Skip to main content

Schneider-Electric
TM3SAK6R

SAFETY MODULE FOR PLC TM2xx, 3 FUNCTIONS, CAT4, SCREW TERMINALS
Net discounted price 281.35 EUR
Available when ordered (delivery time: 8 working day(s))
Barcode: 3606485393032
Tariff code: 8536419089

Link to the manufacturers site: TM3SAK6R - SAFETY MODULE FOR PLC TM2xx, 3 FUNCTIONS, CAT4, SCREW TERMINALS

Main

Range of product: Modicon TM3 Safety

product or component type: Safety module

Device short name: TM3SAK

Safety module application: For emergency stop, switch, sensing mat/edges or safety light curtain monitoring

Function of module: Emergency stop monitoring 1-channel wiring; Emergency stop monitoring 2-channel wiring; Monitoring of a movable guard with 2 switches and automatic start; Monitoring of a movable guard; Multiple emergency stop monitoring 2-channel wiring; Proximity sensor monitoring PNP/PNP; Proximity sensor monitoring PNP/NPN; Sensing mat and edges monitoring; Monitoring of electro-sensitive protection equipment (ESPE) PNP/PNP; Monitoring of electro-sensitive protection equipment (ESPE) PNP/NPN

Safety level: Can reach PL e/category 4 conforming to ISO 13849-1: 2008; Can reach PL e/category 4 conforming to ISO 13849-2: 2012; Can reach SILCL 3 conforming to IEC 62061: 2005; Can reach SIL 3 conforming to IEC 61508: 2010

Complementary

Safety reliability data: DC = 95 % conforming to ISO 13849-1; PFHd = 5E-9 1/h conforming to IEC 61508-1 1 operation/hour DC-13 24 V DC, <4 A; PFHd = 30E-9 1/h conforming to IEC 61508-1 60 operations/hour DC-13 24 V DC, <1 A; MTTFd = 500 years conforming to ISO 13849-1 1 operation/hour DC-13 24 V DC, <4 A; MTTFd = 85 years conforming to ISO 13849-1 60 operations/hour DC-13 24 V DC, <1 A; SFF = 95 % conforming to IEC 61508-1; HFT = 1 conforming to IEC 61508-1; Type = A conforming to IEC 61508-1

Synchronisation time between inputs: Unlimited; 2 or 4 s depending of wiring configurable by software

Connections - terminals: Captive screw clamp terminals, removable terminal block 1 x 0.2...1 x 2.5 mm² flexible without cable end 13-14, 23-24, 33-34; Captive screw clamp terminals, removable terminal block 1 x 0.2...1 x 2.5 mm² solid without cable end 13-14, 23-24, 33-34; Captive screw clamp terminals, removable terminal block 1 x 0.25...1 x 2.5 mm² flexible with cable end, with bezel 13-14, 23-24, 33-34; Captive screw clamp terminals, removable terminal block 1 x 0.25...1 x 2.5 mm² flexible with cable end, without bezel 13-14, 23-24, 33-34; Captive screw clamp terminals, removable terminal block 2 x 0.2...2 x 1.5 mm² flexible without cable end 13-14, 23-24, 33-34; Captive screw clamp terminals, removable terminal block 2 x 0.2...2 x 1.5 mm² solid without cable end 13-14, 23-24, 33-34; Captive screw clamp terminals, removable terminal block 2 x 0.25...2 x 1 mm² flexible with cable end, without bezel 13-14, 23-24, 33-34; Captive screw clamp terminals, removable terminal block 2 x 0.5...2 x 1.5 mm² flexible with cable end, with double bezel 13-14, 23-24, 33-34; Captive screw clamp terminals, removable terminal block 1 x 0.14...1 x 1.5 mm² flexible without cable end other terminals; Captive screw clamp terminals, removable terminal block 1 x 0.14...1 x 1.5 mm² solid without cable end other terminals; Captive screw clamp terminals, removable terminal block 1 x 0.25...1 x 0.5 mm² flexible with cable end, with bezel other terminals; Captive screw clamp terminals, removable terminal block 1 x 0.25...1 x 1.5 mm² flexible with cable end, without bezel other terminals; Captive screw clamp terminals, removable terminal block 2 x 0.14...2 x 0.5 mm² flexible without cable end other terminals; Captive screw clamp terminals, removable terminal block 2 x 0.14...2 x 0.75 mm² solid without cable end other terminals; Captive screw clamp terminals, removable terminal block 2 x 0.25...2 x 0.34 mm² flexible with cable end, without bezel other terminals; Captive screw clamp terminals, removable terminal block 2 x 0.5 mm² flexible with cable end, with double bezel other terminals

