rated operational voltage: <= 690 V AC 50/60 Hz; <= 460 V DC

[Ie] rated operational current: 275 A (at <40 °C) at <= 440 V AC-1; 185 A (at <55 °C) at <= 440 V AC-3

motor power kW: 100 kW at 415 V AC 50/60 Hz (AC-3); 100 kW at 440 V AC 50/60 Hz (AC-3); 110 kW at 500 V AC 50/60 Hz (AC-3); 90 kW at 380...400 V AC 50/60 Hz (AC-3); 55 kW at 220...240 V AC 50/60 Hz (AC-3); 110 kW at 660...690 V AC 50/60 Hz (AC-3); 33 kW at 400 V AC 50/60 Hz (AC-4)

Complementary

[Uc] control circuit voltage: 24...575 V AC 40...400 Hz with LX9 coil; 24...460 V DC with LX4 coil; 100...250 V AC 50/60 Hz with LXE coil; 100...380 V DC with LXE coil

[Uimp] rated impulse withstand voltage: 8 kV

overvoltage category: III

[Ith] conventional free air thermal current: 275 A (at 40 °C)

Irms rated making capacity: 1850 A conforming to IEC 60947-4-1

rated breaking capacity: 1480 A conforming to IEC 60947-4-1

[Icw] rated short-time withstand current: 1500 A 40 °C - 10 s; 920 A 40 °C - 30 s; 740 A 40 °C - 1 min; 500 A 40 °C - 3 min; 400 A 40 °C - 10 min

associated fuse rating: 200 A aM at <= 440 V; 315 A gG at <= 440 V

average impedance: 0.33 mOhm - Ith 275 A 50 Hz

[Ui] rated insulation voltage: 1000 V conforming to IEC 60947-4-1; 1500 V conforming to VDE 0110 group C

control circuit voltage limits: Operational: 0.85...1.1 Uc AC 40...400 Hz with LX9 coil; Drop-out: 0.2...0.55 Uc AC 40...400 Hz with LX9 coil; Operational: 0.85...1.1 Uc DC with LX4 coil; Drop-out: 0.15...0.2 Uc DC with LX4 coil; Operational: 85...275 V AC 50/60 Hz with LXE coil; Drop-out: 0...60 V AC 50/60 Hz with LXE coil; Operational: 85...418 V DC with LXE coil; Drop-out: 0...45 V DC with LXE coil

power dissipation per pole: 25 W AC-1; 12 W AC-3

heat dissipation: 8…9.8 W; 2.2…2.5 W

operating time: 35 ms closing for with LX9 coil; 130 ms opening for with LX9 coil; 30...40 ms closing for with LX4 coil; 30...50 ms opening for with LX4 coil; 40...80 ms closing for with LXE coil; 6...54 ms opening for with LXE coil

mounting support: Plate

standards: IEC 60947-4-1; EN 60947-1; JIS C8201-4-1; EN 60947-4-1; IEC 60947-1

product certifications: ABS; LROS (Lloyds register of shipping); RINA; CSA; CB; UL; BV; RMRoS; DNV; UKCA

connections - terminals: Power circuit: bar 2 cable(s) - busbar cross section: 25 x 3 mm; Power circuit: lugs-ring terminals 1 cable(s) 150 mm²; Power circuit: connector 1 cable(s) 150 mm²; Power circuit: bolted connection; Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible without cable end; Control circuit: screw clamp terminals 2 cable(s) 1…4 mm²flexible with cable end; Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible with cable end; Control circuit: screw clamp terminals 2 cable(s) 1…2.5 mm²solid without cable end; Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²; Control circuit: screw clamp terminals 2 cable(s) 1…4 mm²; Control circuit: screw clamp terminals 1.0 cable(s) 0.2…2.5 mm²flexible without cable end; Control circuit: screw clamp terminals 1.0 cable(s) 0.25…2.5 mm²flexible with cable end; Control circuit: screw clamp terminals 1.0 cable(s) 0.2…2.5 mm²solid without cable end

tightening torque: Power circuit: 18 N.m; Control circuit: 1.2 N.m; Control circuit: 0.6 N.m

mechanical durability: 10 Mcycles

inrush power in VA: 950…1180 VA, 40...400 Hz cos phi 0.9 (at 20 °C)with LX9 coil; 737…902 VA (at 20 °C)with LX4 coil; 280…310 VA, 50/60 Hz cos phi 0.5 (at 20 °C)with LXE coil; 270…320 VA (at 20 °C)with LXE coil

hold-in power consumption in VA: 8.9…10.9 VA, 40...400 Hz cos phi 0.9 (at 20 °C)with LX9 coil; 4.13…5.07 VA (at 20 °C)with LX4 coil; 4.5…7.0 VA, 50/60 Hz cos phi 0.5 (at 20 °C)with LXE coil; 2.5…4.0 VA (at 20 °C)with LXE coil

compatibility code: LC1F

Environment

IP degree of protection: IP2x front face with shrouds conforming to IEC 60529; IP2x front face with shrouds conforming to VDE 0106

protective treatment: TH

ambient air temperature for operation: -5…55 °C

ambient air temperature for storage: -60…80 °C

permissible ambient air temperature around the device: -40…70 °C

mechanical robustness: Vibrations contactor open: 2 Gn, 5...300 Hz; Vibrations contactor closed: 5 Gn, 5...300 Hz; Shocks contactor open: 7 Gn for 1/2 sine wave (11 ms); Shocks contactor closed: 15 Gn for 1/2 sine wave (11 ms)

height: 174 mm

width: 168.5 mm

depth: 181 mm

net weight: 5.45 kg

colour: -

Packing Units

Number of Units in Package 1: 1

Number of Units in Package 2: 12

Package 1 Height: 24 cm

Package 1 Length: 25 cm

Package 1 Weight: 4.379 kg

Package 1 Width: 27 cm

Package 2 Height: 75 cm

Package 2 Length: 80 cm

Package 2 Weight: 61.048 kg

Package 2 Width: 60 cm

Unit Type of Package 1: PCE

Unit Type of Package 2: P06

Offer Sustainability

Sustainable offer status: Green Premium product

REACh Regulation: Reference contains Substances of Very High Concern above the threshold

EU RoHS Directive: Compliant

Mercury free: Yes

RoHS exemption information: Yes

China RoHS Regulation: Product out of China RoHS scope. Substance declaration for your information

Environmental Disclosure: ENVPEP080208EN

Circularity Profile: ENVEOLI100418

WEEE: The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins

PVC free: Yes

© 2018 Alplan Kft.