LC1BP33M22

bar-mounted contactor - TeSys LC1-BP - 3 poles - AC-3 440V 1500 A - coil 220V AC
Barcode: 3389110103076
Tariff code:

This product is discontinued.

Please contact us for possible replacement product options.

Link to the manufacturers site: LC1BP33M22 - bar-mounted contactor - TeSys LC1-BP - 3 poles - AC-3 440V 1500 A - coil 220V AC

Main

range of product: TeSys B

range: TeSys

product name: TeSys B

product or component type: Contactor

device short name: LC1BP

contactor application: Motor-heating-lighting

utilisation category: AC-4; AC-1; AC-3

control circuit type: AC

coil type: Standard

poles description: 3P

pole contact composition: 3 NO

[Ie] rated operational current: 2000 A (at <40 °C) AC AC-1 for power circuit; 1500 A (at <55 °C) AC AC-3 for power circuit

motor power kW: 425 kW at 220...230 V AC 50/60 Hz (AC-3); 670 kW at 1000 V AC 50/60 Hz (AC-3); 700 kW at 500 V AC 50/60 Hz (AC-3); 750 kW at 380...400 V AC 50/60 Hz (AC-3); 750 kW at 660...690 V AC 50/60 Hz (AC-3); 800 kW at 415 V AC 50/60 Hz (AC-3); 800 kW at 440 V AC 50/60 Hz (AC-3); 220 kW at 400 V AC 50/60 Hz (AC-4)

auxiliary contact composition: 2 NO + 2 NC

[Uc] control circuit voltage: 220 V AC 50...400 Hz

Complementary

control circuit voltage limits: Operational: 0.85...1.1 Uc at 50...400 Hz; Drop-out: 0.35...0.5 Uc at 50...400 Hz

[Ui] rated insulation voltage: 1000 V - for power circuit conforming to IEC 60158-1; 1000 V - for power circuit conforming to IEC 60947-4; 1500 V - for power circuit conforming to VDE 0110 group C

mounting mode: Fixed

mounting support: Notched mounting rails; Bar support bracket

connections - terminals: Power circuit: bars 3 x - busbar cross section: 100 x 5 mm

tightening torque: Power circuit: 35 N.m - on bars

[Ue] rated operational voltage: Power circuit: <= 1000 V AC 50/60 Hz

[Ith] conventional free air thermal current: 2000 A (at 40 °C) for power circuit

Irms rated making capacity: 15000 A at 1000 V AC for power circuit conforming to IEC 60158-1; 15000 A at 1000 V AC for power circuit conforming to IEC 60947-4

rated breaking capacity: 12000 A at 500 V for power circuit conforming to IEC 60158-1; 12000 A at 500 V for power circuit conforming to IEC 60947-4; 15000 A at 440 V for power circuit conforming to IEC 60158-1; 15000 A at 440 V for power circuit conforming to IEC 60947-4; 5000 A at 1000 V for power circuit conforming to IEC 60158-1; 5000 A at 1000 V for power circuit conforming to IEC 60947-4; 9000 A at 660...690 V for power circuit conforming to IEC 60158-1; 9000 A at 660...690 V for power circuit conforming to IEC 60947-4

associated fuse rating: 1600 A aM at <= 440 V for power circuit; 2000 A gI at <= 440 V for power circuit

average impedance: 0.13 mOhm - Ith 2000 A 50 Hz for power circuit

power dissipation per pole: 290 W AC-3 - Ith 2000 A; 520 W AC-1 - Ith 2000 A

inrush power in VA: 1300 VA

hold-in power consumption in VA: 31 VA 50/60 Hz

operating time: 100...150 ms closing; 50...100 ms opening

mechanical durability: 1200000 cycles

maximum operating rate: 120 cyc/h 55 °C

height: 490 mm

width: 790 mm

depth: 475 mm

net weight: 94 kg

compatibility code: LC1BP

Environment

standards: NF C 63-110; BS 5424; VDE 0660; IEC 60158-1; IEC 60947-4

product certifications: RINA; CSA; BV

protective treatment: TC; TH

ambient air temperature for operation: -5…55 °C

ambient air temperature for storage: -60…80 °C

operating altitude: 3000 m without derating

Offer Sustainability

REACh Regulation: Free of Substances of Very High Concern above the threshold

EU RoHS Directive: Compliant

Mercury free: Yes

RoHS exemption information: Yes

China RoHS Regulation: Product out of China RoHS scope. Substance declaration for your information

WEEE: The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins