Schneider-Electric
XY2CH13290H29

EMERGENCY STOP TRIP WIRE SWITCH WITHOUT
Barcode: 3389119074025
Tariff code: 8536508090

This product is discontinued.

Please contact us for possible replacement product options.

Link to the manufacturers site: XY2CH13290H29 - EMERGENCY STOP TRIP WIRE SWITCH WITHOUT

Main

Range of produc: Telemecanique Emergency stop rope pull switches XY2C

Product or component type: Latching emergency stop rope pull switch

Device short name: XY2CH

Housing colour: Red RAL 3000

Overvoltage category: Class I conforming to EN/IEC 61140; Class I conforming to NF C 20-030

Complementary

Local signalling: Without pilot light

Number of cables: 1

Trigger cable maximum length: 30 m

body material: Zamak

Cover material: Stainless steel

Reset: By booted push-button

Contacts type and composition: 2 NC + 1 NO

contact operation: Slow-break

Trigger cable anchor point: RH or LH side

Connections - terminals: Screw clamp terminal, 1 x 0.34...1 x 1 mm²; Screw clamp terminal, 1 x 0.34...2 x 0.75 mm²

Tightening torque: 0.8…1.2 N.m

Cable entry number: 3 tapped entry for ISO M20 cable gland

Safety level: Can reach PL = e with the appropriate monitoring system and correctly wired conforming to EN/ISO 13849-1; Can reach category 4 with the appropriate monitoring system and correctly wired conforming to EN/ISO 13849-1; Can reach SIL 3 with the appropriate monitoring system and correctly wired conforming to EN/IEC 61508

Safety reliability data: B10d = 4000000 conforming to IEC 60947-5-5 value given for a life time of 20 years limited by mechanical or contact wear

Marking: CE

Mechanical durability: 800000 cycles

Distance between cable supports: 5 m

[Ie] rated operational current: 0.1 A at 250 V, DC-13, R300 conforming to EN/IEC 60947-5-1 appendix A; 1.5 A at 240 V, AC-15, B300 conforming to EN/IEC 60947-5-1 appendix A

[Ithe] conventional enclosed thermal current: 6 A

[Ui] rated insulation voltage: 400 V (pollution degree 3) conforming to EN/IEC 60947-1; 300 V conforming to UL 508

[Uimp] rated impulse withstand voltage: 4 kV conforming to EN/IEC 60947-1

Positive opening: With conforming to EN/IEC 60947-5-1

Maximum resistance across terminals: 25 MOhm conforming to EN/IEC 60255-7 category 3; 25 MOhm conforming to NF C 93-050 method A

Short-circuit protection: 6 A cartridge fuse type gG conforming to EN/IEC 60269

Terminals description ISO n°1: (31-32)NC; (21-22)NC; (13-14)NO

Net weight: 0.865 kg

Compatibility code: XY2CH

Environment

Standards: EN/IEC 60947-5-1; EN/IEC 60204-1; EN/IEC 60947-5-5; Machinery directive 2006/42/EC; Work equipment directive 2009/104/EC; EN/ISO 13850

Product certifications: UL category NISD emergency stop devices; CCC

Protective treatment: TC

ambient air temperature for operation: -25…70 °C

Ambient air temperature for storage: -40…70 °C

Vibration resistance: 10 gn (f= 10…150 Hz) conforming to EN/IEC 60068-2-6

Shock resistance: 50 gn 11 ms conforming to EN/IEC 60068-2-27

IP degree of protection: IP65 conforming to IEC 60529

Packing Units

Unit Type of Package 1: PCE

Number of Units in Package 1: 1

Package 1 Height: 8.000 cm

Package 1 Width: 9.200 cm

Package 1 Length: 19.600 cm

Package 1 Weight: 1.015 kg

Unit Type of Package 2: S03

Number of Units in Package 2: 10

Package 2 Height: 30.000 cm

Package 2 Width: 30.000 cm

Package 2 Length: 40.000 cm

Package 2 Weight: 10.685 kg

Unit Type of Package 3: P06

Number of Units in Package 3: 80

Package 3 Height: 75.000 cm

Package 3 Width: 60.000 cm

Package 3 Length: 80.000 cm

Package 3 Weight: 95.484 kg

Offer Sustainability

Sustainable offer status: Green Premium product

REACh Regulation: Reference contains Substances of Very High Concern above the threshold

EU RoHS Directive: Pro-active compliance (Product out of EU RoHS legal scope)

Mercury free: Yes

RoHS exemption information: Yes

Environmental Disclosure: ENVPEP111159EN

Circularity Profile: N/A