Schneider-Electric
LC1BP33M22
Tariff code:
This product is discontinued.
Please contact us for possible replacement product options.
Link to the manufacturers site: LC1BP33M22 - bar-mounted contactor - TeSys LC1-BP - 3 poles - AC-3 440V 1500 A - coil 220V AC
Main
range of product: TeSys B
range: TeSys
product name: TeSys B
product or component type: Contactor
device short name: LC1BP
contactor application: Motor-heating-lighting
utilisation category: AC-4; AC-1; AC-3
control circuit type: AC
coil type: Standard
poles description: 3P
pole contact composition: 3 NO
[Ie] rated operational current: 2000 A (at <40 °C) AC AC-1 for power circuit; 1500 A (at <55 °C) AC AC-3 for power circuit
motor power kW: 425 kW at 220...230 V AC 50/60 Hz (AC-3); 670 kW at 1000 V AC 50/60 Hz (AC-3); 700 kW at 500 V AC 50/60 Hz (AC-3); 750 kW at 380...400 V AC 50/60 Hz (AC-3); 750 kW at 660...690 V AC 50/60 Hz (AC-3); 800 kW at 415 V AC 50/60 Hz (AC-3); 800 kW at 440 V AC 50/60 Hz (AC-3); 220 kW at 400 V AC 50/60 Hz (AC-4)
auxiliary contact composition: 2 NO + 2 NC
[Uc] control circuit voltage: 220 V AC 50...400 Hz
Complementary
control circuit voltage limits: Operational: 0.85...1.1 Uc at 50...400 Hz; Drop-out: 0.35...0.5 Uc at 50...400 Hz
[Ui] rated insulation voltage: 1000 V - for power circuit conforming to IEC 60158-1; 1000 V - for power circuit conforming to IEC 60947-4; 1500 V - for power circuit conforming to VDE 0110 group C
mounting mode: Fixed
mounting support: Notched mounting rails; Bar support bracket
connections - terminals: Power circuit: bars 3 x - busbar cross section: 100 x 5 mm
tightening torque: Power circuit: 35 N.m - on bars
[Ue] rated operational voltage: Power circuit: <= 1000 V AC 50/60 Hz
[Ith] conventional free air thermal current: 2000 A (at 40 °C) for power circuit
Irms rated making capacity: 15000 A at 1000 V AC for power circuit conforming to IEC 60158-1; 15000 A at 1000 V AC for power circuit conforming to IEC 60947-4
rated breaking capacity: 12000 A at 500 V for power circuit conforming to IEC 60158-1; 12000 A at 500 V for power circuit conforming to IEC 60947-4; 15000 A at 440 V for power circuit conforming to IEC 60158-1; 15000 A at 440 V for power circuit conforming to IEC 60947-4; 5000 A at 1000 V for power circuit conforming to IEC 60158-1; 5000 A at 1000 V for power circuit conforming to IEC 60947-4; 9000 A at 660...690 V for power circuit conforming to IEC 60158-1; 9000 A at 660...690 V for power circuit conforming to IEC 60947-4
associated fuse rating: 1600 A aM at <= 440 V for power circuit; 2000 A gI at <= 440 V for power circuit
average impedance: 0.13 mOhm - Ith 2000 A 50 Hz for power circuit
power dissipation per pole: 290 W AC-3 - Ith 2000 A; 520 W AC-1 - Ith 2000 A
inrush power in VA: 1300 VA
hold-in power consumption in VA: 31 VA 50/60 Hz
operating time: 100...150 ms closing; 50...100 ms opening
mechanical durability: 1200000 cycles
maximum operating rate: 120 cyc/h 55 °C
height: 490 mm
width: 790 mm
depth: 475 mm
net weight: 94 kg
compatibility code: LC1BP
Environment
standards: NF C 63-110; BS 5424; VDE 0660; IEC 60158-1; IEC 60947-4
product certifications: RINA; CSA; BV
protective treatment: TC; TH
ambient air temperature for operation: -5…55 °C
ambient air temperature for storage: -60…80 °C
operating altitude: 3000 m without derating
Offer Sustainability
REACh Regulation: Free of Substances of Very High Concern above the threshold
EU RoHS Directive: Compliant
Mercury free: Yes
RoHS exemption information: Yes
China RoHS Regulation: Product out of China RoHS scope. Substance declaration for your information
WEEE: The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
© 2018 Alplan Kft.