Output type: Relay instantaneous opening, 3 NO circuit(s), potential free

Number of safety circuits: 3 NO for relay instantaneous opening

Maximum switching voltage: 230 V utilisation category AC-15 at 50 Hz (relay instantaneous opening); 24 V utilisation category DC-13 (relay instantaneous opening)

[Us] rated supply voltage: 24 V - 15...20 % DC

Power consumption in W: 0.2 W at 5 V DC; 3.6 W at 24 V DC

Input protection type: Internal, electronic

[Uc] control circuit voltage: 24 V DC

Maximum cable distance between devices: 30 m

Breaking capacity: 360 VA holding AC-15 B300 relay output; 3600 VA inrush AC-15 B300 relay output

Breaking capacity: 4 A 24 V 50 ms DC-13 relay output

Output thermal current: 6 A per relay for relay output

[Ith] conventional free air thermal current: 18 A

Associated fuse rating: 4 A gG or gL for relay output conforming to IEC 60947-5-1; 6 A fast blow for relay output conforming to IEC 60947-5-1

Minimum output current: 10 mA for relay output

Output voltage: 10 V relay output

Maximum response time on input open: 40 ms

[Ui] rated insulation voltage: 300 V (pollution degree 2) conforming to IEC 60647-5-1

[Uimp] rated impulse withstand voltage: 4 kV overvoltage category III conforming to IEC 60647-5-1

Current consumption: 100 mA at 24 V DC external supply

Local signalling: 8 LEDs (green/red) for user

Electrical connection: Screw terminal

Product compatibility: Safety light curtains conforming to EN/IEC 61496-1 (type 4); Sensing mat/edges conforming to EN 1760-1

Standards: ISO 13849-1:2008; ISO 13849-2:2012; IEC 62061:2005; IEC 61508:2010; IEC 60947-5-1:2010; IEC 61131-2:2007; IEC 60204-1:2005; IEC 60204-1:2009/A1; IEC 61010-1:2010; EN 50581:2012

Product certifications: TÜV; UL 61010-2-201; EAC; CSA Haz Loc Class 1 Division 2 (pending); CSA 61010-2-201 (pending); RCM; ANSI Haz Loc Class 1 Division 2 (pending)

Marking: UL; CE; RCM; EAC; EFUP 10; TÜV; CSA

Electromagnetic compatibility: Electrostatic discharge immunity test - test level: 8 kV (air discharge) conforming to IEC 61000-4-2; Electrostatic discharge immunity test - test level: 6 kV (contact discharge) conforming to IEC 61000-4-2; Susceptibility to electromagnetic fields - test level: 10 V/m (80 MHz to 1 GHz) conforming to IEC 61000-4-3; Susceptibility to electromagnetic fields - test level: 3 V/m (1.4 GHz...2 GHz) conforming to IEC 61000-4-3; Susceptibility to electromagnetic fields - test level: 1 V/m (2 GHz...3 GHz) conforming to IEC 61000-4-3; Magnetic field at power frequency - test level: 30 A/m (50...60 Hz) conforming to IEC 61000-4-8; Electrical fast transient/burst immunity test - test level: 3 kV (power lines (DC)) conforming to IEC 61000-4-4; Electrical fast transient/burst immunity test - test level: 2 kV (I/O) conforming to IEC 61000-4-4; 1.2/50 µs shock waves immunity test - test level: 1 kV (power lines (DC)) conforming to IEC 61000-4-5; Conducted RF disturbances - test level: 10 V (0.15...80 MHz) conforming to IEC 61000-4-6; Radiated emission - test level: 40 dBµV/m class A (24 V) conforming to IEC 55011; Radiated emission - test level: 47 dBµV/m class A (24 V) conforming to IEC 55011

