Skip to main content

Schneider-Electric
XACD21P3241

pendant station XAC-D - 1 rocker lever
Barcode: 3389110656091
Tariff code:

This product is discontinued.

Please contact us for possible replacement product options.

Link to the manufacturers site: XACD21P3241 - pendant station XAC-D - 1 rocker lever

Main

range of product: Harmony XAC

product or component type: Pendant control station

device short name: XACD

Complementary

control station type: Double insulated

enclosure material: Polypropylene

control type: Intuitive

electrical circuit type: Power circuit

enclosure type: Complete ready for use

control station application: Control of 2-speed hoist motor

motor starter type: Reversing

control station composition: 1 2-directional button

control button type: First direction button 1 NO (brake) 2-pole raise, slow-fast; Second direction button 1 NO (brake) 2-pole lower, slow-fast

product compatibility: XEDS3241 for reversing operation

mechanical interlocking: With mechanical interlocking

control station colour: Yellow

connections - terminals: Screw clamp terminals, 1 x 2.5 mm² with or without cable end; Screw clamp terminals, 2 x 1.5 mm² with or without cable end

standards: UL 508; CSA C22.2 No 14; EN/IEC 60204-32; EN/IEC 60947-5-1

protective treatment: TH

ambient air temperature for operation: -25…70 °C

ambient air temperature for storage: -40…70 °C

vibration resistance: 15 gn (f= 10…500 Hz) conforming to IEC 60068-2-6

shock resistance: 70 gn conforming to IEC 60068-2-27

overvoltage category: Class II conforming to IEC 61140

IP degree of protection: IP65 conforming to IEC 60529

IK degree of protection: IK08 conforming to EN 50102

mechanical durability: 3000000 cycles

cable entry: Rubber sleeve with stepped entry 7…18 mm

[Ithe] conventional enclosed thermal current: 16 A

[Ui] rated insulation voltage: 500 V (pollution degree 3) conforming to IEC 60947-1

[Uimp] rated impulse withstand voltage: 6 kV conforming to IEC 60947-1

contact operation: Snap action

operating force: 31 N

short-circuit protection: 6 A fuse protection by cartridge fuse type aM

rated operational power in W: 2200 W AC-3 at 400 V conforming to IEC 60947-3 appendix A; 2200 W AC-4 at 400 V conforming to IEC 60947-3 appendix A

electrical durability: 1000000 cycles AC-3, 2200 W at 400 V, operating rate <10 cyc/mn, load factor = 0.4 conforming to IEC 60947-3 appendix A; 1000000 cycles AC-4, 2200 W at 400 V, operating rate <10 cyc/mn, load factor = 0.4 conforming to IEC 60947-3 appendix A

terminals description ISO n°1: (15-16)NO; (R1-R2)RP; (1-2)P; (11-12)P; (7-8)P; (5-6)P; (13-14)NO; (R3-R4)RP; (3-4)P; (9-10)P

terminal identifier: (13-14)NO; (11-12)NC

net weight: 0.355 kg

Offer Sustainability

REACh Regulation: Free of Substances of Very High Concern above the threshold

REACh free of SVHC: Yes

EU RoHS Directive: Pro-active compliance (Product out of EU RoHS legal scope)

Toxic heavy metal free: Yes

Mercury free: Yes

RoHS exemption information: Yes

China RoHS Regulation: X

WEEE: The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins

© 2018 Alplan Kft.