Skip to main content

Schneider-Electric
XY2CE2C250TK

TRIP WIRE SWITCH
Barcode: 3389110959383
Tariff code: 8536508090

This product is discontinued.

Please contact us for possible replacement product options.

Link to the manufacturers site: XY2CE2C250TK - TRIP WIRE SWITCH

Main

Range of produc: Telemecanique Emergency stop rope pull switches XY2C

Product or component type: Latching emergency stop rope pull switch

Device short name: XY2CE

Housing colour: Red RAL 3000

Overvoltage category: Class I conforming to EN/IEC 61140; Class I conforming to NF C 20-030

Complementary

Local signalling: Without pilot light

Number of cables: 1

Trigger cable maximum length: 50 m

Bellow material: Nitril

body material: Zamak

Cover material: Stainless steel

Reset: By booted push-button

Contacts type and composition: 1 NC + 1 NO

contact operation: Slow-break

Trigger cable anchor point: LH side

Connections - terminals: Screw clamp terminal, 1 x 0.5...2 x 1.5 mm²

Tightening torque: 0.8…1.2 N.m

Cable entry number: 3 tapped entry for Pg 13.5 cable gland

Safety level: Can reach PL = e with the appropriate monitoring system and correctly wired conforming to EN/ISO 13849-1; Can reach category 4 with the appropriate monitoring system and correctly wired conforming to EN/ISO 13849-1; Can reach SIL 3 with the appropriate monitoring system and correctly wired conforming to EN/IEC 61508

Safety reliability data: B10d = 300000 conforming to IEC 60947-5-5 value given for a life time of 20 years limited by mechanical or contact wear

Marking: CE

Mechanical durability: 60000 cycles

Distance between cable supports: 5 m

[Ie] rated operational current: 3 A at 240 V, AC-15, A300 conforming to EN/IEC 60947-5-1 appendix A; 0.27 A at 250 V, DC-13, Q300 conforming to EN/IEC 60947-5-1 appendix A

[Ithe] conventional enclosed thermal current: 10 A

[Ui] rated insulation voltage: 500 V (pollution degree 3) conforming to EN/IEC 60947-1; 300 V conforming to UL 508; 300 V conforming to CSA C22.2 No 14

[Uimp] rated impulse withstand voltage: 6 kV conforming to EN/IEC 60947-1

Positive opening: With conforming to EN/IEC 60947-5-1

Maximum resistance across terminals: 25 MOhm conforming to EN/IEC 60255-7 category 3; 25 MOhm conforming to NF C 93-050 method A

Short-circuit protection: 10 A cartridge fuse type gG conforming to EN/IEC 60269

Terminals description ISO n°1: (13-14)NO; (21-22)NC

Net weight: 1.45 kg

Compatibility code: XY2CE

Environment

Standards: UL 508; CSA C22.2 No 14; EN/IEC 60947-5-1; Work equipment directive 2009/104/EC; EN/ISO 13850; EN/IEC 60204-1; Machinery directive 2006/42/EC; EN/IEC 60947-5-5

Product certifications: UL category NISD emergency stop devices; CSA; CCC

Protective treatment: TC

ambient air temperature for operation: -40…70 °C

Ambient air temperature for storage: -40…70 °C

Vibration resistance: 10 gn (f= 10…300 Hz) conforming to EN/IEC 60068-2-6

Shock resistance: 50 gn 11 ms conforming to EN/IEC 60068-2-27

IP degree of protection: IP66 conforming to IEC 60529

Packing Units

Unit Type of Package 1: PCE

Number of Units in Package 1: 1

Package 1 Height: 9.0 cm

Package 1 Width: 15.0 cm

Package 1 Length: 20.0 cm

Package 1 Weight: 1.535 kg

Offer Sustainability

Sustainable offer status: Green Premium product

REACh Regulation: Reference contains Substances of Very High Concern above the threshold

EU RoHS Directive: Pro-active compliance (Product out of EU RoHS legal scope)

Mercury free: Yes

RoHS exemption information: Yes

Environmental Disclosure: ENVPEP111159EN

Circularity Profile: N/A

© 2018 Alplan Kft.