Mounting support: Top hat type TH35-7.5 rail conforming to IEC 60715; Top hat type TH35-15 rail conforming to IEC 60715; wall mount using attached fasteners

Height: 94 mm

Depth: 73 mm

Width: 43.7 mm

Net weight: 0.19 kg

Environment

Standards: IEC 60947-1; IEC 60204-1; EN 1088/ISO 14119; IEC 60947-5-1; ISO 13850

Resistance to electrostatic discharge: 8 kV in air conforming to IEC 61000-4-2; 6 kV on contact conforming to IEC 61000-4-2

Resistance to electromagnetic fields: 10 V/m 80 MHz...1 GHz conforming to IEC 61000-4-3; 3 V/m 1.4 GHz...2 GHz conforming to IEC 61000-4-3; 1 V/m 2 GHz...3 GHz conforming to IEC 61000-4-3

Resistance to magnetic fields: 30 A/m 50/60 Hz conforming to IEC 61000-4-8

Resistance to fast transients: 3 kV for power lines (DC) (DC) conforming to IEC 61000-4-4; 2 kV for I/O lines conforming to IEC 61000-4-4

Surge withstand: 1 kV power lines (DC) differential mode conforming to IEC 61000-4-5 DC; 1 kV power lines (DC) common mode conforming to IEC 61000-4-5 DC

Resistance to conducted disturbances: 10 V 0.15...80 MHz conforming to IEC 61000-4-6

Electromagnetic emission: Radiated emissions - test level: 50 dBµV/m class A ( 24 V DC) at 30…230 Hz conforming to IEC 61131-3; Radiated emissions - test level: 57 dBµV/m class A ( 24 V DC) at 230…1000 Hz conforming to IEC 61131-3

Ambient air temperature for operation: -10…55 °C horizontal installation

Ambient air temperature for storage: -25…70 °C

Relative humidity: 10…95 %, without condensation (in operation); 10…95 %, without condensation (in storage)

IP degree of protection: IP20 (terminals) conforming to IEC 60529

Pollution degree: 2

Operating altitude: 0...2000 m

Storage altitude: 0…3000 m

Vibration resistance: +/- 3.5 mm (f= 5…150 Hz) conforming to IEC 60068-2-6

Shock resistance: 15 gn for 11 ms conforming to IEC 60068-2-27

Mechanical robustness: Bumps 6 ms 300 shocks (25 gn) conforming to IEC 60068-2-27

Packing Units

Unit Type of Package 1: PCE

Number of Units in Package 1: 1

Package 1 Height: 7.500 cm

Package 1 Width: 10.600 cm

Package 1 Length: 12.500 cm

Package 1 Weight: 287.000 g

Unit Type of Package 2: S03

Number of Units in Package 2: 18

Package 2 Height: 30.000 cm

Package 2 Width: 30.000 cm

Package 2 Length: 40.000 cm

Package 2 Weight: 5.513 kg

Offer Sustainability

Sustainable offer status: Green Premium product

REACh Regulation: Reference contains Substances of Very High Concern above the threshold

EU RoHS Directive: Pro-active compliance (Product out of EU RoHS legal scope)

Mercury free: Yes

China RoHS Regulation: X

RoHS exemption information: Yes

Environmental Disclosure: ENVPEP1403010EN

Circularity Profile: ENVEOLI1403010EN

WEEE: The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins

© 2018 Alplan Kft.